A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer

被引:195
|
作者
Lattanzi, J [1 ]
McNeeley, S [1 ]
Pinover, W [1 ]
Horwitz, E [1 ]
Das, I [1 ]
Schultheiss, TE [1 ]
Hanks, GE [1 ]
机构
[1] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
关键词
prostate cancer; organ motion; computed tomography; ultrasound; radiation therapy;
D O I
10.1016/S0360-3016(98)00496-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Daily CT localization has been demonstrated to be a precise method of correcting radiation field placement by reducing setup and organ motion variations to facilitate dose escalation in prostate carcinoma. The purpose of this study was to evaluate the feasibility and accuracy of daily ultrasound-guided localization utilizing daily CT as a standard. The relatively simple computer-assisted ultrasound-based system is designed to be an efficient means of achieving daily accuracy. Methods and Materials: After five weeks of conformal external beam radiation therapy, 23 patients underwent a second CT simulation. Prostate-only fields based on this scan were created with no PTV margin. On each of the final conedown treatment days, a repeat CT simulation and isocenter comparison was performed. Ten of the above patients also underwent prostate localization with a newly developed ultrasound-based system (BAT(TM)) that is designed to facilitate patient positioning at the treatment machine. The portable system, which electronically imports the CT simulation target contours and isocenter, is situated adjacent to the treatment couch. Transverse and sagittal suprapubic ultrasound images are captured, and the system overlays the corresponding CT contours relative to the machine isocenter. The CT contours are maneuvered in three dimensions by a touch screen menu to match the ultrasound images. The system then displays the 3-D couch shifts required to produce field alignment. Results: The BAT(TM) ultrasound system produced good quality images with minimal operator training required. The localization process was completed in less than 5 min. The absolute magnitude difference between CT and ultrasound was small (AIP range 0 to 5.9 mm, mean 3 mm +/- 1.8; Lat. range 0 to 7.9 mm, mean 2.4 mm +/- 1.8; S/I range 0 to 9 mm, mean 4.6 mm +/- 2.8). Analysis confirmed a significant correlation of isocenter shifts (A/P 0.66,p < 0.0001; Lat. r = 0.58,p < 0.003; S/I r = 0.78,p < 0.0001) in all dimensions, and linear regression confirmed the equivalence of the two modalities. Conclusions: Daily CT localization is a precise method to improve daily target localization in prostate carcinoma. However, it requires significant human and technical resources that limit its widespread applicability. Conversely, localization with the BAT(TM) ultrasound system is simple and expeditious by virtue of its ability to image the prostate at the treatment machine in the treatment position. Our initial evaluation revealed ultrasound targeting to be functionally equivalent to CT. This ultrasound technology is promising and warrants further investigation in more patients and at other anatomical sites. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:719 / 725
页数:7
相关论文
共 50 条
  • [1] Experience of ultrasound-based daily prostate localization
    Chandra, A
    Dong, L
    Huang, E
    Kuban, DA
    O'Neill, L
    Rosen, I
    Pollack, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02): : 436 - 447
  • [2] Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer
    Morr, J
    DiPetrillo, T
    Tsai, JS
    Engler, M
    Wazer, DE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1124 - 1129
  • [3] Daily ultrasound-based prostate localization: can we reduce the margins for prostate motion?
    Vandeputte, V
    Hermans, J
    Bussels, B
    Depuydt, T
    Oyen, R
    Suetens, P
    Haustermans, K
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S181 - S182
  • [4] Comparison between CT-based and ultrasound-based localization for prostate patients
    Paskalev, K.
    Feigenberg, S.
    McNeeley, S.
    Horwitz, E.
    Price, R.
    Wang, L.
    Konski, A.
    Ma, C.
    Pollack, A.
    MEDICAL PHYSICS, 2006, 33 (06) : 2028 - 2028
  • [5] Impact of the observers' experience on daily prostate localization accuracy in ultrasound-based IGRT with the Clarity platform
    Fiandra, Christian
    Guarneri, Alessia
    Munoz, Fernando
    Moretto, Francesco
    Filippi, Andrea Riccardo
    Levis, Mario
    Ragona, Riccardo
    Ricardi, Umberto
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 168 - 173
  • [6] Comparison between CT-based and ultrasound-based daily target localization for post-prostatectomy patients treated with IMRT
    Paskalev, K
    Feigenberg, S
    Jacob, R
    McNeeley, S
    Horwitz, E
    Ma, C
    Pollack, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1870 - 1870
  • [7] Ultrasound-based image guided radiotherapy for prostate cancer - Comparison of cross-modality and intramodality methods for daily localization during external beam radiotherapy
    Cury, Fabio L. B.
    Shenouda, George
    Souhami, Luis
    Duclos, Marie
    Faria, Sergio L.
    David, Marc
    Verhaegen, Frank
    Corns, Robert
    Falco, Tony
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (05): : 1562 - 1567
  • [8] A Comparison of daily megavoltage CT and ultrasound image guided radiation therapy for prostate cancer
    Peng, Cheng
    Kainz, Kristofer
    Lawton, Colleen
    Li, X. Allen
    MEDICAL PHYSICS, 2008, 35 (12) : 5619 - 5628
  • [9] A comparison of daily megavoltage CT and ultrasound imaging guided radiation therapy for prostate cancer
    Peng, C.
    Kainz, K.
    Lawton, C.
    Li, X.
    MEDICAL PHYSICS, 2007, 34 (06) : 2378 - 2378
  • [10] Intensity modulated radiation therapy with ultrasound-based daily target localization for clinically localized prostate cancer: institutional experience and acute toxicity outcomes
    Melcon, I. Rodriguez
    Martin, C.
    Soria, P.
    Marques, E.
    Oviedo, A.
    Martin, M.
    EJC SUPPLEMENTS, 2007, 5 (04): : 297 - 297