Passive leg raising test induced changes in plethysmographic variability index to assess fluid responsiveness in critically ill mechanically ventilated patients with acute circulatory failure

被引:1
|
作者
Mallat, Jihad [1 ,2 ,3 ,4 ]
Lemyze, Malcolm [1 ]
Fischer, Marc-Olivier [5 ]
机构
[1] Arras Hosp, Dept Crit Care Med, Arras, France
[2] Cleveland Clin Abu Dhabi, Crit Care Inst, POB 112412, Abu Dhabi, U Arab Emirates
[3] Case Western Reserve Univ, Lerner Coll Med, Cleveland Clin, Cleveland, OH USA
[4] Normandy Univ, UNICAEN, ED 497, Caen, France
[5] Inst Aquitain Coeur, Clin St Augustin, ELSAN, 114 Ave Ares, F-33074 Bordeaux, France
关键词
Cardiac output; Fluid challenge; Fluid responsiveness; Passive leg raising test; Pulse pressure variation; Plethysmographic variability index; Perfusion index; Pulse oximetry; Acute circulatory failure; Sepsis; Gray zone; Mechanical ventilation; PULSE PRESSURE VARIATION; WAVE-FORM AMPLITUDE; RESPIRATORY VARIATIONS; SEPTIC SHOCK; PREDICT; PERFUSION; ACCURACY; OXIMETRY; ABILITY; SEPSIS;
D O I
10.1016/j.jcrc.2023.154449
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Passive leg raising (PLR) reliably predicts fluid responsiveness but requires a real-time cardiac index (CI) measurement or the presence of an invasive arterial line to achieve this effect. The plethysmographic variability index (PVI), an automatic measurement of the respiratory variation of the perfusion index, is non-invasive and continuously displayed on the pulse oximeter device. We tested whether PLR-induced changes in PVI (Delta PVIPLR) could accurately predict fluid responsiveness in mechanically ventilated patients with acute circulatory failure.Methods: This was a secondary analysis of an observational prospective study. We included 29 mechanically ventilated patients with acute circulatory failure in this study. We measured PVI (Radical-7 device; Masimo Corp., Irvine, CA) and CI (Echocardiography) before and during a PLR test and before and after volume expansion of 500 mL of crystalloid solution. A volume expansion-induced increase in CI of >15% defined fluid responsiveness. To investigate whether Delta PVIPLR can predict fluid responsiveness, we determined areas under the receiver operating characteristic curves (AUROCs) and gray zones for Delta PVIPLR.Results: Of the 29 patients, 27 (93.1%) received norepinephrine. The median tidal volume was 7.0 [IQR: 6.6-7.6] mL/kg ideal body weight. Nineteen patients (65.5%) were classified as fluid responders (increase in CI > 15% after volume expansion). Relative Delta PVIPLR accurately predicted fluid responsiveness with an AUROC of 0.89 (95%CI: 0.72-0.98, p < 0.001). A decrease in PVI <= -24.1% induced by PLR detected fluid responsiveness with a sensitivity of 95% (95%CI: 74-100%) and a specificity of 80% (95%CI: 44-97%). Gray zone was acceptable, including 13.8% of patients. The correlations between the relative Delta PVIPLR and changes in CI induced by PLR and by volume expansion were significant (r = -0.58, p < 0.001, and r = -0.65, p < 0.001; respectively).Conclusions: In sedated and mechanically ventilated ICU patients with acute circulatory failure, PLR-induced changes in PVI accurately predict fluid responsiveness with an acceptable gray zone.
引用
收藏
页数:8
相关论文
共 33 条
  • [1] Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients
    A Lafanechère
    F Pène
    C Goulenok
    A Delahaye
    V Mallet
    G Choukroun
    JD Chiche
    JP Mira
    A Cariou
    Critical Care, 10
  • [2] Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients
    Lafanechere, A.
    Pene, F.
    Goulenok, C.
    Delahaye, A.
    Mallet, V.
    Choukroun, G.
    Chiche, J. D.
    Mira, J. P.
    Cariou, A.
    CRITICAL CARE, 2006, 10 (05):
  • [3] Passive leg raising-induced changes in pulse pressure variation to assess fluid responsiveness in mechanically ventilated patients: a multicentre prospective observational study
    Mallat, Jihad
    Fischer, Marc-Olivier
    Granier, Maxime
    Vinsonneau, Christophe
    Jonard, Marie
    Mahjoub, Yazine
    Baghdadi, Fawzi Ali
    Preau, Sebastien
    Poher, Fabien
    Rebet, Olivier
    Bouhemad, Belaid
    Lemyze, Malcolm
    Marzouk, Mehdi
    Besnier, Emmanuel
    Hamed, Fadi
    Rahman, Nadeem
    Abou-Arab, Osama
    Guinot, Pierre-Gregoire
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (03) : 308 - 316
  • [4] The Passive Leg Raising Test To Guide Fluid Removal in Critically Ill Patients
    X Monnet
    F Cipriani
    L Camous
    P Sentenac
    M Dres
    E Krastinova
    N Anguel
    C Richard
    JL Teboul
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [5] The passive leg raising test to guide fluid removal in critically ill patients
    Monnet, Xavier
    Cipriani, Flora
    Camous, Laurent
    Sentenac, Pierre
    Dres, Martin
    Krastinova, Evguenia
    Anguel, Nadia
    Richard, Christian
    Teboul, Jean-Louis
    ANNALS OF INTENSIVE CARE, 2016, 6
  • [6] The passive leg raising test to guide fluid removal in critically ill patients
    Xavier Monnet
    Flora Cipriani
    Laurent Camous
    Pierre Sentenac
    Martin Dres
    Evguenia Krastinova
    Nadia Anguel
    Christian Richard
    Jean-Louis Teboul
    Annals of Intensive Care, 6
  • [7] Assessment of the plethysmographic variability index as a predictor of fluid responsiveness in critically ill patients: a pilot study
    Baker, A. K.
    Partridge, R. J. O.
    Litton, E.
    Ho, K. M.
    ANAESTHESIA AND INTENSIVE CARE, 2013, 41 (06) : 736 - 741
  • [8] Changes in the Cardiac Index Induced by Unilateral Passive Leg Raising in Spontaneously Breathing Patients: A Novel Way to Assess Fluid Responsiveness
    Zhao, Zhiyong
    Zhang, Zhongwei
    Lin, Qionghua
    Shen, Lihua
    Wang, Pengmei
    Zhang, Shan
    Xia, Zhili
    Li, Fangfang
    Xing, Qian
    Zhu, Biao
    FRONTIERS IN MEDICINE, 2022, 9
  • [9] Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients
    Boulain, T
    Achard, JM
    Teboul, JL
    Richard, C
    Perrotin, D
    Ginies, G
    CHEST, 2002, 121 (04) : 1245 - 1252
  • [10] Can Passive Leg Raising (PLR) Test Induced End-Tidal Carbon Dioxide (ETCO2) Changes Predict Fluid Responsiveness in Mechanically Ventilated Patients?
    Taggu, Alai
    CHEST, 2015, 148 (04)