Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis

被引:15
|
作者
Gelaw, Baye [1 ]
Shiferaw, Yitayal [2 ,3 ]
Alemayehu, Marta [1 ]
Bashaw, Abate Assefa [1 ]
机构
[1] Univ Gondar, Sch Biomed & Lab Sci, Dept Med Microbiol, CMHS, POB 196, Gondar, Ethiopia
[2] Univ Addis Ababa, Dept Microbiol Parasitol & Immunol, Fac Med, Addis Ababa, Ethiopia
[3] Flinders Univ S Australia, Sch Med, Adelaide, SA 5042, Australia
关键词
Loop-mediated isothermal amplification; Tuberculosis; Smear microscopy; Culture; PULMONARY TUBERCULOSIS; LAMP;
D O I
10.1186/s12879-016-2140-8
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M. tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. Method: A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. Results: A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (kappa = 0.83, P-value <= 0.0001). Conclusions: TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis
    Baye Gelaw
    Yitayal Shiferaw
    Marta Alemayehu
    Abate Assefa Bashaw
    [J]. BMC Infectious Diseases, 17
  • [2] Comparison of the Efficacies of Loop-Mediated Isothermal Amplification, Fluorescence Smear Microscopy and Culture for the Diagnosis of Tuberculosis
    George, Geojith
    Mony, Prem
    Kenneth, John
    [J]. PLOS ONE, 2011, 6 (06):
  • [3] Comparison of Loop-Mediated Isothermal Amplification, Microscopy, Culture, and PCR for Diagnosis of Pulmonary Tuberculosis
    Phetsuksiri, Benjawan
    Rudeeaneksin, Janisara
    Srisungngam, Sopa
    Bunchoo, Supranee
    Klayut, Wiphat
    Nakajima, Chie
    Hamada, Shigeyuki
    Suzuki, Yasuhiko
    [J]. JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2020, 73 (04) : 272 - 277
  • [4] Diagnostic accuracy of the loop-mediated isothermal amplification assay for extrapulmonary tuberculosis: A meta-analysis
    Yu, Guocan
    Shen, Yanqin
    Zhong, Fangming
    Ye, Bo
    Yang, Jun
    Chen, Gang
    [J]. PLOS ONE, 2018, 13 (06):
  • [5] Diagnostic accuracy of loop-mediated isothermal amplification assay for extra-pulmonary tuberculosis in Indian population
    Rajput, Roopali
    Singh, Paras
    Sarin, Rohit
    Sethi, Prabhpreet
    Sharma, Sangeeta
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2019, 158 : 59 - 65
  • [6] Diagnostic Accuracy of Loop-Mediated Isothermal Amplification (TB-LAMP) for Tuberculosis in Children
    Promsena, Pathariya
    Jantarabenjakul, Watsamon
    Suntarattiwong, Piyarat
    Sudjaritruk, Tavitiya
    Anugulruengkitt, Suvaporn
    Rotcheewaphan, Suwatchareeporn
    Petsong, Suthidee
    Sawangsinth, Panadda
    Sophonphan, Jiratchaya
    Tawan, Monta
    Moonwong, Juthamanee
    Puthanakit, Thanyawee
    [J]. JOURNAL OF THE PEDIATRIC INFECTIOUS DISEASES SOCIETY, 2022, 11 (01) : 9 - 15
  • [7] A loop-mediated isothermal amplification assay for the diagnosis of pulmonary tuberculosis
    Sharma, G.
    Tewari, R.
    Dhatwalia, S. K.
    Yadav, R.
    Behera, D.
    Sethi, S.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2019, 68 (03) : 219 - 225
  • [8] Detection of Mycobacterium Tuberculosis by Loop-Mediated Isothermal Amplification Assay
    Ahn, Young-Chang
    Nam, Youn-Hyoung
    Park, Su-Min
    Cho, Min-Ho
    Seo, Jae-Won
    Yoon, Il-Kyu
    Park, Yong Hyun
    Jang, Won-Cheoul
    [J]. JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2008, 52 (03): : 273 - 280
  • [9] Diagnostic test accuracy of loop-mediated isothermal amplification assay for Mycobacterium tuberculosis: systematic review and meta-analysis
    Nagai, Kenjiro
    Horita, Nobuyuki
    Yamamoto, Masaki
    Tsukahara, Toshinori
    Nagakura, Hideyuki
    Tashiro, Ken
    Shibata, Yuji
    Watanabe, Hiroki
    Nakashima, Kentaro
    Ushio, Ryota
    Ikeda, Misako
    Narita, Atsuya
    Kanai, Akinori
    Sato, Takashi
    Kaneko, Takeshi
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [10] Diagnostic test accuracy of loop-mediated isothermal amplification assay for Mycobacterium tuberculosis: systematic review and meta-analysis
    Kenjiro Nagai
    Nobuyuki Horita
    Masaki Yamamoto
    Toshinori Tsukahara
    Hideyuki Nagakura
    Ken Tashiro
    Yuji Shibata
    Hiroki Watanabe
    Kentaro Nakashima
    Ryota Ushio
    Misako Ikeda
    Atsuya Narita
    Akinori Kanai
    Takashi Sato
    Takeshi Kaneko
    [J]. Scientific Reports, 6