Differences in effective dose estimation from dose-area product and entrance surface dose measurements in intravenous urography

被引:48
|
作者
Yakoumakis, E
Tsalafoutas, IA
Nikolaou, D
Nazos, I
Koulentianos, E
Proukakis, C
机构
[1] Univ Athens, Sch Med, Dept Med Phys, GR-11527 Athens, Greece
[2] Konstantopoulio Agia Olga Hosp, Dept Radiol, Athens 14233, Greece
[3] Konstantopoulio Agia Olga Hosp, Med Phys Unit, Athens 14233, Greece
来源
BRITISH JOURNAL OF RADIOLOGY | 2001年 / 74卷 / 884期
关键词
D O I
10.1259/bjr.74.884.740727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, measurements of dose-area product (DAP) and entrance surface dose (ESD) were carried out in a sample of 25 adult patients who underwent intravenous urography (IVU). These measured quantities were used to estimate the effective dose E from the IVU examination, a quantity closely correlated to radiation risk. Estimating E involves the use of conversion coefficients that have been determined for specific X-ray views in a mathematical phantom. These are obtained under conditions which are not usually met in clinical practice. As a result, the E estimates using the two different measurable quantities can be quite different. Analysis of the calculation procedure suggests that the E estimate using the DAP measurements, in addition to being more practical, could be more accurate than using ESD measurements, as DAP is sensitive to the X-ray field size settings. Furthermore, it is shown that in the absence of the appropriate equipment, a reliable E estimate can be obtained from the ESD calculated using the exposure data for each X-ray view.
引用
收藏
页码:727 / 734
页数:8
相关论文
共 50 条
  • [21] ESTIMATION OF EFFECTIVE DOSE TO THE PATIENT DURING MEDICAL X-RAY EXAMINATIONS FROM MEASUREMENTS OF THE DOSE AREA PRODUCT
    LEHERON, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (11): : 2117 - 2126
  • [22] CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSES IN INTRAORAL AND PANORAMIC DENTAL RADIOLOGY FROM DOSE-AREA PRODUCT VALUES
    Looe, H. K.
    Eenboom, F.
    Chofor, N.
    Pfaffenberger, A.
    Steinhoff, M.
    Ruehmann, A.
    Poplawski, A.
    Willborn, K.
    Poppe, B.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (03) : 365 - 373
  • [23] Sensitivity of coefficients for converting entrance surface dose and kerma-area product to effective dose and energy imparted to the patient
    Wise, KN
    Sandborg, M
    Persliden, J
    Carlsson, GA
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08): : 1937 - 1954
  • [24] Skin dose and dose-area product values in patients undergoing intracoronary brachytherapy
    Vano, E
    Prieto, C
    Fernandez, JM
    Gonzalez, L
    Sabate, M
    Galvan, C
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (901): : 32 - 38
  • [25] Changes in Dose-Area Product, Entrance Surface Dose, and Lens Dose to the Radiologist in a Vascular Interventional Laboratory when an Old X-ray System Is Exchanged with a New System
    Jensen, Kristin
    Zangani, Livia
    Martinsen, Anne Catrine
    Sandbk, Gunnar
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 34 (04) : 717 - 722
  • [26] Dose indices in dental cone beam CT and correlation with dose-area product
    Araki, K.
    Patil, S.
    Endo, A.
    Okano, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [27] Changes in Dose-Area Product, Entrance Surface Dose, and Lens Dose to the Radiologist in a Vascular Interventional Laboratory when an Old X-ray System Is Exchanged with a New System
    Kristin Jensen
    Livia Zangani
    Anne Catrine Martinsen
    Gunnar Sandbæk
    CardioVascular and Interventional Radiology, 2011, 34 : 717 - 722
  • [28] Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures
    Hansson, B
    Karambatsakidou, A
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 141 - 144
  • [29] A new formula for converting dose-area product to effective dose in dental cone-beam computed tomography
    Pauwels, Ruben
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112
  • [30] Using a dose-area product for absolute measurements in small fields: a feasibility study
    Dufreneix, S.
    Ostrowsky, A.
    Le Roy, M.
    Sommier, L.
    Gouriou, J.
    Delaunay, F.
    Rapp, B.
    Daures, J.
    Bordy, J-M
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 650 - 662