Comparison of Reactive Gaseous Mercury Collection by Different Sampling Methods in a Laboratory Test and Field Monitoring

被引:21
|
作者
Bu, Xiaoge [1 ]
Zhang, Hefeng [1 ]
Lv, Guangkuo [1 ]
Lin, Huiming [2 ]
Chen, Long [3 ]
Yin, Xiufeng [4 ]
Shen, Guofeng [2 ]
Yuan, Wen [2 ]
Zhang, Wei [5 ]
Wang, Xuejun [2 ]
Tong, Yindong [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Peking Univ, Coll Urban & Environm Sci, Beijing 100871, Peoples R China
[3] East China Normal Univ, Sch Geog Sci, Shanghai 200241, Peoples R China
[4] Chinese Acad Sci, Northwest Inst Ecoenvironm & Resources, State Key Lab Cryospher Sci, Lanzhou 730000, Gansu, Peoples R China
[5] Renmin Univ China, Sch Environm & Nat Resources, Beijing 100872, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
SPECIATED ATMOSPHERIC MERCURY; CATION-EXCHANGE MEMBRANES; KCL-COATED DENUDERS; AMBIENT AIR; PHOTOLYTIC REDUCTION; MINAMATA CONVENTION; ELEMENTAL MERCURY; WET DEPOSITION; AEROSOLS; CHINA;
D O I
10.1021/acs.estlett.8b00439
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurately measuring reactive gaseous mercury (RGM) concentrations in the atmosphere is important to improve our understanding of the global mercury (Hg) cycle. In this study, we compared the RGM collection efficiencies of four sampling methods, including a 14 cm long KCl-coated denuder, a KCl-coated glass fiber filter, a KCl-coated quartz sand tube, and a cation exchange membrane. Both laboratory studies and field RGM monito ring were performed in environments with low humidity [relative humidity (RH) of similar to 20%], medium humidity (RH of S0-70%), and high humidity (RH of similar to 100%). Laboratory results showed that in environments with <70% RH, RGM amounts collected by the KCl-coated glass fiber filter and the KCl-coated quartz sand tube were comparable with those collected with the cation exchange membrane. In environments with similar to 100% RH, the cation exchange membrane collected more RGM, approximately 1.1-1.4, 1.1-1.2, and 2.4-2.7 times more than the KCl-coated glass fiber filter, KCl-coated quartz sand tube, and KCl-coated denuder, respectively. During field monitoring, RGM amounts collected with the KCl-coated quartz sand tube were comparable to those collected with the cation exchange membrane regardless of the RH in the environment (p > 0.05; n = 60). Large variations (<= 20 during field monitoring) in RGM concentrations measured by different sampling methods indicate the need for a unified and standardized method for future RGM monitoring.
引用
收藏
页码:600 / 607
页数:15
相关论文
共 50 条
  • [31] A pilot study of different materials applied for active sampling of gaseous oxidized mercury in the atmospheric air
    Urba, A.
    Valiulis, D.
    Sarlauskas, J.
    Kvietkus, K.
    Sakalys, J.
    Selskis, A.
    ATMOSPHERIC POLLUTION RESEARCH, 2017, 8 (04) : 791 - 799
  • [32] Comparison of Different Item Scoring Methods and Different Test Scoring Methods
    Yurdugul, Halil
    JOURNAL OF MEASUREMENT AND EVALUATION IN EDUCATION AND PSYCHOLOGY-EPOD, 2010, 1 (01): : 1 - 8
  • [33] Gaseous Elemental Mercury Concentrations along the Northern Gulf of Mexico Using Passive Air Sampling, with a Comparison to Active Sampling
    Jeon, Byunggwon
    Cizdziel, James V.
    Brewer, J. Stephen
    Luke, Winston T.
    Cohen, Mark D.
    Ren, Xinrong
    Kelley, Paul
    ATMOSPHERE, 2020, 11 (10)
  • [34] The efficiency of different sampling methods for the collection of prescription frequencies in group practices
    Grohmann, H
    JAHRBUCHER FUR NATIONALOKONOMIE UND STATISTIK, 1998, 217 (01): : 36 - 48
  • [35] FLAMMABILITY OF DRAPERY TYPE FABRICS - 2-LABORATORY COMPARISON OF 2 DIFFERENT TEST METHODS
    HICKIE, TS
    HOSCHKE, BN
    WILLIAMS, D
    JOURNAL OF CONSUMER PRODUCT FLAMMABILITY, 1979, 6 (03): : 211 - 217
  • [36] A Comparison of PAH Emission Sampling Methods (Cyclone, Impactor) in Particulate and Gaseous Phase
    Horak, Jiri
    Kubonova, Lenka
    Krpec, Kamil
    Hopan, Frantisek
    Kubesa, Petr
    Kolonicny, Jan
    Placha, Daniela
    AEROSOL AND AIR QUALITY RESEARCH, 2018, 18 (04) : 849 - 855
  • [37] Monitoring of the Anticoagulants Argatroban and Lepirudin: A Comparison of Laboratory Methods
    Ivandic, Boris
    Zorn, Markus
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2011, 17 (05) : 549 - 555
  • [38] Comparison of collection efficiencies of sampling methods for removable beryllium surface contamination
    Dufay, SK
    Archuleta, M
    JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (06): : 630 - 633
  • [39] A SURVEY AND COMPARISON OF LABORATORY TEST METHODS FOR MEASURING WICKING
    HARNETT, PR
    MEHTA, PN
    TEXTILE RESEARCH JOURNAL, 1984, 54 (07) : 471 - 478
  • [40] NONUNIFORM SAMPLING OF URODYNAMIC SIGNALS - A COMPARISON OF DIFFERENT METHODS
    KOCJAN, T
    VANMASTRIGT, R
    UROLOGICAL RESEARCH, 1994, 22 (03): : 137 - 141