Development and Validation of a Clinical CT System Simulator

被引:1
|
作者
Tunissen, S. A. M. [1 ]
Oostveen, L. J. [1 ]
Moriakov, N. [1 ,2 ]
Teuwen, J. [1 ,2 ]
Michielsen, K. [1 ]
Smit, E. J. [1 ]
Sechopoulos, I [1 ,3 ,4 ]
机构
[1] Radboudumc, Dept Med Imaging, Nijmegen, Netherlands
[2] Netherlands Canc Inst, AI Oncol, Amsterdam, Netherlands
[3] Dutch Expert Ctr Screening LRCB, Nijmegen, Netherlands
[4] Univ Twente, Tech Med Ctr, Enschede, Netherlands
关键词
CT; computer simulations; system characterization;
D O I
10.1117/12.2611323
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Many advanced reconstruction and image processing methods are being developed with the aim of improving image quality in CT. Development and testing of these methods is aided by the ability to simulate realistic images, to both control the acquisition process and be able to use digital phantoms with known ground truth. Therefore, in this work, we present a method to simulate realistic scanner-specific sinograms from digital phantoms. For this, a series of measurements was conducted on a clinical CT system to characterize resolution loss, noise characteristics, and the exposure-to-detector output relationship. These measurements were used to develop a simulation pipeline, which involves raytracing of a digital phantom, taking into account the focal spot size and gantry rotation, followed by the use of Lambert's Law to determine the amount of energy arriving at each detector element. The spectrum for the specific tube voltage and current was modeled using previously published spectral models. The resulting sinogram was then corrupted, by applying the measured detector Modulation Transfer Function (MTF), and adding noise based on the Noise Power Spectrum (NPS) and mean-variance relationship. Simulator results were compared to those acquired with the CT system in our clinic, showing an average difference of 2.1% in the off-center MTF magnitude, 4.6% in normalized NPS magnitude and only 6 and 5 Hounsfield Units (HU) difference in the voxel values for water and air, respectively. The developed simulator seems capable of generating realistic CT images, which can help researchers develop and test their algorithms.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Development and validation of multiphysics PWR core simulator KANT
    Oh, Taesuk
    Jeong, Yunseok
    Khale, Husam
    Kim, Yonghee
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (06) : 2230 - 2245
  • [32] New metabolic lung simulator: Development, description, and validation
    Rosenbaum A.
    Kirby C.
    Breen P.H.
    Journal of Clinical Monitoring and Computing, 2007, 21 (2) : 71 - 82
  • [33] Development and validation of a low-cost tracheostomy simulator
    Temperly, Kassio Silva
    Yaegashi, Cecilia Hissai
    de Lara da Silva, Ana Maria
    Novak, Eduardo Murilo
    SCIENTIA MEDICA, 2018, 28 (01)
  • [34] CLINICAL-EVALUATION OF A CT-BASED SIMULATOR
    SMITH, RM
    MEDICAL PHYSICS, 1985, 12 (04) : 538 - 538
  • [35] Development and clinical validation of a grading system for pituitary adenoma consistency
    Rutkowski, Martin J.
    Chang, Ki-Eun
    Cardinal, Tyler
    Du, Robin
    Tafreshi, Ali R.
    Donoho, Daniel A.
    Brunswick, Andrew
    Micko, Alexander
    Liu, Chia-Shang J.
    Shiroishi, Mark S.
    Carmichael, John D.
    Zada, Gabriel
    JOURNAL OF NEUROSURGERY, 2021, 134 (06) : 1800 - 1807
  • [36] Description and validation of a computer based refrigeration system simulator
    Eames, I. W.
    Brown, T.
    Evans, J. A.
    Maidment, G. G.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2012, 85 : 53 - 63
  • [38] DEVELOPMENT OF FARM OPERATION SYSTEM SIMULATOR
    ISHIZUKA, N
    AGRICULTURAL ENGINEERING, VOLS 1-4: LAND AND WATER USE, AGRICULTURAL BUILDINGS, AGRICULTURAL MECHANISATION, POWER, PROCESSING AND SYSTEMS, 1989, : 2633 - 2638
  • [39] Development of Hemodialysis Accident Simulator System
    Yoshiaki, Nishite
    Shingo, Takesawa
    Hiroshi, Tobata
    Vee, David
    BLOOD PURIFICATION, 2009, 28 (04) : 303 - 304
  • [40] Development of IR imaging system simulator
    Xiang, Xinglang
    He, Guojing
    Dong, Weike
    Dong, Lu
    SECOND INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2017, 10256