Method for the Estimation of Effective Doses for Dental Intraoral and Panoramic Radiography

被引:0
|
作者
Shatskiy, I. G. [1 ]
机构
[1] St Petersburg Res Inst Radiat Hyg, St Petersburg, Russia
关键词
REDUCTION;
D O I
10.1063/5.0013321
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The doses of patients for the most common intraoral and panoramic radiographic dental studies were evaluated and compared with the published data. The range of median values of effective doses for intraoral examinations on the units with films detectors was from 3.5 to 8.2 mu Sv and for the units with digital detectors the corresponding range was from 1.2 to 2.5 mu Sv. For panoramic examinations median value of the effective dose was 22.9 mu Sv. The ranges without emissions for the examination of premolars of the upper jaw, molars of both jaws and occlusion have the substantial width. Results compared with published data indicated that the effective doses in St. Petersburg and the regional institutions are lower than the values obtained using standard round collimator and medium and high sensitivity films (class D and F, respectively), as well as lower dose levels in the European Commission Guidelines. However, the effective doses in St. Petersburg and the Leningrad Region are higher than those obtained using a square collimator and high-sensitivity films. The present study suggests the possibility of further optimization. Obtained dose values can be used as reference for local regulations concerning patient dose in dental radiography and preliminary value prior to the establishment of national diagnostic reference level
引用
收藏
页数:6
相关论文
共 50 条
  • [1] ORGAN ABSORBED DOSES IN INTRAORAL DENTAL RADIOGRAPHY
    RAMSEY, LJ
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (799): : 744 - 744
  • [2] ORGAN ABSORBED DOSES IN INTRAORAL DENTAL RADIOGRAPHY
    LECOMBER, AR
    FAULKNER, K
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (791): : 1035 - 1041
  • [3] Radiation doses in extraoral bitewing radiography compared with intraoral bitewing and panoramic radiography
    Dorsey, Anne K.
    Mol, Andre
    Green, Peter
    Ludlow, John
    Johnson, Brandon
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2024, 137 (02): : 182 - 189
  • [4] INTRAORAL OR PANORAMIC RADIOGRAPHY
    BEAN, LR
    AKERMAN, WY
    DENTAL CLINICS OF NORTH AMERICA, 1984, 28 (01) : 47 - 55
  • [5] CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSES IN INTRAORAL AND PANORAMIC DENTAL RADIOLOGY FROM DOSE-AREA PRODUCT VALUES
    Looe, H. K.
    Eenboom, F.
    Chofor, N.
    Pfaffenberger, A.
    Steinhoff, M.
    Ruehmann, A.
    Poplawski, A.
    Willborn, K.
    Poppe, B.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (03) : 365 - 373
  • [6] DENTAL PANORAMIC RADIOGRAPHY WITH INTRAORAL X-RAY TUBES
    KEUR, JJ
    MACDONALD, R
    AUSTRALIAN DENTAL JOURNAL, 1986, 31 (01) : 40 - 43
  • [7] Optimisation of patient doses in programmable dental panoramic radiography
    Lecomber, AR
    Downes, SL
    Mokhtari, M
    Faulkner, K
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) : 107 - 112
  • [8] Digital Panoramic Radiography in Dental Age Estimation
    Kazemipoor, Maryam
    Motallaei, Mohammad Nima
    Dehghani, Mandieh
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2021, 11 (03): : 10585 - 10594
  • [9] Dosimetric study of the effective doses resulting during dental X-ray and panoramic radiography
    Shousha, Hany A.
    Abd-El Hafez, A. I.
    Ahmad, Fawzia
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2011, 166 (01): : 67 - 73
  • [10] Dynamic focal plane estimation for dental panoramic radiography
    Kim, Seungeon
    Ra, Jong Beom
    MEDICAL PHYSICS, 2019, 46 (11) : 4907 - 4917