Response of a CR-39 fast neutron dosemeter with a polyethylene converter improved with Makrofol

被引:9
|
作者
Fernandez, F
Bouassoule, T
Domingo, C
Luguera, E
Baixeras, C
机构
[1] Grup de Fis. de les Radiacions, Departament de Física, Univ. Autònoma de Barcelona
关键词
D O I
10.1093/oxfordjournals.rpd.a031750
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A personal fast neutron dosemeter is being developed using CR-39 as detector and several hydrogenated materials as proton converters. Configurations with polyethylene plates of different thicknesses placed before the CR-39 detector had been used to date. In the present work a Makrofol plate (300 mu m thick) was placed between the polyethylene (3 mm thick) converter and the CR-39 (500 mu m thick) detector, to a flatter energy response to neutrons arriving at various incidence angles. Dosemeters having this configuration have been exposed to monoenergetic neutron beams with energies ranging from 144 keV to 15.1 MeV, as well as to neutrons coming from a Cf-252 source, and for incidence angles between 0 degrees (normal incidence) and 85 degrees, at several known dose equivalent values. The CR-39 was electrochemically etched. Recorded tracks were counted using a semi-automatic system, based on an image analyser. The directional dose equivalent response in terms of H'(10,alpha) was evaluated from the net measured track densities. This response was also simulated using a Monte Carlo method taking into account the dosemeter configuration and etching conditions. Simulation of the response to normally incident neutrons allows a fit of the parameters related to the CR-39 proton registration efficiency. Excellent agreement was found between results estimated from the Monte Carlo method and experimental ones. The calibration factor obtained for estimating the directional dose equivalent with this dosemeter is 5.6 x 10(-3) mSv.cm(2) and the lower detection limit is 60 +/- 20 mu Sv.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 50 条
  • [1] Further investigations on CR-39 fast neutron personal dosemeter
    Djeffal, S
    Lounis, Z
    Allab, M
    Izerrouken, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 398 (2-3): : 343 - 350
  • [2] Further investigations on CR-39 fast neutron personal dosemeter
    Djeffal, S.
    Lounis, Z.
    Allab, M.
    Izerrouken, M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 398 (2-3): : 343 - 350
  • [3] Progress towards the development of a CR-39 fast neutron personal dosemeter
    Djeffal, S.
    Lounis, Z.
    Nuclear Tracks and Radiation Measurements, 1991, 19 (1-4): : 457 - 460
  • [4] Practical fast-neutron dosemeter based on electrochemically etched CR-39 detector with angle-independent response
    Matiullah
    Durrani, S.A.
    Khan, G.A.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1988, B34 (04) : 499 - 504
  • [5] A CR-39 FAST-NEUTRON DOSIMETER BASED ON AN (N,ALPHA) CONVERTER
    SAVVIDIS, E
    SAMPSONIDIS, D
    ZAMANI, M
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 341 - 342
  • [6] Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator
    Castillo, F.
    Espinosa, G.
    Golzarri, J. I.
    Osorio, D.
    Rangel, J.
    Reyes, P. G.
    Herrera, J. J. E.
    RADIATION MEASUREMENTS, 2013, 50 : 71 - 73
  • [7] Feasibility study of extremity dosemeter based on polyallyldiglycolcarbonate (CR-39) for neutron exposure
    Chau, Q.
    Bruguier, P.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 528 - 531
  • [8] EXPERIMENTAL AND THEORETICAL DETERMINATION OF THE FAST-NEUTRON RESPONSE USING CR-39 PLASTIC DETECTORS AND POLYETHYLENE RADIATORS
    FERNANDEZ, F
    DOMINGO, C
    LUGUERA, E
    BAIXERAS, C
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 337 - 340
  • [9] Effect of γ rays on fast neutron registration in CR-39
    Kobzev, AP
    El-Asser, MR
    El-Halem, AA
    Abdul-Ghaphar, US
    Salama, TA
    RADIATION MEASUREMENTS, 2003, 37 (03) : 201 - 204
  • [10] Optimization of CR-39 for fast neutron dosimetry applications
    Vilela, E
    Fantuzzi, E
    Giacomelli, G
    Giorgini, M
    Morelli, B
    Patrizii, L
    Serra, P
    Togo, V
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 437 - 442