Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis

被引:96
|
作者
Mitarai, S. [1 ]
Okumura, M. [2 ]
Toyota, E. [3 ]
Yoshiyama, T. [2 ]
Aono, A. [4 ]
Sejimo, A. [5 ]
Azuma, Y. [4 ]
Sugahara, K. [5 ]
Nagasawa, T. [5 ]
Nagayama, N. [3 ]
Yamane, A. [3 ]
Yano, R. [2 ]
Kokuto, H. [2 ]
Morimoto, K. [2 ]
Ueyama, M. [2 ]
Kubota, M. [2 ]
Yi, R. [2 ]
Ogata, H. [2 ]
Kudoh, S. [2 ]
Mori, T. [1 ]
机构
[1] JATA, Res Inst TB, Bacteriol Div, Dept Mycobacterium Reference & Res, Tokyo 2048533, Japan
[2] JATA, Double Barred Cross Hosp, Dept Resp & Internal Med, Tokyo 2048533, Japan
[3] Tokyo Hosp, Natl Hosp Org, Dept Resp & Internal Med, Tokyo, Japan
[4] JATA, Double Barred Cross Hosp, Microbiol Lab, Tokyo 2048533, Japan
[5] Tokyo Hosp, Natl Hosp Org, Microbiol Lab, Tokyo, Japan
关键词
LAMP; tuberculosis; diagnosis; POLYMERASE-CHAIN-REACTION; HUMAN-IMMUNODEFICIENCY-VIRUS; MYCOBACTERIA DIRECT ASSAY; PULMONARY TUBERCULOSIS; RESPIRATORY SPECIMENS; CLINICAL-EVALUATION; SPUTUM SAMPLES; RIFAMPIN RESISTANCE; DEVELOPING-COUNTRY; AMPLICOR MTB;
D O I
10.5588/ijtld.10.0629
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
OBJECTIVE: A new loop-mediated isothermal amplification (LAMP) test kit, including a simple DNA extraction device for the detection of Mycobacterium tuberculosis complex, was developed for commercial use and evaluated for its usefulness in diagnosing tuberculosis (TB). DESIGN: The LAMP test was performed using untreated and N-acetyl-L-cysteine (NALC) NaOH-treated sputum specimen. The efficiency of the kit was compared with other conventional laboratory examinations, including other nucleic acid amplification (NAA) tests. RESULTS: The sensitivity of LAMP using raw sputum (direct LAMP) in smear- and culture-positive specimens was 98.2% (95% CI 94.9-99.4), while the sensitivity in smear-negative, culture-positive specimens was 55.6% (95% CI 43.4-68.0). The diagnostic sensitivity of direct LAMP for the diagnosis of individuals with TB was 88.2% (95% CI 81.4-92.7). The sensitivity values of direct LAMP were slightly, but not statistically significantly lower than those of Cobas Amplicor MTB and TRC Rapid MT, while the sensitivity of the LAMP test using NALC-NaOH treated sputum was significantly lower than other NAA tests (P < 0.05) for smear-negative, culture-positive specimens. The new commercial version of the LAMP kit was easy to handle and yielded results within 1 h of receiving sputum specimens. CONCLUSIONS: This test is considered a promising diagnostic tool for TB, even for peripheral laboratories with limited equipment, such as those in developing countries.
引用
收藏
页码:1211 / 1217
页数:7
相关论文
共 50 条
  • [1] Evaluation and validation of a loop-mediated isothermal amplification test kit for detection of Hymenoscyphus fraxineus
    Harrison, Catherine
    Tomlinson, Jenny
    Ostoja-Starzewska, Sioban
    Boonham, Neil
    [J]. EUROPEAN JOURNAL OF PLANT PATHOLOGY, 2017, 149 (02) : 253 - 259
  • [2] Evaluation and validation of a loop-mediated isothermal amplification test kit for detection of Hymenoscyphus fraxineus
    Catherine Harrison
    Jenny Tomlinson
    Sioban Ostoja-Starzewska
    Neil Boonham
    [J]. European Journal of Plant Pathology, 2017, 149 : 253 - 259
  • [3] A loop-mediated isothermal amplification assay for the diagnosis of pulmonary tuberculosis
    Sharma, G.
    Tewari, R.
    Dhatwalia, S. K.
    Yadav, R.
    Behera, D.
    Sethi, S.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2019, 68 (03) : 219 - 225
  • [4] Loop-Mediated Isothermal Amplification test for the diagnosis of pertussis in Japan
    Nawa, Nobutoshi
    [J]. VACCINE, 2018, 36 (06) : 771 - 771
  • [5] Loop-mediated isothermal amplification test for the molecular diagnosis of malaria
    Han, Eun-Taek
    [J]. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2013, 13 (02) : 205 - 218
  • [6] Loop-mediated isothermal amplification assay for rapid and sensitive diagnosis of tuberculosis
    Kumar, Parveen
    Pandya, Deepal
    Singh, Niti
    Behera, Digambar
    Aggarwal, Praveen
    Singh, Sarman
    [J]. JOURNAL OF INFECTION, 2014, 69 (06) : 607 - 615
  • [7] EVALUATION OF LOOP-MEDIATED ISOTHERMAL AMPLIFICATION TEST KIT (TB-LAMP) FOR THE DIAGNOSIS OF PULMONARY TUBERCULOSIS IN A TERTIARY HOSPITAL IN ILOILO CITY: RETROSPECTIVE STUDY
    Tabuena, Rollin P.
    Landong, Jiggy Leonard F.
    Tabuena, Ma. Daisy P.
    Alcantara, Earl Joshua G.
    Anayan, Ma. Theresa Crisanta L.
    [J]. CHEST, 2023, 164 (04) : 776A - 776A
  • [8] Evaluation of a Loop-Mediated Isothermal Amplification (LAMP) kit as a molecular diagnostic test for congenital chagas disease
    Flores-Chavez, M. D.
    Besuschio, S. A.
    Picado, A.
    Ibanez, I.
    Wehrendt, D. X.
    Perez, P.
    Abras, A.
    Ballart, C.
    Gallego, M.
    Munoz, C.
    Ndung'u, J. M.
    Schijman, A. G.
    [J]. TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2017, 22 : 119 - 119
  • [9] EVALUATION OF A LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) KIT AS A MOLECULAR DIAGNOSTIC TEST FOR CONGENITAL CHAGAS DISEASE
    Picado, Albert
    Besuschio, Susana
    Ibanez, Ismael
    Cruz, Israel
    Benatar, Alejandro
    Gallego, Montserrat
    Munoz, Carme
    Ndung'u, Joseph
    Schijman, Alejandro
    Flores-Chavez, Maria
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 99 (04): : 445 - 445
  • [10] Multicenter evaluation of a real-time loop-mediated isothermal amplification (RealAmp) test for rapid diagnosis of Mycobacterium tuberculosis
    Ou, Xichao
    Wang, Shengfen
    Dong, Haiyan
    Pang, Yu
    Li, Qiang
    Xia, Hui
    Qu, Yan
    Zhang, Zhiying
    Li, Junchen
    Zhang, Jack
    Huan, Shitong
    Chin, Daniel P.
    Zhao, Yanlin
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2016, 129 : 39 - 43