Comparison of Reactive Gaseous Mercury Collection by Different Sampling Methods in a Laboratory Test and Field Monitoring

被引:21
|
作者
Bu, Xiaoge [1 ]
Zhang, Hefeng [1 ]
Lv, Guangkuo [1 ]
Lin, Huiming [2 ]
Chen, Long [3 ]
Yin, Xiufeng [4 ]
Shen, Guofeng [2 ]
Yuan, Wen [2 ]
Zhang, Wei [5 ]
Wang, Xuejun [2 ]
Tong, Yindong [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Peking Univ, Coll Urban & Environm Sci, Beijing 100871, Peoples R China
[3] East China Normal Univ, Sch Geog Sci, Shanghai 200241, Peoples R China
[4] Chinese Acad Sci, Northwest Inst Ecoenvironm & Resources, State Key Lab Cryospher Sci, Lanzhou 730000, Gansu, Peoples R China
[5] Renmin Univ China, Sch Environm & Nat Resources, Beijing 100872, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
SPECIATED ATMOSPHERIC MERCURY; CATION-EXCHANGE MEMBRANES; KCL-COATED DENUDERS; AMBIENT AIR; PHOTOLYTIC REDUCTION; MINAMATA CONVENTION; ELEMENTAL MERCURY; WET DEPOSITION; AEROSOLS; CHINA;
D O I
10.1021/acs.estlett.8b00439
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurately measuring reactive gaseous mercury (RGM) concentrations in the atmosphere is important to improve our understanding of the global mercury (Hg) cycle. In this study, we compared the RGM collection efficiencies of four sampling methods, including a 14 cm long KCl-coated denuder, a KCl-coated glass fiber filter, a KCl-coated quartz sand tube, and a cation exchange membrane. Both laboratory studies and field RGM monito ring were performed in environments with low humidity [relative humidity (RH) of similar to 20%], medium humidity (RH of S0-70%), and high humidity (RH of similar to 100%). Laboratory results showed that in environments with <70% RH, RGM amounts collected by the KCl-coated glass fiber filter and the KCl-coated quartz sand tube were comparable with those collected with the cation exchange membrane. In environments with similar to 100% RH, the cation exchange membrane collected more RGM, approximately 1.1-1.4, 1.1-1.2, and 2.4-2.7 times more than the KCl-coated glass fiber filter, KCl-coated quartz sand tube, and KCl-coated denuder, respectively. During field monitoring, RGM amounts collected with the KCl-coated quartz sand tube were comparable to those collected with the cation exchange membrane regardless of the RH in the environment (p > 0.05; n = 60). Large variations (<= 20 during field monitoring) in RGM concentrations measured by different sampling methods indicate the need for a unified and standardized method for future RGM monitoring.
引用
收藏
页码:600 / 607
页数:15
相关论文
共 50 条
  • [21] Laboratory comparison of measurement procedures for workplace monitoring of mercury vapor
    Dragan, George C.
    Hebisch, Ralph
    Woznica, Anita
    Warzecha, Andrea
    Martiny, Anastasia
    Hassemer, Rüdiger
    Nitschke, Lutz
    Nehls, Ralf
    Fendler, Dirk
    Gefahrstoffe Reinhaltung der Luft, 2021, 81 (9-10): : 339 - 344
  • [22] Laboratory comparison of measurement procedures for workplace monitoring of mercury vapor
    Dragan, G. C.
    Hebisch, R.
    Woznica, A.
    Warzecha, A.
    Martiny, A.
    Hassemer, R.
    Nitschke, L.
    Nehls, R.
    Fendler, D.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2021, 81 (9-10): : 339 - 344
  • [23] Use of Mercury Dry Deposition Samplers to Quantify Dry Deposition of Particulate-Bound Mercury and Reactive Gaseous Mercury at a Traffic Sampling Site
    Fang, Guor-Cheng
    Lin, Yen-Heng
    Chang, Chia-Ying
    ENVIRONMENTAL FORENSICS, 2013, 14 (03) : 182 - 186
  • [24] COMPARISON OF FIELD METHODS IN VEGETATION MONITORING
    BRAKENHIELM, S
    LIU, QH
    WATER AIR AND SOIL POLLUTION, 1995, 79 (1-4): : 75 - 87
  • [25] Field comparison of manual and semi-automatic methods for the measurement of total gaseous mercury in ambient air and assessment of equivalence
    Brown, Richard J. C.
    Kumar, Yarshini
    Brown, Andrew S.
    Dexter, Matthew A.
    Corns, Warren T.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (02): : 657 - 665
  • [26] COMPARISON OF PH MEASUREMENT BY FIELD AND LABORATORY METHODS
    STEINHARDT, GC
    MENGEL, DB
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1981, 12 (01) : 71 - 78
  • [27] Comparison of different laboratory methods in the diagnosis of onychomycosis
    Dubljanin, E. S.
    Calovski, I. V. Colovic
    Dzamic, A. M.
    Mitrovic, M.
    Arsenijevic, V. S. Arsic
    MYCOSES, 2013, 56 : 76 - 76
  • [28] Laboratory and field testing of sampling methods for inhalable and respirable dust
    Linnainmaa, Markku
    Laitinen, Juha
    Leskinen, Ari
    Sippula, Olli
    Kalliokoski, Pentti
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (01) : 28 - 35
  • [29] SAMPLING FOR FORMALDEHYDE IN WORKPLACE AND AMBIENT AIR ENVIRONMENTS - ADDITIONAL LABORATORY AND FIELD VERIFICATION OF A PASSIVE AIR MONITORING BADGE WITH CONVENTIONAL SAMPLING METHODS
    KRING, EV
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 186 (AUG): : 21 - CHAS
  • [30] A COMPARISON OF 4 PERSONAL SAMPLING METHODS FOR THE DETERMINATION OF MERCURY-VAPOR
    MCCAMMON, CS
    EDWARDS, SL
    HULL, RD
    WOODFIN, WJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (07): : 528 - 531