CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSES IN INTRAORAL AND PANORAMIC DENTAL RADIOLOGY FROM DOSE-AREA PRODUCT VALUES

被引:21
|
作者
Looe, H. K. [1 ,2 ]
Eenboom, F. [1 ,2 ]
Chofor, N. [1 ,2 ]
Pfaffenberger, A. [1 ,2 ]
Steinhoff, M. [3 ]
Ruehmann, A. [2 ]
Poplawski, A. [2 ]
Willborn, K. [2 ]
Poppe, B. [1 ,2 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Med Radiat Phys Working Grp, D-26111 Oldenburg, Germany
[2] Pius Hosp, Clin Radiotherapy & Oncol, D-26121 Oldenburg, Germany
[3] Oko Inst eV, Darmstadt Off, Nucl Engn & Plant Safety Div, D-64295 Darmstadt, Germany
关键词
D O I
10.1093/rpd/ncn172
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose-area product (DAP) values were determined by measuring organ-absorbed doses and the corresponding DAP values. Measurements were performed for all standard intraoral radiological projections and standard panoramic examination at different exposure parameters. Organ-absorbed doses were measured using thermoluminescent detectors and an adult anthropomorphic phantom specially designed for dosimetric study in dental radiology. Different techniques for the calculation of effective doses were evaluated. Conversion coefficients derived from this study range from 0.008 to 0.132 mu Sv mGy(-1) cm(-2) for intraoral radiography and 0.055 to 0.238 mu Sv mGy(-1) cm(-2) for panoramic radiography.
引用
收藏
页码:365 / 373
页数:9
相关论文
共 32 条
  • [1] Dose-area product measurements and determination of conversion coefficients for the estimation of effective dose in dental lateral cephalometric radiology
    Looe, H. K.
    Eenboom, F.
    Chofor, N.
    Pfaffenberger, A.
    Sering, M.
    Ruehmann, A.
    Poplawski, A.
    Willborn, K.
    Poppe, B.
    RADIATION PROTECTION DOSIMETRY, 2007, 124 (02) : 181 - 186
  • [2] Dose-area product measurements in panoramic dental radiology
    Poppe, B.
    Looe, H. K.
    Pfaffenberger, A.
    Chofor, N.
    Eenboom, F.
    Sering, M.
    Ruehmann, A.
    Poplawski, A.
    Willborn, K.
    RADIATION PROTECTION DOSIMETRY, 2007, 123 (01) : 131 - 134
  • [3] A conversion coefficient from dose-area products to effective doses for patients in intraoral radiography
    Sato K.
    Sakaino R.
    Yosue T.
    Harata Y.
    Oral Radiology, 2002, 18 (1) : 15 - 24
  • [4] Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements
    Wade, JP
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (849): : 994 - 994
  • [5] Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology
    Bor, D
    Sancak, T
    Olgar, T
    Elcim, Y
    Adanali, A
    Sanlidilek, U
    Akyar, S
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916): : 315 - 322
  • [6] Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements - Reply
    Hart, D
    Jones, D
    Wall, B
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (849): : 995 - 995
  • [7] Method for the Estimation of Effective Doses for Dental Intraoral and Panoramic Radiography
    Shatskiy, I. G.
    6TH INTERNATIONAL CONFERENCE ON X-RAY, ELECTROVACUUM AND BIOMEDICAL TECHNIQUE, 2020, 2250
  • [8] Determination of dose-area product from panoramic radiography using a pencil ionization chamber: Normalized data for the estimation of patient effective and organ doses
    Perisinakis, K
    Damilakis, J
    Neratzoulakis, J
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2004, 31 (04) : 708 - 714
  • [9] Dose area product reference levels in dental panoramic radiology
    Tierris, CE
    Yakoumakis, EN
    Bramis, GN
    Georgiou, E
    RADIATION PROTECTION DOSIMETRY, 2004, 111 (03) : 283 - 287
  • [10] Dose-Area Product to Effective Dose Conversion Coefficients for Pelvic Radiography Using a Monte Carlo Program
    Chen, David S.
    Escobedo, Eva M.
    Eastman, Jonathan G.
    Bloomstein, Joshua D.
    Taylor, Sandra L.
    Seibert, J. Anthony
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (03) : 679 - 684