Development and validation of a low dose simulator for computed tomography

被引:32
|
作者
Joemai, R. M. S. [1 ,2 ]
Geleijns, J. [2 ]
Veldkamp, W. J. H. [2 ]
机构
[1] Leiden Univ, Dept Radiol, Med Ctr, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Dept Radiol, Med Ctr, NL-2333 ZA Leiden, Netherlands
关键词
Computed tomography; X-ray; Radiation; Physics; Computer simulation; Noise; IMAGE QUALITY; CT; REDUCTION; COLONOGRAPHY; FEASIBILITY;
D O I
10.1007/s00330-009-1617-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To develop and validate software for facilitating observer studies on the effect of radiation exposure on the diagnostic value of computed tomography (CT). A low dose simulator was developed which adds noise to the raw CT data. For validation two phantoms were used: a cylindrical test object and an anthropomorphic phantom. Images of both were acquired at different dose levels by changing the tube current of the acquisition (500 mA to 20 mA in five steps). Additionally, low dose simulations were performed from 500 mA downwards to 20 mA in the same steps. Noise was measured within the cylindrical test object and in the anthropomorphic phantom. Finally, noise power spectra (NPS) were measured in water. The low dose simulator yielded similar image quality compared with actual low dose acquisitions. Mean difference in noise over all comparisons between actual and simulated images was 5.7 +/- 4.6% for the cylindrical test object and 3.3 +/- 2.6% for the anthropomorphic phantom. NPS measurements showed that the general shape and intensity are similar. The developed low dose simulator creates images that accurately represent the image quality of acquisitions at lower dose levels and is suitable for application in clinical studies.
引用
收藏
页码:958 / 966
页数:9
相关论文
共 50 条
  • [1] Development and validation of a low dose simulator for computed tomography
    R. M. S. Joemai
    J. Geleijns
    W. J. H. Veldkamp
    European Radiology, 2010, 20 : 958 - 966
  • [2] Validation of a Low Dose Simulation Technique for Computed Tomography Images
    Muenzel, Daniela
    Koehler, Thomas
    Brown, Kevin
    Zabic, Stanislav
    Fingerle, Alexander A.
    Waldt, Simone
    Bendik, Edgar
    Zahel, Tina
    Schneider, Armin
    Dobritz, Martin
    Rummeny, Ernst J.
    Noel, Peter B.
    PLOS ONE, 2014, 9 (09):
  • [3] Dose Optimization for Computed Tomography Localizer Radiographs for Low-Dose Lung Computed Tomography Examinations
    Schmidt, Bernhard T.
    Hupfer, Martin
    Saltybaeva, Natalia
    Kolditz, Daniel
    Kalender, Willi A.
    INVESTIGATIVE RADIOLOGY, 2017, 52 (02) : 81 - 86
  • [4] LOW-DOSE COMPUTED-TOMOGRAPHY
    GHOLKAR, A
    HART, CW
    MOTT, D
    GILLESPIE, JE
    ISHERWOOD, I
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 773 - 773
  • [5] Validation for measurements of skeletal muscle areas using low-dose chest computed tomography
    Lim, Woo Hyeon
    Park, Chang Min
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Validation for measurements of skeletal muscle areas using low-dose chest computed tomography
    Woo Hyeon Lim
    Chang Min Park
    Scientific Reports, 12
  • [7] Impact of Low-Dose Computed Tomography on Computed Tomography Orders and Scan Length
    Simmons, Curtis
    Milburn, James
    OCHSNER JOURNAL, 2019, 19 (04): : 303 - 308
  • [8] Dosimetry for low-dose computed tomography of the chest
    Lenzen, H
    Roos, N
    Diederich, S
    Meier, N
    RADIOLOGE, 1996, 36 (06): : 483 - 488
  • [9] Low-dose computed tomography in pediatric radiology
    Salamipour, H
    Bramson, RT
    Anupindi, SA
    Gray, JE
    Hamberg, LM
    RADIOLOGY, 2001, 221 : 247 - 247
  • [10] Low radiation dose in computed tomography: the role of iodine
    Aschoff, Andrik J.
    Catalano, Carlo
    Kirchin, Miles A.
    Krix, Martin
    Albrecht, Thomas
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076):