MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND

被引:7
|
作者
Ocker, Ronja [1 ]
Prompunjai, Yongyut [2 ]
Chutipongvivate, Salakchit [2 ]
Karanis, Panagiotis [3 ,4 ]
机构
[1] Univ Cologne, Sch Med, Cologne, Germany
[2] Minist Publ Hlth Med Sci, Dept Med Sci, Reg Med Sci Ctr 3, Chon Buri, Thailand
[3] Qinghai Univ, Thousand Talent Plan Chinese Govt 1, Ctr Biomed & Infect Dis, Qinghai Acad Anim & Vet Sci, 1 Weier Rd, Xining 810016, Qinghai Provinc, Peoples R China
[4] Qinghai Univ, Qinghai Med Sch, Qinghai Biol Sci Garden, 1 Weier Rd, Xining 810016, Qinghai Provinc, Peoples R China
关键词
Malaria; Plasmodium; Molecular Diagnosis; LAMP; Thailand; VISUAL DETECTION; BLOOD; PCR; INFECTIONS; PARASITES; SENSITIVITY; MICROSCOPY; HUMANS; ASSAY;
D O I
10.1590/S1678-9946201658027
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The loop-mediated isothermal amplification method (LAMP) is a recently developed molecular technique that amplifies nucleic acid under isothermal conditions. For malaria diagnosis, 150 blood samples from consecutive febrile malaria patients, and healthy subjects were screened in Thailand. Each sample was diagnosed by LAMP, microscopy and nested polymerase chain reaction (nPCR), using nPCR as the gold standard. Malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum specific assays in parallel. For the genus Plasmodium, microscopy showed a sensitivity and specificity of 100%, while LAMP presented 99% of sensitivity and 93% of specificity. For P. falciparum, microscopy had a sensitivity of 95%, and LAMP of 90%, regarding the specificity; and microscopy presented 93% and LAMP 97% of specificity. The results of the genus-specific LAMP technique were highly consistent with those of nPCR and the sensitivity of P. falciparum detection was only marginally lower.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria
    Paris, D.
    Imwong, M.
    Faiz, M.
    Hasan, M.
    Bin Yunus, E.
    Silamut, K.
    Lee, S.
    Day, N.
    Dondorp, A.
    [J]. TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2007, 12 : 129 - 129
  • [2] Loop-mediated isothermal PCR (LAMP) for the diagnosis of falciparum malaria
    Paris, Daniel H.
    Imwong, Mallika
    Faiz, Abul M.
    Hasan, Mahtabuddin
    Bin Yunus, Entran
    Silamut, Kamolrat
    Lee, Sue J.
    Day, Nicholas P. J.
    Dondorp, Arjen M.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2007, 77 (05): : 972 - 976
  • [3] Short Report: Evaluation of Loop-Mediated Isothermal Amplification (LAMP) for Malaria Diagnosis in a Field Setting
    Sirichaisinthop, Jeeraphat
    Buates, Sureemas
    Watanabe, Risa
    Han, Eun-Taek
    Suktawonjaroenpon, Wachira
    Krasaesub, Somporn
    Takeo, Satoru
    Tsuboi, Takafumi
    Sattabongkot, Jetsumon
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2011, 85 (04): : 594 - 596
  • [4] Loop-mediated isothermal amplification test for the molecular diagnosis of malaria
    Han, Eun-Taek
    [J]. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2013, 13 (02) : 205 - 218
  • [5] Loop-Mediated Isothermal Amplification Assay for Rapid Diagnosis of Malaria Infections in an Area of Endemicity in Thailand
    Sattabongkot, Jetsumon
    Tsuboi, Takafumi
    Han, Eun-Taek
    Bantuchai, Sirasate
    Buates, Sureemas
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (05) : 1471 - 1477
  • [6] Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Zika Virus: A Review
    Ribeiro da Silva, Severino Jefferson
    Pardee, Keith
    Pena, Lindomar
    [J]. VIRUSES-BASEL, 2020, 12 (01):
  • [7] MOLECULAR DIAGNOSIS OF COLLETOTRICHUM KAHAWAE BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP)
    Tao, G.
    Cai, L.
    [J]. JOURNAL OF PLANT PATHOLOGY, 2013, 95 (03) : 519 - 524
  • [8] Loop-Mediated Isothermal Amplification (LAMP) Aids the Clinical Diagnosis of Pertussis
    Fujino, Motoko
    Suzuki, Eri
    Watanabe, Mineo
    Nakayama, Tetsuo
    [J]. JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2015, 68 (06) : 532 - 533
  • [9] Added value of loop-mediated isothermal amplification technology (LAMP) in real life for the diagnosis of malaria in travellers
    Burdino, Elisa
    Calleri, Guido
    Ghisetti, Valeria
    [J]. JOURNAL OF TRAVEL MEDICINE, 2019, 26 (07)
  • [10] Accuracy of Loop-Mediated Isothermal Amplification for Diagnosis of Human Leptospirosis in Thailand
    Sonthayanon, Piengchan
    Chierakul, Wirongrong
    Wuthiekanun, Vanaporn
    Thaipadungpanit, Janjira
    Kalambaheti, Thareerat
    Boonsilp, Siriphan
    Amornchai, Premjit
    Smythe, Lee D.
    Limmathurotsakul, Direk
    Day, Nicholas P.
    Peacock, Sharon J.
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2011, 84 (04): : 614 - 620