Application of CR-39 for the characterization of the neutron distribution in the neutron radiography channel of the Algerian reactor NUR is reported. The neutron detection assembly, consisting of a boron neutron-charged particle converter in contact with CR-39, was used to map the neutron flux over a 10.5 x 21 cm(2) area. The relationship between the CR-39 track density and the neutron flux has been established by a mathematical development of the detection and revelation conditions for the charged particles emitted in the neutron-induced reactions in the converter. The degree of homogeneity of the neutron field has been determined and the higher and lower neutron fluxes have been situated. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [1] SEMIEMPIRICAL MODEL OF NEUTRON AND CHARGED-PARTICLE INTERACTION WITH CR-39
    PARKHURST, MA
    HADLOCK, DE
    FAUST, LG
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 593 - 596
  • [2] STUDIES OF CHARGED-PARTICLE TRACKS IN NTA FILMS AND CR-39 FOIL FOR NEUTRON MEASUREMENT
    KASIM, MM
    BEGUM, Z
    KHAN, AH
    FARUQUE, SB
    CHOWDHURY, MS
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (04): : 619 - 621
  • [3] COPOLYMERS OF CR-39 FOR NEUTRON DOSIMETRY
    YANG, CS
    HUANG, SJ
    JOHNSON, JF
    HADLOCK, DE
    PARKHURST, MA
    HEALTH PHYSICS, 1986, 50 : S19 - S19
  • [4] NEUTRON SENSITIVITY OF CR-39 SSNTD
    BIRKHOLZ, W
    WINKLER, C
    BAUMBACH, H
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 453 - 456
  • [5] Optimization of CR-39 as neutron dosimeter
    Kumar, Vijay
    Sonkawade, R. G.
    Dhaliwal, A. S.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2010, 48 (07) : 466 - 469
  • [6] NEUTRON RESPONSE CHARACTERISTICS OF CR-39 POLYMER FOR REACTOR AND DOSIMETRY APPLICATIONS
    RUDDY, FH
    GOLD, R
    ROBERTS, JH
    PRESTON, CC
    BENTON, EV
    SCHRAUBE, H
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 372 - 372
  • [7] METHOD FOR NEUTRON DETECTION EFFICIENCY MEASUREMENTS AND NEUTRON-CHARGED PARTICLE COINCIDENCE DETECTION
    JACKSON, WR
    DIVATIA, AS
    BONNER, BE
    JOSEPH, C
    EMERSON, ST
    CHEN, YS
    TAYLOR, MC
    SIMPSON, WD
    VALKOVIC, V
    PAUL, EB
    PHILLIPS, GC
    NUCLEAR INSTRUMENTS & METHODS, 1967, 55 (02): : 349 - &
  • [8] A CR-39 FAST-NEUTRON DOSIMETER BASED ON AN (N,ALPHA) CONVERTER
    SAVVIDIS, E
    SAMPSONIDIS, D
    ZAMANI, M
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 341 - 342
  • [9] NEUTRON-CHARGED PARTICLE COINCIDENCE MEASUREMENTS FROM 14.4 MEV NEUTRON INDUCED REACTIONS
    VALKOVIC, V
    MILJANIC, D
    TOMAS, P
    ANTOLKOVIC, B
    FURIC, M
    NUCLEAR INSTRUMENTS & METHODS, 1969, 76 (01): : 29 - +
  • [10] Response of a CR-39 fast neutron dosemeter with a polyethylene converter improved with Makrofol
    Fernandez, F
    Bouassoule, T
    Domingo, C
    Luguera, E
    Baixeras, C
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 343 - 347