CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSES IN INTRAORAL AND PANORAMIC DENTAL RADIOLOGY FROM DOSE-AREA PRODUCT VALUES

被引:21
|
作者
Looe, H. K. [1 ,2 ]
Eenboom, F. [1 ,2 ]
Chofor, N. [1 ,2 ]
Pfaffenberger, A. [1 ,2 ]
Steinhoff, M. [3 ]
Ruehmann, A. [2 ]
Poplawski, A. [2 ]
Willborn, K. [2 ]
Poppe, B. [1 ,2 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Med Radiat Phys Working Grp, D-26111 Oldenburg, Germany
[2] Pius Hosp, Clin Radiotherapy & Oncol, D-26121 Oldenburg, Germany
[3] Oko Inst eV, Darmstadt Off, Nucl Engn & Plant Safety Div, D-64295 Darmstadt, Germany
关键词
D O I
10.1093/rpd/ncn172
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose-area product (DAP) values were determined by measuring organ-absorbed doses and the corresponding DAP values. Measurements were performed for all standard intraoral radiological projections and standard panoramic examination at different exposure parameters. Organ-absorbed doses were measured using thermoluminescent detectors and an adult anthropomorphic phantom specially designed for dosimetric study in dental radiology. Different techniques for the calculation of effective doses were evaluated. Conversion coefficients derived from this study range from 0.008 to 0.132 mu Sv mGy(-1) cm(-2) for intraoral radiography and 0.055 to 0.238 mu Sv mGy(-1) cm(-2) for panoramic radiography.
引用
收藏
页码:365 / 373
页数:9
相关论文
共 32 条
  • [21] A PHANTOM BASED METHOD FOR DERIVING TYPICAL PATIENT DOSES FROM MEASUREMENTS OF DOSE-AREA PRODUCT ON POPULATIONS OF PATIENTS
    CHAPPLE, CL
    BROADHEAD, DA
    FAULKNER, K
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (814): : 1083 - 1086
  • [22] Converting dose-area product to effective dose in dental cone-beam computed tomography using organ-specific deep learning
    Pauwels, Ruben
    DENTOMAXILLOFACIAL RADIOLOGY, 2024,
  • [23] A new formula for converting dose-area product to effective dose in dental cone-beam computed tomography (vol 112,102639, 2023)
    Pauwels, Ruben
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
  • [24] Dose area product in estimation of effective dose of the patients undergoing dental cone beam computed tomography examinations
    Kralik, Ivana
    Faj, Dario
    Lauc, Tomislav
    Skarica, Matko
    Popic, Jelena
    Brkic, Hrvoje
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (04) : 1412 - 1427
  • [25] Use of secondary air kerma from dose area product and fluoroscopy time for preventive effective dose estimation in interventional radiology procedures for staff
    Indovina, Luca
    Moretti, Roberto
    Breschi, Laura
    Cusumano, Davide
    Meffe, Guenda
    Placidi, Lorenzo
    Nardini, Matteo
    Reale, Roberta
    Quici, Arturo
    Placidi, Elisa
    Stimato, Gerardina
    Capotosti, Amedeo
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (02)
  • [26] Review of air kerma-area product, effective dose and dose conversion coefficients for non-cardiac interventional fluoroscopy procedures
    Miller, Donald L.
    MEDICAL PHYSICS, 2020, 47 (03) : 975 - 982
  • [27] ESTIMATION OF EFFECTIVE DOSE TO THE PATIENT DURING MEDICAL X-RAY EXAMINATIONS FROM MEASUREMENTS OF THE DOSE AREA PRODUCT
    LEHERON, JC
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (11): : 2117 - 2126
  • [28] Conversion factors to estimate effective doses from kerma area product in interventional cardiology. Impact of added filtration
    Vano, Eliseo
    Sanchez, Roberto M.
    Fernandez, Jose M.
    Ten, Jose, I
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 104 - 111
  • [29] Review of kerma-area product, effective dose and dose conversion coefficients for non-cardiac interventional fluoroscopy procedures (vol 47, pg 975, 2020)
    Miller, Donald L.
    MEDICAL PHYSICS, 2020, 47 (11) : 5966 - 5967
  • [30] Conversion factors for effective dose and organ doses with the air kerma area product in patients undergoing percutaneous transhepatic biliary drainage and trans arterial chemoembolization
    Brambilla, M.
    Cannillo, B.
    Guzzardi, G.
    D'Alessio, Andrea
    Galbiati, Andrea
    Matheoud, Roberta
    Carriero, A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 72 : 7 - 15