Evaluation of Loop-Mediated Isothermal Amplification (LAMP) in Urine Samples for the Diagnosis of Imported Schistosomiasis

被引:0
|
作者
Salas-Coronas, Joaquin [1 ,2 ]
Luzon-Garcia, Maria Pilar [1 ]
Crego-Vicente, Beatriz [3 ]
Soriano-Perez, Manuel Jesus [1 ]
Febrer-Sendra, Begona [3 ]
Vazquez-Villegas, Jose [4 ]
Diego, Juan Garcia-Bernalt [3 ]
Cabeza-Barrera, Isabel Maria [1 ]
Castillo-Fernandez, Nerea [1 ]
Muro, Antonio [3 ]
Bargues, Maria Dolores [5 ,6 ]
Fernandez-Soto, Pedro [3 ]
机构
[1] Hosp Univ Poniente, Trop Med Unit, Almeria 04700, Spain
[2] Univ Almeria, Fac Hlth Sci, Dept Nursing Physiotherapy & Med, Almeria 04120, Spain
[3] Univ Salamanca, Biomed Res Inst Salamanca Res Ctr Trop Dis Univ Sa, Fac Pharm, Infect & Trop Dis Res Grp e INTRO, Salamanca 37007, Spain
[4] Dist Poniente Almeria, Trop Med Unit, Almeria 04700, Spain
[5] Univ Valencia, Fac Pharm, Dept Parasitol, Valencia 46100, Spain
[6] Inst Salud Carlos III, CIBER Enfermedades Infecciosas, Madrid 28029, Spain
关键词
schistosomiasis; diagnosis; LAMP; immunochromatographic rapid test; microscopy; latent class analysis; IMMIGRANTS;
D O I
10.3390/tropicalmed8120518
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Migratory flows and international travel are triggering an increase in imported cases of schistosomiasis in non-endemic countries. The present study aims to evaluate the effectiveness of the LAMP technique on patients' urine samples for the diagnosis of imported schistosomiasis in a non-endemic area in comparison to a commercial immunochromatographic test and microscopic examination of feces and urine. A prospective observational study was conducted in sub-Saharan migrants attending the Tropical Medicine Unit, Almeria, Spain. For schistosomiasis diagnosis, serum samples were tested using an immunochromatographic test (Schistosoma ICT IgG-IgM). Stool and urine samples were examined by microcopy. Urine samples were evaluated by combining three LAMP assays for the specific detection of Schistosoma mansoni, S. haematobium, and for the genus Schistosoma. To evaluate the diagnostic accuracy, a latent class analysis (LCA) was performed. In total, 115 patients were included (92.2% male; median age: 28.3 years). Of these, 21 patients (18.3%) were diagnosed with schistosomiasis confirmed by microscopy, with S. haematobium being the most frequent species identified (18/115; 15.7%). The Schistosoma ICT IgG-IgM test result was 100% positive and Schistosoma-LAMP was 61.9% positive, reaching as high as 72.2% for S. haematobium. The sensitivity and specificity estimated by LCA, respectively, were: 92% and 76% for Schistosoma ICT IgG-IgM, 68% and 44% for Schistosoma-LAMP, and 46% and 97% for microscopy. In conclusion, the Schistosoma-LAMP technique presented a higher sensitivity than microscopy for the diagnosis of imported urinary schistosomiasis, which could improve the diagnosis of active infection, both in referral centers and in centers with limited experience or scarce resources and infrastructure.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Rapid and sensitive diagnosis of adenoviral keratoconjunctivitis by loop-mediated isothermal amplification (LAMP) method
    Wakabayashi, T
    Yamashita, R
    Kakita, T
    Kakita, M
    Oshika, T
    CURRENT EYE RESEARCH, 2004, 29 (4-5) : 219 - 224
  • [22] Loop-Mediated Isothermal Amplification (LAMP) for the Detection of Salmonella in Food
    Kokkinos, P. A.
    Ziros, P. G.
    Bellou, M.
    Vantarakis, A.
    FOOD ANALYTICAL METHODS, 2014, 7 (02) : 512 - 526
  • [23] Rapid and Sensitive Diagnosis of Porcine Parvovirus by Loop-mediated Isothermal Amplification (LAMP) Method
    Qu, Guanggang
    Fu, Shijun
    Shen, Ning
    Wang, Jinliang
    Xiao, Yueqiang
    Guan, Yu
    Tang, Na
    Chen, Lei
    Gao, Sanyang
    Shen, Zhiqiang
    JOURNAL OF APPLIED ANIMAL RESEARCH, 2010, 37 (01) : 113 - 116
  • [24] Isothermal loop-mediated amplification (lamp) for diagnosis of contagious bovine pleuro-pneumonia
    Mair, Georg
    Vilei, Edy M.
    Wade, Abel
    Frey, Joachim
    Unger, Hermann
    BMC VETERINARY RESEARCH, 2013, 9
  • [25] Isothermal loop-mediated amplification (lamp) for diagnosis of contagious bovine pleuro-pneumonia
    Georg Mair
    Edy M Vilei
    Abel Wade
    Joachim Frey
    Hermann Unger
    BMC Veterinary Research, 9
  • [26] Rapid and sensitive diagnosis of adenoviral keratoconjunctivitis by loop-mediated isothermal amplification (LAMP) method
    Wakabayashi, T
    Yamashita, R
    Kakita, T
    Kakita, M
    Oshika, T
    CURRENT EYE RESEARCH, 2004, 28 (06) : 445 - 450
  • [27] DEVELOPMENT AND EVALUATION OF A LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) ASSAY FOR THE DETECTION OF HAEMONCHUS CONTORTUS IN GOAT FECAL SAMPLES
    Yang, X.
    Qi, M. W.
    Zhang, Z. Z.
    Gao, C.
    Wang, C. Q.
    Lei, W. Q.
    Tan, L.
    Zhao, J. L.
    Fang, R.
    Hu, M.
    JOURNAL OF PARASITOLOGY, 2017, 103 (02) : 161 - 167
  • [28] Rapid diagnosis of Theileria annulata by colorimetric loop-mediated isothermal amplification (LAMP) assay
    Paliwal, Sanjhi
    Sudan, Vikrant
    Shanker, Daya
    Srivastava, Mukesh
    VETERINARY PARASITOLOGY, 2020, 285
  • [29] Loop-mediated isothermal amplification (TB-lamp): a step forward in the diagnosis of tuberculosis?
    Saiyed, Hanieya
    Fatima, Sarosh
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2017, 67 (03) : 489 - 489
  • [30] First report on optimization of loop-mediated isothermal amplification (LAMP) for the diagnosis of Babesia felis
    Salim, Muhammad Awais
    Akhtar, Raheela
    Lateef, Muhammad
    Rashid, Muhammad Imran
    Akbar, Haroon
    Shehzad, Wasim
    Akhtar, Fareeha
    Islam, Saher
    Farooqi, Shahid Hussain
    Durrani, Uzma Farid
    INDIAN JOURNAL OF ANIMAL RESEARCH, 2018, 52 (03) : 401 - 404