Development and validation of a low dose simulator for computed tomography

被引:32
|
作者
Joemai, R. M. S. [1 ,2 ]
Geleijns, J. [2 ]
Veldkamp, W. J. H. [2 ]
机构
[1] Leiden Univ, Dept Radiol, Med Ctr, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ, Dept Radiol, Med Ctr, NL-2333 ZA Leiden, Netherlands
关键词
Computed tomography; X-ray; Radiation; Physics; Computer simulation; Noise; IMAGE QUALITY; CT; REDUCTION; COLONOGRAPHY; FEASIBILITY;
D O I
10.1007/s00330-009-1617-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To develop and validate software for facilitating observer studies on the effect of radiation exposure on the diagnostic value of computed tomography (CT). A low dose simulator was developed which adds noise to the raw CT data. For validation two phantoms were used: a cylindrical test object and an anthropomorphic phantom. Images of both were acquired at different dose levels by changing the tube current of the acquisition (500 mA to 20 mA in five steps). Additionally, low dose simulations were performed from 500 mA downwards to 20 mA in the same steps. Noise was measured within the cylindrical test object and in the anthropomorphic phantom. Finally, noise power spectra (NPS) were measured in water. The low dose simulator yielded similar image quality compared with actual low dose acquisitions. Mean difference in noise over all comparisons between actual and simulated images was 5.7 +/- 4.6% for the cylindrical test object and 3.3 +/- 2.6% for the anthropomorphic phantom. NPS measurements showed that the general shape and intensity are similar. The developed low dose simulator creates images that accurately represent the image quality of acquisitions at lower dose levels and is suitable for application in clinical studies.
引用
收藏
页码:958 / 966
页数:9
相关论文
共 50 条
  • [21] Computed tomography evaluation of the normal appendix: Comparison of low-dose and standard-dose unenhanced helical computed tomography
    Karabulut, Nevzat
    Boyaci, Nurefsan
    Yagci, Baki
    Herek, Duygu
    Kiroglu, Yimaz
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (05) : 732 - 740
  • [22] Comparison of Low-Dose Computed Tomography Versus Conventional-Dose Computed Tomography in the Evaluation of Distal Radius Fractures
    Zeng, Steven L.
    Grier, A. Jordan
    Langdell, Hannah C.
    Blevins, Kier M.
    Tian, William M.
    French, Robert J.
    Mithani, Suhail K.
    Hammert, Warren C.
    Klifto, Christopher S.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024,
  • [23] Development and validation of a fully automated system using deep learning for opportunistic osteoporosis screening using low-dose computed tomography scans
    Niu, Xinyi
    Huang, Yilin
    Li, Xinyu
    Yan, Wenming
    Lu, Xuanyu
    Jia, Xiaoqian
    Li, Jianying
    Hu, Jieliang
    Sun, Tianze
    Jing, Wenfeng
    Guo, Jianxin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 5294 - +
  • [24] Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis
    Diekhoff, Torsten
    Hermann, Kay Geert A.
    Lambert, Robert G.
    CURRENT RHEUMATOLOGY REPORTS, 2022, 24 (06) : 198 - 205
  • [25] Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis
    Torsten Diekhoff
    Kay Geert A. Hermann
    Robert G. Lambert
    Current Rheumatology Reports, 2022, 24 : 198 - 205
  • [26] RADIATION DOSE DURING LUNG CANCER SCREENING WITH LOW-DOSE COMPUTED TOMOGRAPHY: HOW LOW IS LOW DOSE?
    Marshall, H.
    Smith, I.
    Keir, B. J.
    Bowman, R. V.
    Crossin, J.
    Fuentes, M.
    Slaughter, R.
    Passmore, L.
    McCaul, E.
    Courtenay, D.
    Webb, M.
    Windsor, M.
    Yang, I. A.
    Zimmerman, P. V.
    Hayes, R.
    Redmond, S.
    Fong, K. M.
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (03) : S36 - S36
  • [27] Low-Dose Computed Tomography for Lung Cancer Screening: The Protocol and The Dose
    McDermott, Shaunagh
    Kaira, Mannudeep K.
    SEMINARS IN ROENTGENOLOGY, 2017, 52 (03) : 132 - 136
  • [28] Image Fusion for Low-Dose Computed Tomography Reconstruction
    Ma, Jianhua
    Huang, Jing
    Liang, Zhengrong
    Zhang, Hua
    Fan, Yi
    Feng, Qianjin
    Chen, Wufan
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4239 - 4243
  • [29] Screening for lung cancer with low-dose computed tomography
    Diederich, S
    Wormanns, D
    Heindel, W
    RADIOLOGE, 2001, 41 (03): : 256 - 260
  • [30] UTILITY OF LOW DOSE COMPUTED TOMOGRAPHY IN OBESE PATIENTS WITH UROLITHIASIS
    Amasyali, Akin S.
    Belle, Joshua D.
    Martin, Gabriel E.
    Smith, Jason
    Farkouh, Ala'a
    Baldwin, D. Duane
    JOURNAL OF UROLOGY, 2024, 211 (05): : E308 - E309