Ventilation-induced plethysmographic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients

被引:60
|
作者
Wyffels, Piet A. H.
Durnez, Pieter-Jan
Helderweirt, Johan
Stockman, Willem M. A.
De Kegel, Dirk
机构
[1] UZ Gasthuisberg, Dept Anaesthesiol, B-3000 Louvain, Belgium
[2] Heiling Hart Ziekenhuis Roeselare, Dept Anaesthesiol & Crit Care, Roeselare, Belgium
来源
ANESTHESIA AND ANALGESIA | 2007年 / 105卷 / 02期
关键词
D O I
10.1213/01.ane.0000267520.16003.17
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: It has been shown that ventilation-induced pulse pressure variation (PPV) is a better variable than central venous pressure (CVP) or pulmonary artery occlusion pressure (PAOP) for predicting cardiac output changes after fluid administration. The plethysmographic wave form measured with a fingertip pulse is very similar to the arterial blood pressure curve. Methods: We investigated whether this widely used, noninvasive instrument could predict fluid responsiveness by conducting an observational study in 32 patients who had undergone cardiac surgery. We compared PPV, CVP, PAOP, diastolic pulmonary artery pressure, and ventilation-induced plethysmographic variation (VPV) for predicting the cardiac output change after the administration of 500 ml, 6% hydroxyethylstarch. Results: We found a good correlation between cardiac output changes and both PPV and VPV (P < 0.05). Receiver operating characteristic analysis revealed an area under the curve of 0.937 for PPV and 0.892 for VPV. The optimal thresholds were a variation of 11.3% for both PPV and VPV in predicting a 15% increase in cardiac output. Conclusion: This study shows that VPV, like PPV, is a more reliable predictor of fluid responsiveness than CVP and PAOP.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [41] Comment on "Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients" by Feissel et al. - Reply to the comment by Drs. Cannesson et al.
    Feissel, Marc
    Teboul, Jean Louis
    Bendjelid, Karim
    INTENSIVE CARE MEDICINE, 2007, 33 (10) : 1854 - 1854
  • [42] Internal jugular vein collapsibility does not predict fluid responsiveness in spontaneously breathing patients after cardiac surgery
    Horejsek, Jan
    Balik, Martin
    Kunstyr, Jan
    Michalek, Pavel
    Kopecky, Petr
    Brozek, Tomas
    Bartosova, Tereza
    Fink, Adam
    Waldauf, Petr
    Porizka, Michal
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (06) : 1563 - 1571
  • [43] Passive leg raising test induced changes in plethysmographic variability index to assess fluid responsiveness in critically ill mechanically ventilated patients with acute circulatory failure
    Mallat, Jihad
    Lemyze, Malcolm
    Fischer, Marc-Olivier
    JOURNAL OF CRITICAL CARE, 2024, 79
  • [44] Internal jugular vein collapsibility does not predict fluid responsiveness in spontaneously breathing patients after cardiac surgery
    Jan Horejsek
    Martin Balík
    Jan Kunstýř
    Pavel Michálek
    Petr Kopecký
    Tomáš Brožek
    Tereza Bartošová
    Adam Fink
    Petr Waldauf
    Michal Porizka
    Journal of Clinical Monitoring and Computing, 2023, 37 : 1563 - 1571
  • [45] Predicting and monitoring fluid responsiveness in patients after cardiac surgery by assessment of left ventricular stroke volume variations
    Reuter, DA
    Felbinger, TW
    Schmidt, C
    Kilger, E
    Goetz, AE
    INTENSIVE CARE MEDICINE, 2001, 27 : S287 - S287
  • [46] Using extra systoles and the micro-fluid challenge to predict fluid responsiveness during cardiac surgery
    Vistisen, Simon T.
    Berg, Jonas M.
    Boekel, Mattheus F.
    Modestini, Marco
    Bergman, Remco
    Jainandunsing, Jayant S.
    Mariani, Massimo A.
    Scheeren, Thomas W. L.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (05) : 777 - 786
  • [47] Using extra systoles and the micro-fluid challenge to predict fluid responsiveness during cardiac surgery
    Simon T. Vistisen
    Jonas M. Berg
    Mattheus F. Boekel
    Marco Modestini
    Remco Bergman
    Jayant S. Jainandunsing
    Massimo A. Mariani
    Thomas W. L. Scheeren
    Journal of Clinical Monitoring and Computing, 2019, 33 : 777 - 786
  • [48] Ability of Carotid Corrected Flow Time to Predict Fluid Responsiveness in Patients Mechanically Ventilated Using Low Tidal Volume after Surgery
    Jung, Seungho
    Kim, Jeongmin
    Na, Sungwon
    Nam, Won Seok
    Kim, Do-Hyeong
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (12)
  • [49] Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery
    Zimmermann, Markus
    Feibicke, Thomas
    Keyl, Cornelius
    Prasser, Christopher
    Moritz, Stefan
    Graf, Bernhard M.
    Wiesenack, Christoph
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (06) : 555 - 561
  • [50] Postoperative pneumonia following cardiac surgery in non-ventilated patients versus mechanically ventilated patients: is there any difference?
    Allou, Nicolas
    Allyn, Jerome
    Snauwaert, Aurelie
    Welsch, Camille
    Lucet, Jean Christophe
    Kortbaoui, Rita
    Desmard, Mathieu
    Augustin, Pascal
    Montravers, Philippe
    CRITICAL CARE, 2015, 19