Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging

被引:0
|
作者
Yao, Feifei [1 ]
Huang, Mengyue [1 ]
Li, Juan [1 ]
Gao, Xuemei [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept MRI, Zhengzhou 450052, Peoples R China
关键词
Diffusion weighted imaging; Testis; Readout-segmented; TESTICULAR TORSION; COEFFICIENT VALUES;
D O I
10.1007/s00261-023-03899-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The current study aimed to explore the feasibility of readout-segmented echo-planar imaging (RS-EPI) of the testis at 3.0 T, by comparing with single-shot echo-planar imaging (SS-EPI) in qualitative image quality and quantitative apparent diffusion coefficient (ADC) values. Methods 66 patients undergoing scrotal MRI for various clinical indications were included retrospectively. RS-EPI image quality was rated from 1 (severe distortion or artifact, or nondiagnostic) to 4 (nearly no distortion or artifact, or outstanding). The comparative image quality (RS- vs. SS-EPI) was rated from - 2 (SS-EPI severe or greater conspicuity) to 2 (RS-EPI severe or greater conspicuity). The confidence interval of proportions (CIOP) of comparative image quality and Wilcoxon rank sum test were performed to assess the preferences between RS-EPI and SS-EPI. Paired samples t-test and Bland-Altman analysis were performed to compare the mean ADC values of RS-EPI and SS-EPI. The mean, maximum, and minimum ADC values measured by RS-EPI were compared in normal testicular parenchyma, benign and malignant intratesticular lesions. Results The evaluation of RS-EPI image quality showed RS-EPI with the characteristics of slight geometric distortion and susceptibility artifact, and good lesion conspicuity. The assessment of comparative image quality showed SS-EPI with obvious geometric distortion and susceptibility artifact, and RS-EPI preferred in lesion conspicuity. The CIOP ranged from 97 to 100% among three readers, with preferring to RS-EPI improving image quality (P < 0.001). There was a strong correlation and good agreement between mean ADC values measured by RS-EPI and SS-EPI. The mean, maximum and minimum ADC values by RS-EPI were significantly different in normal testicular parenchyma, benign and malignant intratesticular lesions. Conclusion RS-EPI DWI of the testis improved image quality in geometric distortion, susceptibility artifacts, and lesion conspicuity, and provided highly correlated and consistent mean ADC values when compared to SS-EPI DWI, indicating the feasibility of RS-EPI DWI of testes. [GRAPHICS] .
引用
收藏
页码:2131 / 2138
页数:8
相关论文
共 50 条
  • [1] Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging
    Feifei Yao
    Mengyue Huang
    Juan Li
    Xuemei Gao
    [J]. Abdominal Radiology, 2023, 48 : 2131 - 2138
  • [2] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    [J]. ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [3] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    [J]. Abdominal Radiology, 2016, 41 : 100 - 108
  • [4] Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality
    Kim, Yun Ju
    Kim, Sung Hun
    Kang, Bong Joo
    Park, Chang Suk
    Kim, Hyeon Sook
    Son, Yo Han
    Porter, David Andrew
    Song, Byung Joo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (04) : 403 - 410
  • [5] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [6] Diffusion Tensor Imaging of the Brachial Plexus: A Comparison between Readout-segmented and Conventional Single-shot Echo-planar Imaging
    Ho, Michael J.
    Ciritsis, Alexander
    Manoliu, Andrei
    Stieltjes, Bram
    Marcon, Magda
    Andreisek, Gustav
    Kuhn, Felix Pierre
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 150 - 157
  • [7] Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging
    Chen, Yueyao
    Pan, Zhongxian
    Meng, Fanqi
    Li, Zhujing
    Hu, Yuanming
    Yu, Xuewen
    Gao, Jinyun
    Guo, Yihao
    Lyu, Hanqing
    Lin, Xiaofeng
    [J]. FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [8] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [9] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    [J]. CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [10] Advanced diffusion weighted imaging of the prostate: Comparison of readout-segmented multi-shot, parallel-transmit and single-shot echo-planar imaging
    Klingebiel, M.
    Ullrich, T.
    Quentin, M.
    Bonekamp, D.
    Aissa, J.
    Mally, D.
    Arsov, C.
    Albers, P.
    Antoch, G.
    Schimmoeller, L.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130