Comparison of the Efficacies of Loop-Mediated Isothermal Amplification, Fluorescence Smear Microscopy and Culture for the Diagnosis of Tuberculosis

被引:39
|
作者
George, Geojith [1 ]
Mony, Prem [2 ]
Kenneth, John [1 ]
机构
[1] St Johns Res Inst, Div Infect Dis, Bangalore, Karnataka, India
[2] St Johns Res Inst, Div Epidemiol & Biostat, Bangalore, Karnataka, India
来源
PLOS ONE | 2011年 / 6卷 / 06期
关键词
ACID-FAST BACILLI; MYCOBACTERIUM-TUBERCULOSIS; PULMONARY TUBERCULOSIS; LAMP ASSAY; SPUTUM; IDENTIFICATION; FEASIBILITY; SENSITIVITY; ACCURACY; TOOLS;
D O I
10.1371/journal.pone.0021007
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Despite the advent of novel diagnostic techniques, smear microscopy remains as the most practical test available in resource-limited settings for tuberculosis (TB) diagnosis. Due to the low sensitivity of microscopy and the long time required for culture, feasible and accessible rapid diagnostic methods are urgently needed. Loop-mediated Isothermal Amplification (LAMP) is a promising nucleic-acid amplification assay, which could be accessible, cost-effective and more suited for use with unpurified samples. Methodology/Principal Findings: In the current study, the objective was to assess the efficacy of a LAMP assay for tuberculosis compared with fluorescence smear microscopy as well as Lowenstein-Jensen (LJ) and Mycobacteria Growth Indicator Tube (MGIT) cultures for the diagnosis of pulmonary tuberculosis using sputum samples. Smear microscopy and culture were performed for decontaminated and concentrated sputum from TB suspects and the LAMP was also performed on these specimens. The LAMP and smear microscopy were compared, in series and in parallel, to culture. LAMP and smear microscopy showed sensitivities of 79.5% and 82.1% respectively and specificities of 93.8% and 96.9% respectively, compared to culture. LAMP and smear in series had sensitivity and specificity of 79.5% and 100.0% respectively. LAMP and smear in parallel had sensitivity and specificity of 82.1% and 90.6% respectively. Conclusions/Significance: The overall efficacies of LAMP and fluorescence smear microscopy in the current study were high and broadly similar. LAMP and smear in series had high specificity (100.0%) and can be used as a rule-in test combination. However, the performance of LAMP in smear negative samples was found to be insufficient.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis
    Gelaw, Baye
    Shiferaw, Yitayal
    Alemayehu, Marta
    Bashaw, Abate Assefa
    [J]. BMC INFECTIOUS DISEASES, 2017, 17
  • [2] Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis
    Baye Gelaw
    Yitayal Shiferaw
    Marta Alemayehu
    Abate Assefa Bashaw
    [J]. BMC Infectious Diseases, 17
  • [3] Comparison of Loop-Mediated Isothermal Amplification, Microscopy, Culture, and PCR for Diagnosis of Pulmonary Tuberculosis
    Phetsuksiri, Benjawan
    Rudeeaneksin, Janisara
    Srisungngam, Sopa
    Bunchoo, Supranee
    Klayut, Wiphat
    Nakajima, Chie
    Hamada, Shigeyuki
    Suzuki, Yasuhiko
    [J]. JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2020, 73 (04) : 272 - 277
  • [4] A loop-mediated isothermal amplification assay for the diagnosis of pulmonary tuberculosis
    Sharma, G.
    Tewari, R.
    Dhatwalia, S. K.
    Yadav, R.
    Behera, D.
    Sethi, S.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2019, 68 (03) : 219 - 225
  • [5] Loop-mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis
    Kumar, Parveen
    Pandya, Deepal
    Singh, Niti
    Behera, Digambar
    Aggarwal, Praveen
    Singh, Sarman
    [J]. JOURNAL OF INFECTION, 2014, 69 (06) : 607 - 615
  • [6] Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis
    Mitarai, S.
    Okumura, M.
    Toyota, E.
    Yoshiyama, T.
    Aono, A.
    Sejimo, A.
    Azuma, Y.
    Sugahara, K.
    Nagasawa, T.
    Nagayama, N.
    Yamane, A.
    Yano, R.
    Kokuto, H.
    Morimoto, K.
    Ueyama, M.
    Kubota, M.
    Yi, R.
    Ogata, H.
    Kudoh, S.
    Mori, T.
    [J]. INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2011, 15 (09) : 1211 - 1217
  • [7] Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries
    Boehme, Catharina C.
    Nabeta, Pamela
    Henostroza, German
    Raqib, Rubhana
    Rahim, Zeaur
    Gerhardt, Martina
    Sanga, Erica
    Hoelscher, Michael
    Notomi, Tsugunori
    Hase, Tetsu
    Perkins, Mark D.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (06) : 1936 - 1940
  • [8] Real-time fluorescence Loop-Mediated Isothermal Amplification (LAMP) for rapid and reliable diagnosis of pulmonary tuberculosis
    Cao, Donglin
    Hu, Liangshan
    Lin, Maorui
    Li, Mingyou
    Ye, Zebing
    Sun, Hongtao
    Huang, Jiwei
    Yang, Huawen
    Tian, Junzhang
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 109 : 74 - 78
  • [9] Diagnosis of Brugian Filariasis by Loop-Mediated Isothermal Amplification
    Poole, Catherine B.
    Tanner, Nathan A.
    Zhang, Yinhua
    Evans, Thomas C., Jr.
    Carlow, Clotilde K. S.
    [J]. PLOS NEGLECTED TROPICAL DISEASES, 2012, 6 (12):
  • [10] Loop-mediated isothermal amplification as alternative to PCR for the diagnosis of extra-pulmonary tuberculosis
    Joon, D.
    Nimesh, M.
    Saluja, D.
    [J]. INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2015, 19 (08) : 986 - 991