Neutron distribution in a reactor exit channel by neutron-charged particle converter and CR-39

被引:7
|
作者
Seghour, A. [1 ]
Seghour, F. Z. [1 ]
Saichi, B. [2 ]
机构
[1] Commiss Energie Atom, Ctr Rech Nucl Alger, Algiers 16000, Algeria
[2] Commiss Energie Atom, Ctr Rech Nucl Draria, Algiers 16003, Algeria
关键词
neutron detection; neutron distribution; boron converter; CR-39;
D O I
10.1016/j.nima.2008.02.041
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Application of CR-39 for the characterization of the neutron distribution in the neutron radiography channel of the Algerian reactor NUR is reported. The neutron detection assembly, consisting of a boron neutron-charged particle converter in contact with CR-39, was used to map the neutron flux over a 10.5 x 21 cm(2) area. The relationship between the CR-39 track density and the neutron flux has been established by a mathematical development of the detection and revelation conditions for the charged particles emitted in the neutron-induced reactions in the converter. The degree of homogeneity of the neutron field has been determined and the higher and lower neutron fluxes have been situated. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [31] NEUTRON DOSIMETRY STUDIES USING CR-39 PLASTIC
    HARRISON, KG
    PERKS, CA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 374 - 374
  • [32] The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC)
    Bolzonella, Matteo
    Caresana, Marco
    Gilvin, Philip J.
    Yukihara, Eduardo G.
    Chevallier, Marie-Anne
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1867 - 1871
  • [33] Application of CR-39™ SSNTD with a boron converter for the characterization of the external neutron beam of a powder diffractometer
    L. Boukerdja
    A. Seghour
    O. Dendene
    A. Ali
    H. Slamene
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 1159 - 1165
  • [34] Application of CR-39™ SSNTD with a boron converter for the characterization of the external neutron beam of a powder diffractometer
    Boukerdja, L.
    Seghour, A.
    Dendene, O.
    Ali, A.
    Slamene, H.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (03) : 1159 - 1165
  • [35] Determination of CR-39 detection efficiency for fast neutron registration and the absolute neutron dosimetry
    El-Sersy, AR
    Khaled, NE
    Eman, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 215 (3-4): : 443 - 448
  • [36] REVIEW OF EVIDENCE FOR IRRADIATION DAMAGE FROM NEUTRON-CHARGED PARTICLE REACTIONS IN METALS
    BLOOM, EE
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (02): : 701 - &
  • [37] CR-39 detector based thermal neutron flux measurements, in the photo neutron project
    Mameli, A.
    Greco, F.
    Fidanzio, A.
    Fusco, V.
    Cilla, S.
    D'Onofrio, G.
    Grimaldi, L.
    Augelli, B. G.
    Giannini, G.
    Bevilacqua, R.
    Totaro, P.
    Tommasino, L.
    Azario, L.
    Piermattei, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (16): : 3656 - 3660
  • [38] Charged particle identification using CR-39(DOP) detector
    Yadav, J.S.
    Radiation Measurements, 1995, 24 (02):
  • [39] Fast neutron dosimetry with CR-39 using electrochemical etching
    Fernandez, F.
    Domingo, C.
    Baixeras, C.
    Luguera, E.
    Zamani, M.
    Debeauvais, M.
    Nuclear Tracks and Radiation Measurements, 1991, 19 (1-4): : 467 - 470
  • [40] A NEUTRON DOSIMETRY SYSTEM BASED ON THE CHEMICAL ETCH OF CR-39
    HARVEY, JR
    WEEKS, AR
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 629 - 632