A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer

被引:195
|
作者
Lattanzi, J [1 ]
McNeeley, S [1 ]
Pinover, W [1 ]
Horwitz, E [1 ]
Das, I [1 ]
Schultheiss, TE [1 ]
Hanks, GE [1 ]
机构
[1] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 04期
关键词
prostate cancer; organ motion; computed tomography; ultrasound; radiation therapy;
D O I
10.1016/S0360-3016(98)00496-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Daily CT localization has been demonstrated to be a precise method of correcting radiation field placement by reducing setup and organ motion variations to facilitate dose escalation in prostate carcinoma. The purpose of this study was to evaluate the feasibility and accuracy of daily ultrasound-guided localization utilizing daily CT as a standard. The relatively simple computer-assisted ultrasound-based system is designed to be an efficient means of achieving daily accuracy. Methods and Materials: After five weeks of conformal external beam radiation therapy, 23 patients underwent a second CT simulation. Prostate-only fields based on this scan were created with no PTV margin. On each of the final conedown treatment days, a repeat CT simulation and isocenter comparison was performed. Ten of the above patients also underwent prostate localization with a newly developed ultrasound-based system (BAT(TM)) that is designed to facilitate patient positioning at the treatment machine. The portable system, which electronically imports the CT simulation target contours and isocenter, is situated adjacent to the treatment couch. Transverse and sagittal suprapubic ultrasound images are captured, and the system overlays the corresponding CT contours relative to the machine isocenter. The CT contours are maneuvered in three dimensions by a touch screen menu to match the ultrasound images. The system then displays the 3-D couch shifts required to produce field alignment. Results: The BAT(TM) ultrasound system produced good quality images with minimal operator training required. The localization process was completed in less than 5 min. The absolute magnitude difference between CT and ultrasound was small (AIP range 0 to 5.9 mm, mean 3 mm +/- 1.8; Lat. range 0 to 7.9 mm, mean 2.4 mm +/- 1.8; S/I range 0 to 9 mm, mean 4.6 mm +/- 2.8). Analysis confirmed a significant correlation of isocenter shifts (A/P 0.66,p < 0.0001; Lat. r = 0.58,p < 0.003; S/I r = 0.78,p < 0.0001) in all dimensions, and linear regression confirmed the equivalence of the two modalities. Conclusions: Daily CT localization is a precise method to improve daily target localization in prostate carcinoma. However, it requires significant human and technical resources that limit its widespread applicability. Conversely, localization with the BAT(TM) ultrasound system is simple and expeditious by virtue of its ability to image the prostate at the treatment machine in the treatment position. Our initial evaluation revealed ultrasound targeting to be functionally equivalent to CT. This ultrasound technology is promising and warrants further investigation in more patients and at other anatomical sites. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:719 / 725
页数:7
相关论文
共 50 条
  • [21] A comparison of CT- and ultrasound-based imaging to localize the prostate for external beam radiotherapy
    McNair, HA
    Mangar, SA
    Coffey, J
    Shoulders, B
    Hansen, VN
    Norman, A
    Staffurth, J
    Sohaib, SA
    Warrington, AP
    Dearnaley, DP
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03): : 678 - 687
  • [22] Daily prostate radiotherapy localization
    Dong, L
    Jaffray, D
    Van den Heuvel, F
    MEDICAL PHYSICS, 2004, 31 (06) : 1769 - 1769
  • [23] First clinical evaluation of 4D ultrasound system for daily prostate IGRT: Comparison with cone beam CT
    Zahno, M.
    Matzinger, O.
    Mazouni, Z.
    Cosinschi, A.
    Pachoud, M.
    Ghandour, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (06) : 604 - 604
  • [24] Dosimetric comparison of daily prostate alignment utilizing skin marks, ultrasound, and in-room CT
    O'Daniel, JC
    Dong, L
    Bonnen, M
    de Crevoisier, R
    Wang, H
    Cheung, R
    Lee, A
    Mohan, R
    Kuban, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S617 - S618
  • [25] Transition Form CT-Based to Ultrasound-Based HDR Treatment Planning for Prostate Cancer
    Veltchev, I.
    Price, R.
    Horwitz, E.
    Ma, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3469 - 3469
  • [26] Daily bone alignment with limited repeat CT correction rivals daily ultrasound alignment for prostate radiotherapy
    O'Daniel, J. C.
    Dong, L.
    Kudchadker, R. J.
    Kuban, D. A.
    de Crevoisier, R.
    Lee, A. K.
    Cheung, R.
    Zhang, L.
    Tucker, S. L.
    Mohan, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S639 - S640
  • [27] Daily bone alignment with limited repeat CT correction rivals daily ultrasound alignment for prostate radiotherapy
    O'Dantel, Jennifer C.
    Dong, Lei
    Zhang, Lifei
    Wang, He
    Tucker, Susan L.
    Kudchadker, Rajat J.
    Lee, Andrew K.
    Cheung, Rex
    Cox, James D.
    Kuban, Deborah A.
    Mohan, Radhe
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : 274 - 280
  • [28] Ultrasound Based Deformable Image Registration: Daily CT Images Derived From Daily IGRT Ultrasound
    van der Meer, S.
    Bouvy, D.
    Reniers, B.
    Fontanarosa, D.
    Verhaegen, F.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [29] Developments in Ultrasound-Based Imaging for Prostate Cancer Detection
    Vassallo, Reid
    Mannas, Miles P.
    Salcudean, Septimiu E.
    Black, Peter C.
    PROSTATE, 2025,
  • [30] Implementation of a Daily Transperineal Ultrasound System as Image-guided Radiotherapy for Prostate Cancer
    Hilman, S.
    Smith, R.
    Masson, S.
    Coomber, H.
    Bahl, A.
    Challapalli, A.
    Jacobs, P.
    CLINICAL ONCOLOGY, 2017, 29 (01) : E49 - E49