Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis

被引:15
|
作者
Gelaw, Baye [1 ]
Shiferaw, Yitayal [2 ,3 ]
Alemayehu, Marta [1 ]
Bashaw, Abate Assefa [1 ]
机构
[1] Univ Gondar, Sch Biomed & Lab Sci, Dept Med Microbiol, CMHS, POB 196, Gondar, Ethiopia
[2] Univ Addis Ababa, Dept Microbiol Parasitol & Immunol, Fac Med, Addis Ababa, Ethiopia
[3] Flinders Univ S Australia, Sch Med, Adelaide, SA 5042, Australia
关键词
Loop-mediated isothermal amplification; Tuberculosis; Smear microscopy; Culture; PULMONARY TUBERCULOSIS; LAMP;
D O I
10.1186/s12879-016-2140-8
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M. tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. Method: A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. Results: A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (kappa = 0.83, P-value <= 0.0001). Conclusions: TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications
    Francois, Patrice
    Tangomo, Manuela
    Hibbs, Jonathan
    Bonetti, Eve-Julie
    Boehme, Catharina C.
    Notomi, Tsugunori
    Perkins, Mark D.
    Schrenzel, Jacques
    [J]. FEMS IMMUNOLOGY AND MEDICAL MICROBIOLOGY, 2011, 62 (01): : 41 - 48
  • [22] Diagnostic potential of multi-targeted LAMP (loop-mediated isothermal amplification) for osteoarticular tuberculosis
    Sharma, Kusum
    Sharma, Megha
    Batra, Nitya
    Sharma, Aman
    Dhillon, Mandeep Singh
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (02) : 361 - 365
  • [23] Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture
    Sung, Ji-Hee
    Cha, Hyun-Hwa
    Lee, Nan-Young
    Lee, Won-Ki
    Choi, Yeseul
    Han, Hyung-Soo
    Lee, Yoo-Young
    Chong, Gun-Oh
    Seong, Won-Joon
    [J]. DIAGNOSTICS, 2022, 12 (07)
  • [24] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [25] Loop-mediated isothermal amplification of DNA
    Notomi, Tsugunori
    Okayama, Hiroto
    Masubuchi, Harumi
    Yonekawa, Toshihiro
    Watanabe, Keiko
    Amino, Nobuyuki
    Hase, Tetsu
    [J]. NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
  • [26] The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture
    Phetsuksiri, Benjawan
    Klayut, Wiphat
    Rudeeaneksin, Janisara
    Srisungngam, Sopa
    Bunchoo, Supranee
    Toonkomdang, Sarawut
    Wongchai, Thanee
    Nakajima, Chie
    Suzuki, Yasuhiko
    [J]. REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2020, 62 : 1 - 6
  • [27] Rapid detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification assay
    Yuan, Xin
    Bai, Changqing
    Cui, Qian
    Zhang, Han
    Yuan, Jing
    Niu, Kaiwen
    Feng, Yuzhong
    Jin, Xin
    Li, Puyuan
    Liu, Huiying
    [J]. MEDICINE, 2018, 97 (25)
  • [28] Development of Loop-Mediated Isothermal Amplification Assay for Detection of Entamoeba histolytica
    Liang, Shih-Yu
    Chan, Yun-Hsien
    Hsia, Kan-Tai
    Lee, Jing-Lun
    Kuo, Ming-Chu
    Hwa, Kuo-Yuan
    Chan, Chi-Wen
    Chiang, Ting-Yi
    Chen, Jung-Sheng
    Wu, Fang-Tzy
    Ji, Dar-Der
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) : 1892 - 1895
  • [29] Development of a Loop-Mediated Isothermal Amplification Assay to Detect Fusarium oxysporum
    Lu, Chenchen
    Dai, Tingting
    Zhang, HaiFeng
    Wang, YuanChao
    Zheng, XiaoBo
    [J]. JOURNAL OF PHYTOPATHOLOGY, 2015, 163 (01) : 63 - 66
  • [30] Development of a loop-mediated isothermal amplification assay for the detection of porcine hokovirus
    Li, Bin
    Sun, Bing
    Du, Lu-ping
    Mao, Ai-hua
    Wen, Li-bin
    Ni, Yan-xiu
    Zhang, Xue-han
    He, Kong-wang
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2013, 193 (02) : 415 - 418