Evaluation of volumetric blood collection devices for the measurement of phenylalanine and tyrosine to monitor patients with phenylketonuria

被引:16
|
作者
Carling, Rachel S. [1 ,2 ,5 ]
Emmett, Erin C. [2 ]
Moat, Stuart J. [3 ,4 ]
机构
[1] Kings Coll London, GKT Sch Med Educ, London, England
[2] Guys & St Thomas NHSFT, Biochem Sci, London, England
[3] Univ Hosp Wales, Dept Med Biochem Immunol & Toxicol, Cardiff, Wales
[4] Cardiff Univ, Univ Hosp Wales, Sch Med, Cardiff, Wales
[5] St Thomas Hosp, Biochem Sci, 4th Floor,North Wing,Westminster Bridge Rd, London SE1, England
关键词
Blood collection devices; Dried blood spots; DBS; Phenylalanine; Phenylketonuria; PKU; Microsampling; Tyrosine; Standardization; AMINO-ACIDS; HEMATOCRIT; PUNCH;
D O I
10.1016/j.cca.2022.08.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Measurement of dried blood spot (DBS) phenylalanine (Phe) is central to the monitoring of patients with phenylketonuria. However, the volume and hematocrit (Hct) of the blood applied to conventional DBS cards significantly affects analytical results. Volumetric blood collection devices are reported to be more accurate, precise and less prone to Hct effects.Methods: Accuracy, imprecision, effect of blood volume and Hct were evaluated for measurement of Phe and tyrosine using three volumetric devices and compared with the conventional PerkinElmer-226 filter-paper collection devices. i.e. conventional DBS cards. Applicability for use in a clinical laboratory was assessed qualitatively.Results: Blood volume did not impact on the performance of the volumetric devices; however, significant biases were observed with the conventional DBS card. A higher Hct introduced unacceptable bias for Neoteryx-Mitra and conventional DBS card. All devices had a mean relative standard deviation (RSD) <= 4.1 %, except for the Neoteryx-Mitra (<= 6.2 %). Relative to liquid blood, the mean biases of Phe for the various devices were-5.1 (HemaXis-DB10),-7.8 (Capitainer-qDBS),-12.0 (Neoteryx-Mitra) and-32.6 % (conventional DBS card).Conclusions: Introducing volumetric collection devices will overcome the significant pre-analytical issues asso-ciated with conventional DBS collection and improve the biochemical monitoring of patients with PKU.
引用
收藏
页码:157 / 166
页数:10
相关论文
共 50 条
  • [1] Validation and application of volumetric absorptive microsampling (VAMS) dried blood method for phenylalanine measurement in patients with phenylketonuria
    Gao, Lan
    Smith, Neil
    Kaushik, Diksha
    Milner, Sarah
    Kong, Ronald
    [J]. CLINICAL BIOCHEMISTRY, 2023, 116 : 65 - 74
  • [2] PHENYLALANINE AND TYROSINE METABOLISM IN PATIENTS WITH PHENYLKETONURIA
    BOSCOTT, RJ
    BICKEL, H
    [J]. BIOCHEMICAL JOURNAL, 1954, 56 (01) : R1 - R1
  • [3] Volumetric brain reductions in adult patients with phenylketonuria and their relationship with blood phenylalanine levels
    Pardo, Jessica
    Capdevila-Lacasa, Clara
    Segura, Barbara
    Pane, Adriana
    Montserrat, Cristina
    Forga-Visa, Maria de Tallo
    Moreno, Pedro J.
    Garrabou, Gloria
    Grau-Junyent, Josep M.
    Junque, Carme
    [J]. JOURNAL OF NEURODEVELOPMENTAL DISORDERS, 2024, 16 (01)
  • [4] Effect of BH4 on blood phenylalanine and tyrosine variations in patients with phenylketonuria
    van Wegberg, A. M. J.
    Evers, R. A. F.
    Burgerhof, J. G. M.
    van Dam, E.
    Heiner-Fokkema, M. R.
    Janssen, M. C. H.
    Vries, M. C. de
    van Spronsen, F. J.
    [J]. MOLECULAR GENETICS AND METABOLISM, 2021, 133 (01) : 49 - 55
  • [5] DETERMINATION OF PHENYLALANINE AND TYROSINE IN PERIPHERAL BLOOD AND ITS APPLICATION IN PHENYLKETONURIA
    Mo, Xi Ming
    Tang, Ai Guo
    [J]. CELL BIOLOGY INTERNATIONAL, 2008, 32 (03) : S61 - S61
  • [6] Biosensor used for measurement of blood phenylalanine for prevention of phenylketonuria
    Zhou, Z
    Wang, Z
    Guo, ZW
    Zhao, XN
    Guo, JY
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2002, : 684 - 687
  • [7] Noninvasive measurement of phenylalanine by iontophoretic extraction in patients with phenylketonuria
    Longo, N.
    Li, S. K.
    Yan, G.
    Kochambilli, R. P.
    Papangkorn, K.
    Berglund, D.
    Ghanem, A. -H.
    Ashurst, C. L.
    Ernst, S. L.
    Pasquali, M.
    Higuchi, W. I.
    [J]. JOURNAL OF INHERITED METABOLIC DISEASE, 2007, 30 (06) : 910 - 915
  • [8] NIGHT TERRORS IN TWO ADULTS WITH PHENYLKETONURIA: THE EFFECTS OF NORMALIZING BLOOD PHENYLALANINE AND BLOOD TYROSINE LEVELS
    Duncan, Laura
    Al Saif, Hind
    [J]. MOLECULAR GENETICS AND METABOLISM, 2019, 126 (03) : 298 - 298
  • [9] NIGHT TERRORS IN TWO ADULTS WITH PHENYLKETONURIA: THE EFFECTS OF NORMALIZING BLOOD PHENYLALANINE AND BLOOD TYROSINE LEVELS
    Duncan, Laura
    Al Saif, Hind
    [J]. MOLECULAR GENETICS AND METABOLISM, 2019, 127 (03) : 265 - 265
  • [10] Use of the Guthrie bacterial inhibition assay to monitor blood phenylalanine for dietary treatment of phenylketonuria
    Rohr, FJ
    Allred, EN
    Turner, M
    Simmons, J
    Levy, HL
    [J]. SCREENING, 1996, 4 (04): : 205 - 211