Advanced diffusion weighted imaging of the prostate: Comparison of readout-segmented multi-shot, parallel-transmit and single-shot echo-planar imaging

被引:30
|
作者
Klingebiel, M. [1 ]
Ullrich, T. [1 ]
Quentin, M. [1 ]
Bonekamp, D. [3 ]
Aissa, J. [1 ]
Mally, D. [2 ]
Arsov, C. [2 ]
Albers, P. [2 ]
Antoch, G. [1 ]
Schimmoeller, L. [1 ]
机构
[1] Univ Dusseldorf, Fac Med, Dept Diagnost & Intervent Radiol, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Med Fac, Dept Urol, Moorenstr 5, D-40225 Dusseldorf, Germany
[3] German Canc Res Ctr, Div Radiol E010, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
关键词
Magnetic resonance imaging; Prostate cancer; Diffusion weighted MRI; Imaging; Diagnostic; HIGH B-VALUE; GEOMETRIC-DISTORTION; GLEASON SCORE; QUALITY; BIOPSY; MRI; LESIONS; RISK;
D O I
10.1016/j.ejrad.2020.109161
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study evaluates objective and subjective image quality (IQ) of three different diffusion weighted imaging (DWI) sequences in prostate MRI at 3.0 Tesla within the same patients. Method: Thirty-six consecutive patients (70 +/- 8 years) with multi-parametric prostate MRI (mp-MRI; 3 T) and subsequently verified prostate cancer (PCa) by targeted plus systematic MR/US-fusion biopsy from 03/2016 to 12/2017 were included. Readout-segmented (rs) multi shot echo-planar imaging (EPI), parallel transmit (ptx) EPI, and single-shot (ss) EPI with b-values of 0, (500,) 1,000 s/mm(2) and calculated b1,500 were prospectively acquired of every patient. Signal intensities (SI) of PCa and benign tissue (peripheral and transition zone; PZ and TZ) in ADC, b1,000, and calculated b1,500 images were analyzed. Endpoints were signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and subjective IQ on a 5-point scale by two blinded readers. Results: For ss-EPI ADC, b-values of 1,000, and calculated 1,500 s/mm(2) images showed a higher SNR compared to rs-EPI and ptx-EPI (p< 0.01). CNR of PCa and benign tissue was significantly higher for rs-EPI in high b value images compared to ptx-EPI and ss-EPI (p< 0.01). Subjective IQ was significantly higher for rs-EPI (p< 0.01). Significantly higher ADC reduction combined with signal increase on high b value images for PCa compared to the surrounding healthy tissue in PZ and TZ (PCa contrast intensity) was detected for rs-EPI (p< 0.01). Single PCa lesions could only be recognized and correlated on rs-EPI. Conclusions: Rs-EPI and ptx-EPI were superior to ss-EPI regarding contrast intensity of PCA, but inferior regarding SNR. Subjective imaging parameters were superior for rs-EPI. Especially rs-EPI, but also ptx-EPI might improve and faciliate prostate cancer detection, rs-EPI at the expense of a longer acquisition time.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging
    Feifei Yao
    Mengyue Huang
    Juan Li
    Xuemei Gao
    [J]. Abdominal Radiology, 2023, 48 : 2131 - 2138
  • [2] Readout-segmented diffusion weighted imaging of the testis at 3.0 T: comparison with single-shot echo-planar imaging
    Yao, Feifei
    Huang, Mengyue
    Li, Juan
    Gao, Xuemei
    [J]. ABDOMINAL RADIOLOGY, 2023, 48 (06) : 2131 - 2138
  • [3] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    [J]. ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [4] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    [J]. Abdominal Radiology, 2016, 41 : 100 - 108
  • [5] Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality
    Kim, Yun Ju
    Kim, Sung Hun
    Kang, Bong Joo
    Park, Chang Suk
    Kim, Hyeon Sook
    Son, Yo Han
    Porter, David Andrew
    Song, Byung Joo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (04) : 403 - 410
  • [6] Diffusion Tensor Imaging of the Brachial Plexus: A Comparison between Readout-segmented and Conventional Single-shot Echo-planar Imaging
    Ho, Michael J.
    Ciritsis, Alexander
    Manoliu, Andrei
    Stieltjes, Bram
    Marcon, Magda
    Andreisek, Gustav
    Kuhn, Felix Pierre
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 150 - 157
  • [7] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [8] Comparison of Readout-Segmented Echo-Planar Imaging and Single-Shot TSE DWI for Cholesteatoma Diagnostics
    Wiesmueller, M.
    Wuest, W.
    May, M. S.
    Ellmann, S.
    Heiss, R.
    Saake, M.
    Janka, R.
    Uder, M.
    Laun, F. B.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (07) : 1305 - 1312
  • [9] Performance of Single-Shot Echo-Planar Imaging in Diffusion Tensor Imaging in Rat Sciatic Nerve Compared With Readout-Segmented Echo-Planar Imaging
    Chen, Yueyao
    Pan, Zhongxian
    Meng, Fanqi
    Li, Zhujing
    Hu, Yuanming
    Yu, Xuewen
    Gao, Jinyun
    Guo, Yihao
    Lyu, Hanqing
    Lin, Xiaofeng
    [J]. FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [10] Comparison of Readout-Segmented and Conventional Single-Shot for Echo-Planar Diffusion-Weighted Imaging in the Assessment of Kidney Interstitial Fibrosis
    Friedli, Iris
    Crowe, Lindsey Alexandra
    de Perrot, Thomas
    Berchtold, Lena
    Martin, Pierre-Yves
    de Seigneux, Sophie
    Vallee, Jean-Paul
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1631 - 1640