Ventilation-induced plethysmographic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients

被引:60
|
作者
Wyffels, Piet A. H.
Durnez, Pieter-Jan
Helderweirt, Johan
Stockman, Willem M. A.
De Kegel, Dirk
机构
[1] UZ Gasthuisberg, Dept Anaesthesiol, B-3000 Louvain, Belgium
[2] Heiling Hart Ziekenhuis Roeselare, Dept Anaesthesiol & Crit Care, Roeselare, Belgium
来源
ANESTHESIA AND ANALGESIA | 2007年 / 105卷 / 02期
关键词
D O I
10.1213/01.ane.0000267520.16003.17
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: It has been shown that ventilation-induced pulse pressure variation (PPV) is a better variable than central venous pressure (CVP) or pulmonary artery occlusion pressure (PAOP) for predicting cardiac output changes after fluid administration. The plethysmographic wave form measured with a fingertip pulse is very similar to the arterial blood pressure curve. Methods: We investigated whether this widely used, noninvasive instrument could predict fluid responsiveness by conducting an observational study in 32 patients who had undergone cardiac surgery. We compared PPV, CVP, PAOP, diastolic pulmonary artery pressure, and ventilation-induced plethysmographic variation (VPV) for predicting the cardiac output change after the administration of 500 ml, 6% hydroxyethylstarch. Results: We found a good correlation between cardiac output changes and both PPV and VPV (P < 0.05). Receiver operating characteristic analysis revealed an area under the curve of 0.937 for PPV and 0.892 for VPV. The optimal thresholds were a variation of 11.3% for both PPV and VPV in predicting a 15% increase in cardiac output. Conclusion: This study shows that VPV, like PPV, is a more reliable predictor of fluid responsiveness than CVP and PAOP.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 50 条
  • [31] Carotid doppler indices do not predict fluid responsiveness in mechanically ventilated patients undergoing coronary artery bypass grafting surgery
    Khan, Saba
    Mishra, Sandeep Kumar
    Parida, Satyen
    Jha, Ajay Kumar
    Padala, Sri Rama Ananta Nagabhushanam
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 4418 - 4424
  • [32] Ventilator-induced central venous pressure variation can predict fluid responsiveness in post-operative cardiac surgery patients
    Cherpanath, T. G. V.
    Geerts, B. F.
    Maas, J. J.
    de Wilde, R. B. P.
    Groeneveld, A. B.
    Jansen, J. R.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2016, 60 (10) : 1395 - 1403
  • [33] Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre
    Cannesson, M.
    Desebbe, O.
    Rosamel, P.
    Delannoy, B.
    Robin, J.
    Bastien, O.
    Lehot, J. -J.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (02) : 200 - 206
  • [34] Stroke volume changes induced by a recruitment maneuver predict fluid responsiveness in patients with protective ventilation in the operating theater
    De Broca, Bruno
    Garnier, Jeremie
    Fischer, Marc-Olivier
    Archange, Thomas
    Marc, Julien
    Abou-Arab, Osama
    Dupont, Herve
    Lorne, Emmanuel
    Guinot, Pierre-gregoire
    MEDICINE, 2016, 95 (28)
  • [35] Prediction of fluid responsiveness by FloTrac™ and PiCCOplus™ in cardiac surgery patients
    C Hofer
    A Senn
    A Zollinger
    Critical Care, 12 (Suppl 2):
  • [36] PREDICTING FLUID RESPONSIVENESS IN POST-CARDIAC SURGERY PATIENTS
    Meijs, Loek
    Bindels, Alexander
    Roos, Arnout
    Lima, Alexandre
    Bakker, Jan
    CRITICAL CARE MEDICINE, 2015, 43 (12)
  • [37] Passive leg raising induced-changes in blood pressure predict fluid responsiveness following cardiac surgery
    Fischer, M. -O
    Lemetayer, C.
    Gerard, J. -L
    Hanouz, J. -L
    Fellahi, J. -L
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 59 - 59
  • [38] Plethysmographic variation index predicts fluid responsiveness in ventilated patients in the early phase of septic shock in the emergency department: A pilot study
    Feissel, Marc
    Kalakhy, Rachid
    Banwarth, Pierre
    Badie, Julio
    Pavon, Arnaud
    Faller, Jean-Pierre
    Quenot, Jean-Pierre
    JOURNAL OF CRITICAL CARE, 2013, 28 (05) : 634 - 639
  • [39] Proving the effectiveness of three dynamic indices to predict fluid responsiveness in septic mechanically ventilated patients
    P Wacharasint
    A Lertamornpong
    A Wathanathum
    A Wongsa
    Critical Care, 13 (Suppl 1):
  • [40] Ability of a New Smartphone Pulse Pressure Variation and Cardiac Output Application to Predict Fluid Responsiveness in Patients Undergoing Cardiac Surgery
    Joosten, Alexandre
    Boudart, Celine
    Vincent, Jean-Louis
    Eynden, Frederic Vanden
    Barvais, Luc
    Van Obbergh, Luc
    Rinehart, Joseph
    Desebbe, Olivier
    ANESTHESIA AND ANALGESIA, 2019, 128 (06): : 1145 - 1151