摘要
Application of CR-39 for the characterization of the neutron distribution in the neutron radiography channel of the Algerian reactor NUR is reported. The neutron detection assembly, consisting of a boron neutron-charged particle converter in contact with CR-39, was used to map the neutron flux over a 10.5 x 21 cm(2) area. The relationship between the CR-39 track density and the neutron flux has been established by a mathematical development of the detection and revelation conditions for the charged particles emitted in the neutron-induced reactions in the converter. The degree of homogeneity of the neutron field has been determined and the higher and lower neutron fluxes have been situated. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [21] TRIALS AND TRIBULATIONS OF PROCESSING CR-39 FOR NEUTRON DOSIMETRY
    PARKHURST, MA
    HAGGARD, DL
    TOMERAASEN, PL
    HADLOCK, DE
    HEALTH PHYSICS, 1984, 47 (01): : 155 - 155
  • [22] THE DEVELOPMENT OF NEUTRON DOSIMETER USING CR-39 DETECTOR
    ELKHATIB, AM
    ABOUELKHIER, AA
    FAWZY, MA
    ELCHENNAWI, SE
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1994, 128 (04): : 319 - 325
  • [23] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E
    Fantuzzi, E
    Giacomelli, G
    Giorgini, M
    Morelli, B
    Patrizii, L
    Serra, P
    Togo, V
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 437 - 442
  • [24] Neutron dosimetry at low and high fluences with CR-39
    Meyer, P
    Groetz, JE
    Fromm, M
    Lacourt, A
    Chambaudet, A
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 423 - 428
  • [25] CR-39 PLASTIC AS A NEUTRON DOSIMETER FOR PERSONNEL MONITORING
    OSWALD, RA
    WHEELER, RV
    BENTON, EV
    HEALTH PHYSICS, 1979, 37 (06): : 844 - 844
  • [26] IMPROVEMENT ON CR-39 MANUFACTURING FOR NEUTRON DOSIMETRY APPLICATIONS
    LEMBO, L
    CIVOLANI, O
    PATRIZII, L
    LODI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 633 - 636
  • [27] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E.
    Fantuzzi, E.
    Giacomelli, G.
    Giorgini, M.
    Morelli, B.
    Patrizii, L.
    Serra, P.
    Togo, V.
    Radiation Measurements, 1999, 31 (01): : 437 - 442
  • [28] A CR-39 track image analyser for neutron spectrometry
    D'Errico, F
    Weiss, M
    Luszik-Bhadra, M
    Matzke, M
    Bernardi, L
    Cecchi, A
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 823 - 830
  • [29] Computer simulation of the processes in a CR-39 neutron detector
    Lengar, I
    Skvarc, J
    Ilic, R
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 115 - 118
  • [30] NEW ETCHING CONDITIONS FOR CR-39 FOR NEUTRON DOSIMETRY
    AZIMIGARAKANI, D
    BOSCHUNG, M
    WERNLI, C
    RADIATION PROTECTION DOSIMETRY, 1991, 35 (02) : 93 - 98