Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis

被引:96
|
作者
Mitarai, S. [1 ]
Okumura, M. [2 ]
Toyota, E. [3 ]
Yoshiyama, T. [2 ]
Aono, A. [4 ]
Sejimo, A. [5 ]
Azuma, Y. [4 ]
Sugahara, K. [5 ]
Nagasawa, T. [5 ]
Nagayama, N. [3 ]
Yamane, A. [3 ]
Yano, R. [2 ]
Kokuto, H. [2 ]
Morimoto, K. [2 ]
Ueyama, M. [2 ]
Kubota, M. [2 ]
Yi, R. [2 ]
Ogata, H. [2 ]
Kudoh, S. [2 ]
Mori, T. [1 ]
机构
[1] JATA, Res Inst TB, Bacteriol Div, Dept Mycobacterium Reference & Res, Tokyo 2048533, Japan
[2] JATA, Double Barred Cross Hosp, Dept Resp & Internal Med, Tokyo 2048533, Japan
[3] Tokyo Hosp, Natl Hosp Org, Dept Resp & Internal Med, Tokyo, Japan
[4] JATA, Double Barred Cross Hosp, Microbiol Lab, Tokyo 2048533, Japan
[5] Tokyo Hosp, Natl Hosp Org, Microbiol Lab, Tokyo, Japan
关键词
LAMP; tuberculosis; diagnosis; POLYMERASE-CHAIN-REACTION; HUMAN-IMMUNODEFICIENCY-VIRUS; MYCOBACTERIA DIRECT ASSAY; PULMONARY TUBERCULOSIS; RESPIRATORY SPECIMENS; CLINICAL-EVALUATION; SPUTUM SAMPLES; RIFAMPIN RESISTANCE; DEVELOPING-COUNTRY; AMPLICOR MTB;
D O I
10.5588/ijtld.10.0629
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
OBJECTIVE: A new loop-mediated isothermal amplification (LAMP) test kit, including a simple DNA extraction device for the detection of Mycobacterium tuberculosis complex, was developed for commercial use and evaluated for its usefulness in diagnosing tuberculosis (TB). DESIGN: The LAMP test was performed using untreated and N-acetyl-L-cysteine (NALC) NaOH-treated sputum specimen. The efficiency of the kit was compared with other conventional laboratory examinations, including other nucleic acid amplification (NAA) tests. RESULTS: The sensitivity of LAMP using raw sputum (direct LAMP) in smear- and culture-positive specimens was 98.2% (95% CI 94.9-99.4), while the sensitivity in smear-negative, culture-positive specimens was 55.6% (95% CI 43.4-68.0). The diagnostic sensitivity of direct LAMP for the diagnosis of individuals with TB was 88.2% (95% CI 81.4-92.7). The sensitivity values of direct LAMP were slightly, but not statistically significantly lower than those of Cobas Amplicor MTB and TRC Rapid MT, while the sensitivity of the LAMP test using NALC-NaOH treated sputum was significantly lower than other NAA tests (P < 0.05) for smear-negative, culture-positive specimens. The new commercial version of the LAMP kit was easy to handle and yielded results within 1 h of receiving sputum specimens. CONCLUSIONS: This test is considered a promising diagnostic tool for TB, even for peripheral laboratories with limited equipment, such as those in developing countries.
引用
收藏
页码:1211 / 1217
页数:7
相关论文
共 50 条
  • [41] Comparison of the Efficacies of Loop-Mediated Isothermal Amplification, Fluorescence Smear Microscopy and Culture for the Diagnosis of Tuberculosis
    George, Geojith
    Mony, Prem
    Kenneth, John
    [J]. PLOS ONE, 2011, 6 (06):
  • [42] Evaluation of three enzyme immunoassays and a loop-mediated isothermal amplification test for the laboratory diagnosis of Clostridium difficile infection
    M. J. Bruins
    E. Verbeek
    J. A. Wallinga
    L. E. S. Bruijnesteijn van Coppenraet
    E. J. Kuijper
    P. Bloembergen
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2012, 31 : 3035 - 3039
  • [43] Evaluation of Loop-Mediated Isothermal Amplification (LAMP) in Urine Samples for the Diagnosis of Imported Schistosomiasis
    Salas-Coronas, Joaquin
    Luzon-Garcia, Maria Pilar
    Crego-Vicente, Beatriz
    Soriano-Perez, Manuel Jesus
    Febrer-Sendra, Begona
    Vazquez-Villegas, Jose
    Diego, Juan Garcia-Bernalt
    Cabeza-Barrera, Isabel Maria
    Castillo-Fernandez, Nerea
    Muro, Antonio
    Bargues, Maria Dolores
    Fernandez-Soto, Pedro
    [J]. TROPICAL MEDICINE AND INFECTIOUS DISEASE, 2023, 8 (12)
  • [44] Evaluation of a commercial loop-mediated isothermal amplification assay for diagnosis of Bordetella pertussis infection
    Kamachi, Kazunari
    Moriuchi, Takumi
    Hiramatsu, Yukihiro
    Otsuka, Nao
    Shibayama, Keigo
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2017, 133 : 20 - 22
  • [45] Development and evaluation of a loop-mediated isothermal amplification assay for diagnosis of Cyprinid herpesvirus 2
    He, Junqiang
    Shi, Xiujie
    Yu, Li
    Zheng, Xiaocong
    Lan, Wensheng
    Jia, Peng
    Wang, Jinjin
    Liu, Hong
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2013, 194 (1-2) : 206 - 210
  • [46] A Comprehensive Evaluation of a Loop-Mediated Isothermal Amplification Assay for the Diagnosis of Pulmonary Tuberculosis in Children Using Bronchoalveolar Lavage Fluid
    Fan, Lichao
    Guan, Bo
    Cheng, Moxin
    Liu, Chang
    Tian, Yao
    Li, Ran
    Chen, Yu
    [J]. INFECTION AND DRUG RESISTANCE, 2022, 15 : 975 - 987
  • [47] Simple method for the detection of vibro parahaemolyticus by loop-mediated isothermal amplification
    Zhao, Xihong
    He, Xiaowei
    Yang, Liansheng
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238 : 274 - 274
  • [48] Evaluation of molecular inhibitors of loop-mediated isothermal amplification (LAMP)
    Nwe, May Khat
    Jangpromma, Nisachon
    Taemaitree, Lapatrada
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [49] Development and evaluation of a loop-mediated isothermal amplification assay for rapid and simple detection of Flavobacterium psychrophilum
    Fujiwara-Nagata, E.
    Eguchi, M.
    [J]. JOURNAL OF FISH DISEASES, 2009, 32 (10) : 873 - 881
  • [50] Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Zika Virus: A Review
    Ribeiro da Silva, Severino Jefferson
    Pardee, Keith
    Pena, Lindomar
    [J]. VIRUSES-BASEL, 2020, 12 (01):