Reduced Field-of-View Diffusion Imaging of the Human Spinal Cord: Comparison with Conventional Single-Shot Echo-Planar Imaging

被引:87
|
作者
Zaharchuk, G. [1 ]
Saritas, E. U. [2 ]
Andre, J. B.
Chin, C. T. [3 ]
Rosenberg, J.
Brosnan, T. J.
Shankaranarayan, A. [4 ]
Nishimura, D. G. [2 ]
Fischbein, N. J.
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA USA
[4] GE Healthcare, Appl Sci Lab W, Menlo Pk, CA USA
关键词
WEIGHTED MRI; MULTIPLE-SCLEROSIS; IN-VIVO; CERVICAL CORD; OPTIC-NERVE; TENSOR MRI; RESOLUTION; INFARCTION; EPI; TRACTOGRAPHY;
D O I
10.3174/ajnr.A2418
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fF0V SS-EPI in a clinical population. MATERIALS AND METHODS: Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fF0V SS-EPI DWI normalized for either image readout time (low-resolution fF0V) or spatial resolution (high-resolution fF0V). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity-to-noise ratio, anatomic detail, and clinical utility. RESULTS: ADC values for the rFOV and both fF0V sequences were not statistically different (rFOV: 1.01 +/- 0.18 x 10(-3) mm(2)/s; low-resolution fFOV: 1.12 +/- 0.22 X 10(-3) mm(2)/s; high-resolution fFOV: 1.10 +/- 0.21 x 10(-3) mm(2)/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS: rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fF0V SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fF0V methods.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [21] Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging
    Yao, Feifei
    Huang, Mengyue
    Li, Juan
    Gao, Xuemei
    ABDOMINAL RADIOLOGY, 2023, 48 (06) : 2131 - 2138
  • [22] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Hong, Ben-Zu
    Li, Xin-Feng
    Lin, Jian-Qing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (20) : 6374 - 6380
  • [23] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Ben-Zu Hong
    Xin-Feng Li
    Jian-Qing Lin
    World Journal of Gastroenterology, 2015, (20) : 6374 - 6380
  • [24] Diffusion Tensor Imaging of the Normal Pediatric Spinal Cord Using an Inner Field of View Echo-Planar Imaging Sequence
    Barakat, N.
    Mohamed, F. B.
    Hunter, L. N.
    Shah, P.
    Faro, S. H.
    Samdani, A. F.
    Finsterbusch, J.
    Betz, R.
    Gaughan, J.
    Mulcahey, M. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1127 - 1133
  • [25] Readout-segmented echo-planar imaging in the evaluation of sinonasal lesions: A comprehensive comparison of image quality in single-shot echo-planar imaging
    Zhao, Menglong
    Liu, Zhuang
    Sha, Yan
    Wang, Shenjiang
    Ye, Xinpei
    Pan, Yucheng
    Wang, Shaoyu
    MAGNETIC RESONANCE IMAGING, 2016, 34 (02) : 166 - 172
  • [26] Single-shot echo-planar imaging with Nyquist ghost compensation: Interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI)
    Poser, Benedikt A.
    Barth, Markus
    Goa, Pal-Erik
    Deng, Weiran
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 37 - 47
  • [27] Comparison of Readout-Segmented and Conventional Single-Shot for Echo-Planar Diffusion-Weighted Imaging in the Assessment of Kidney Interstitial Fibrosis
    Friedli, Iris
    Crowe, Lindsey Alexandra
    de Perrot, Thomas
    Berchtold, Lena
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1631 - 1640
  • [28] Quantitative Susceptibility Mapping Using Single-Shot Echo-Planar Imaging
    Sun, Hongfu
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1932 - 1938
  • [29] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [30] Nonmuscle-invasive and Muscle-invasive Urinary Bladder Cancer Image Quality and Clinical Value of Reduced Field-of-view Versus Conventional Single-shot Echo-planar Imaging DWI
    Wang, Yanchun
    Li, Zhen
    Meng, Xiaoyan
    Hu, Xuemei
    Shen, Yaqi
    Morelli, John
    Lin, Hui
    Zhang, Zhongping
    Hu, Daoyu
    MEDICINE, 2016, 95 (10)