Method for the Estimation of Effective Doses for Dental Intraoral and Panoramic Radiography

被引:0
|
作者
Shatskiy, I. G. [1 ]
机构
[1] St Petersburg Res Inst Radiat Hyg, St Petersburg, Russia
关键词
REDUCTION;
D O I
10.1063/5.0013321
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The doses of patients for the most common intraoral and panoramic radiographic dental studies were evaluated and compared with the published data. The range of median values of effective doses for intraoral examinations on the units with films detectors was from 3.5 to 8.2 mu Sv and for the units with digital detectors the corresponding range was from 1.2 to 2.5 mu Sv. For panoramic examinations median value of the effective dose was 22.9 mu Sv. The ranges without emissions for the examination of premolars of the upper jaw, molars of both jaws and occlusion have the substantial width. Results compared with published data indicated that the effective doses in St. Petersburg and the regional institutions are lower than the values obtained using standard round collimator and medium and high sensitivity films (class D and F, respectively), as well as lower dose levels in the European Commission Guidelines. However, the effective doses in St. Petersburg and the Leningrad Region are higher than those obtained using a square collimator and high-sensitivity films. The present study suggests the possibility of further optimization. Obtained dose values can be used as reference for local regulations concerning patient dose in dental radiography and preliminary value prior to the establishment of national diagnostic reference level
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Diagnostic reference levels at intraoral and dental panoramic examinations
    Hodolli, G.
    Kadiri, S.
    Nafezi, G.
    Bahtijari, M.
    Syla, N.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (01): : 147 - 150
  • [42] Aspects of panoramic radiography in general dental practice
    V E Rushton
    K Horner
    H V Worthington
    British Dental Journal, 1999, 186 (7) : 342 - 344
  • [43] Image quality assessment and radiation doses in intraoral radiography
    Yakoumakis, EN
    Tierris, CE
    Stefanou, EP
    Phanourakis, IG
    Proukakis, CC
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2001, 91 (03): : 362 - 368
  • [44] Paediatric absorbed doses from rotational panoramic radiography
    Hayakawa, Y
    Kobayashi, N
    Kuroyanagi, K
    Nishizawa, K
    DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (05) : 285 - 292
  • [45] REDUCTION OF ABSORBED BODY DOSES IN ROTATIONAL PANORAMIC RADIOGRAPHY
    AAGAARD, A
    SEWERIN, I
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 609 - 609
  • [46] COMPARISON OF INTERPROXIMAL CARIOUS LESION DETECTION IN PANORAMIC AND STANDARD INTRAORAL RADIOGRAPHY
    HURLBURT, CE
    WUEHRMANN, AH
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1976, 93 (06): : 1154 - 1158
  • [47] THE INTEGRAL DOSE IN PANORAMIC INTRAORAL X-RAY TUBE RADIOGRAPHY
    HAYAMI, A
    FUJISHITA, M
    SUMIDA, A
    KANKE, M
    FUJIKI, T
    UEMURA, S
    FUCHIHATA, H
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1983, 56 (01): : 98 - 102
  • [48] EFFECTIVE DOSES AND RADIATION RISKS FROM COMMON DENTAL RADIOGRAPHIC, PANORAMIC AND CBCT EXAMINATIONS
    Shatskiy, I
    RADIATION PROTECTION DOSIMETRY, 2021, 195 (3-4) : 296 - 305
  • [49] Estimation of organ and effective doses from newborn radiography of the chest and abdomen
    Ma, Hillgan
    Elbakri, Idris A.
    Reed, Martin
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (02) : 160 - 167
  • [50] EFFECTIVE DOSE EQUIVALENT FROM INTRAORAL RADIOGRAPHY
    STENSTROM, B
    HENRIKSON, CO
    KARLSSON, L
    SARBY, B
    SWEDISH DENTAL JOURNAL, 1987, 11 (1-2) : 71 - 77