Evaluation of volumetric blood collection devices for the measurement of phenylalanine and tyrosine to monitor patients with phenylketonuria

被引:16
|
作者
Carling, Rachel S. [1 ,2 ,5 ]
Emmett, Erin C. [2 ]
Moat, Stuart J. [3 ,4 ]
机构
[1] Kings Coll London, GKT Sch Med Educ, London, England
[2] Guys & St Thomas NHSFT, Biochem Sci, London, England
[3] Univ Hosp Wales, Dept Med Biochem Immunol & Toxicol, Cardiff, Wales
[4] Cardiff Univ, Univ Hosp Wales, Sch Med, Cardiff, Wales
[5] St Thomas Hosp, Biochem Sci, 4th Floor,North Wing,Westminster Bridge Rd, London SE1, England
关键词
Blood collection devices; Dried blood spots; DBS; Phenylalanine; Phenylketonuria; PKU; Microsampling; Tyrosine; Standardization; AMINO-ACIDS; HEMATOCRIT; PUNCH;
D O I
10.1016/j.cca.2022.08.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Measurement of dried blood spot (DBS) phenylalanine (Phe) is central to the monitoring of patients with phenylketonuria. However, the volume and hematocrit (Hct) of the blood applied to conventional DBS cards significantly affects analytical results. Volumetric blood collection devices are reported to be more accurate, precise and less prone to Hct effects.Methods: Accuracy, imprecision, effect of blood volume and Hct were evaluated for measurement of Phe and tyrosine using three volumetric devices and compared with the conventional PerkinElmer-226 filter-paper collection devices. i.e. conventional DBS cards. Applicability for use in a clinical laboratory was assessed qualitatively.Results: Blood volume did not impact on the performance of the volumetric devices; however, significant biases were observed with the conventional DBS card. A higher Hct introduced unacceptable bias for Neoteryx-Mitra and conventional DBS card. All devices had a mean relative standard deviation (RSD) <= 4.1 %, except for the Neoteryx-Mitra (<= 6.2 %). Relative to liquid blood, the mean biases of Phe for the various devices were-5.1 (HemaXis-DB10),-7.8 (Capitainer-qDBS),-12.0 (Neoteryx-Mitra) and-32.6 % (conventional DBS card).Conclusions: Introducing volumetric collection devices will overcome the significant pre-analytical issues asso-ciated with conventional DBS collection and improve the biochemical monitoring of patients with PKU.
引用
下载
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [21] Blood phenylalanine monitoring for dietary compliance among patients with phenylketonuria: comparison of methods
    Gregory, Cria O.
    Yu, Chunh
    Singh, Rani H.
    GENETICS IN MEDICINE, 2007, 9 (11) : 761 - 765
  • [22] Performance of laboratory tests used to measure blood phenylalanine for the monitoring of patients with phenylketonuria
    Moat, Stuart J.
    Schulenburg-Brand, Danja
    Lemonde, Hugh
    Bonham, James R.
    Weykamp, Cas W.
    Mei, Joanne V.
    Shortland, Graham S.
    Carling, Rachel S.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2020, 43 (02) : 179 - 188
  • [24] Evaluation of an automated blood collection monitor for weighing accuracy.
    Kline, L
    George, V
    Friedman, LT
    TRANSFUSION, 1996, 36 (09) : A3 - A3
  • [25] Neuropsychological speed tests and blood phenylalanine levels in patients with phenylketonuria: A meta-analysis
    Albrecht, Julia
    Garbade, Sven F.
    Burgard, Peter
    NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2009, 33 (03): : 414 - 421
  • [26] Self-assessed and objective blood phenylalanine levels in patients with early treated phenylketonuria
    Weglage, Josef
    Moeller, Harald E.
    Feldmann, Reinhold
    ACTA PAEDIATRICA, 2010, 99 (06) : 944 - 945
  • [27] RAPID DIAGNOSIS OF PHENYLKETONURIA BY QUANTITATIVE-ANALYSIS FOR PHENYLALANINE AND TYROSINE IN NEONATAL BLOOD SPOTS BY TANDEM MASS-SPECTROMETRY
    CHACE, DH
    MILLINGTON, DS
    TERADA, N
    KAHLER, SG
    ROE, CR
    HOFMAN, LF
    CLINICAL CHEMISTRY, 1993, 39 (01) : 66 - 71
  • [28] Quantification of derivatized phenylalanine and tyrosine in dried blood spots using liquid chromatography with tandem spectrometry for newborn screening of phenylketonuria
    Duh, Tsai-Hui
    Liang, Yu-Ching
    Shen, Po Tsun
    Ke, Yi-Wen
    Nian, Yan-Tian
    Liang, Shih-Shin
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2024, 30 (02) : 133 - 140
  • [29] Brain phenylalanine measurement in patients with phenylketonuria: A serious diagnostic method or just reading tea leaves?
    Bik-Multanowski, Miroslaw
    Pletrzyk, Jacek J.
    MOLECULAR GENETICS AND METABOLISM, 2007, 91 (03) : 297 - 298
  • [30] ABNORMAL TYROSINE AND PHENYLALANINE METABOLISM IN PATIENTS WITH TYROSYLURIA AND PHENYLKETONURIA - GAS-LIQUID CHROMATOGRAPHIC ANALYSIS OF URINARY METABOLITES
    WADMAN, SK
    VANDERHE.C
    KETTING, D
    VANSPRAN.FJ
    CLINICA CHIMICA ACTA, 1971, 34 (02) : 277 - &