Evaluation of Loop-Mediated Isothermal Amplification (LAMP) in Urine Samples for the Diagnosis of Imported Schistosomiasis

被引:0
|
作者
Salas-Coronas, Joaquin [1 ,2 ]
Luzon-Garcia, Maria Pilar [1 ]
Crego-Vicente, Beatriz [3 ]
Soriano-Perez, Manuel Jesus [1 ]
Febrer-Sendra, Begona [3 ]
Vazquez-Villegas, Jose [4 ]
Diego, Juan Garcia-Bernalt [3 ]
Cabeza-Barrera, Isabel Maria [1 ]
Castillo-Fernandez, Nerea [1 ]
Muro, Antonio [3 ]
Bargues, Maria Dolores [5 ,6 ]
Fernandez-Soto, Pedro [3 ]
机构
[1] Hosp Univ Poniente, Trop Med Unit, Almeria 04700, Spain
[2] Univ Almeria, Fac Hlth Sci, Dept Nursing Physiotherapy & Med, Almeria 04120, Spain
[3] Univ Salamanca, Biomed Res Inst Salamanca Res Ctr Trop Dis Univ Sa, Fac Pharm, Infect & Trop Dis Res Grp e INTRO, Salamanca 37007, Spain
[4] Dist Poniente Almeria, Trop Med Unit, Almeria 04700, Spain
[5] Univ Valencia, Fac Pharm, Dept Parasitol, Valencia 46100, Spain
[6] Inst Salud Carlos III, CIBER Enfermedades Infecciosas, Madrid 28029, Spain
关键词
schistosomiasis; diagnosis; LAMP; immunochromatographic rapid test; microscopy; latent class analysis; IMMIGRANTS;
D O I
10.3390/tropicalmed8120518
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Migratory flows and international travel are triggering an increase in imported cases of schistosomiasis in non-endemic countries. The present study aims to evaluate the effectiveness of the LAMP technique on patients' urine samples for the diagnosis of imported schistosomiasis in a non-endemic area in comparison to a commercial immunochromatographic test and microscopic examination of feces and urine. A prospective observational study was conducted in sub-Saharan migrants attending the Tropical Medicine Unit, Almeria, Spain. For schistosomiasis diagnosis, serum samples were tested using an immunochromatographic test (Schistosoma ICT IgG-IgM). Stool and urine samples were examined by microcopy. Urine samples were evaluated by combining three LAMP assays for the specific detection of Schistosoma mansoni, S. haematobium, and for the genus Schistosoma. To evaluate the diagnostic accuracy, a latent class analysis (LCA) was performed. In total, 115 patients were included (92.2% male; median age: 28.3 years). Of these, 21 patients (18.3%) were diagnosed with schistosomiasis confirmed by microscopy, with S. haematobium being the most frequent species identified (18/115; 15.7%). The Schistosoma ICT IgG-IgM test result was 100% positive and Schistosoma-LAMP was 61.9% positive, reaching as high as 72.2% for S. haematobium. The sensitivity and specificity estimated by LCA, respectively, were: 92% and 76% for Schistosoma ICT IgG-IgM, 68% and 44% for Schistosoma-LAMP, and 46% and 97% for microscopy. In conclusion, the Schistosoma-LAMP technique presented a higher sensitivity than microscopy for the diagnosis of imported urinary schistosomiasis, which could improve the diagnosis of active infection, both in referral centers and in centers with limited experience or scarce resources and infrastructure.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [2] MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
    Ocker, Ronja
    Prompunjai, Yongyut
    Chutipongvivate, Salakchit
    Karanis, Panagiotis
    REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2016, 58
  • [3] Evaluation of molecular inhibitors of loop-mediated isothermal amplification (LAMP)
    Nwe, May Khat
    Jangpromma, Nisachon
    Taemaitree, Lapatrada
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Rapid diagnosis of Zika virus through saliva and urine by Loop-mediated isothermal amplification (LAMP)
    Castro, Talita
    Sabalza, Maite
    Barber, Cheryl
    Abrams, William
    Da Costa, Antonio Charlys
    De Padua Milagres, Flavio Augusto
    Braz-Silva, Paulo Henrique
    Malamud, Daniel
    Gallottini, Marina
    JOURNAL OF ORAL MICROBIOLOGY, 2018, 10 (01)
  • [5] Development and evaluation of loop-mediated isothermal amplification (LAMP) for the rapid diagnosis of Penicillium marneffei in archived tissue samples
    Sun, Jiufeng
    Li, Xiqing
    Zeng, Hanxiang
    Xie, Zhi
    Lu, Changming
    Xi, Liyan
    de Hoog, Gert S.
    FEMS IMMUNOLOGY AND MEDICAL MICROBIOLOGY, 2010, 58 (03): : 381 - 388
  • [6] Early Detection of Leptospirosis in Cattle Urine Samples by Using Loop-Mediated Isothermal Amplification (LAMP) Method
    Widiasih, Dyah Ayu
    Susetya, Heru
    Rini, Widayanti
    2018 1ST INTERNATIONAL CONFERENCE ON BIOINFORMATICS, BIOTECHNOLOGY, AND BIOMEDICAL ENGINEERING - BIOINFORMATICS AND BIOMEDICAL ENGINEERING, 2018, : 83 - 86
  • [7] Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Zika Virus: A Review
    Ribeiro da Silva, Severino Jefferson
    Pardee, Keith
    Pena, Lindomar
    VIRUSES-BASEL, 2020, 12 (01):
  • [8] MOLECULAR DIAGNOSIS OF COLLETOTRICHUM KAHAWAE BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP)
    Tao, G.
    Cai, L.
    JOURNAL OF PLANT PATHOLOGY, 2013, 95 (03) : 519 - 524
  • [9] Loop-Mediated Isothermal Amplification (LAMP) Aids the Clinical Diagnosis of Pertussis
    Fujino, Motoko
    Suzuki, Eri
    Watanabe, Mineo
    Nakayama, Tetsuo
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2015, 68 (06) : 532 - 533
  • [10] Short Report: Evaluation of Loop-Mediated Isothermal Amplification (LAMP) for Malaria Diagnosis in a Field Setting
    Sirichaisinthop, Jeeraphat
    Buates, Sureemas
    Watanabe, Risa
    Han, Eun-Taek
    Suktawonjaroenpon, Wachira
    Krasaesub, Somporn
    Takeo, Satoru
    Tsuboi, Takafumi
    Sattabongkot, Jetsumon
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2011, 85 (04): : 594 - 596