A review of the image segmentation and registration methods in liver motion correction in C-arm perfusion imaging

被引:0
|
作者
Haseljic, Hana [1 ]
Frysch, Robert [1 ]
Kulvait, Vojtech [1 ]
Rose, Georg [1 ]
机构
[1] Otto von Guericke Univ, Inst Med Engn & Res Campus STIMUIATE, Univ Pl 2, D-39106 Magdeburg, Germany
关键词
C-arm; perfusion imaging; motion correction; image registration;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The C-arm perfusion imaging is not yet the standard part for liver cancer diagnosis and intraoperative measurements. The number of multiple rotations of C-arm depends on the total angle range resulting in large number of projections. Usually most of the liver disease features can be visible on CT images. However, the breathing and other liver surrounding organs motion during the acquisition can cause artifacts or missing important data on reconstructed CT images. In C-arm systems this is the consequence of the slow rotation. This paper gives an overview of existing motion correction algorithms used in medical imaging. These algorithms are based on image segmentation and registration.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Cerebral CT Perfusion Using an Interventional C-Arm Imaging System: Cerebral Blood Flow Measurements
    Ganguly, A.
    Fieselmann, A.
    Marks, M.
    Rosenberg, J.
    Boese, J.
    Deuerling-Zheng, Y.
    Straka, M.
    Zaharchuk, G.
    Bammer, R.
    Fahrig, R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (08) : 1525 - 1531
  • [32] Using a registration based motion correction algorithm (RMCA) to correct for respiratory motion during myocardial perfusion Imaging
    Redgate, S.
    Tindale, W. B.
    Barber, D. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S146 - S146
  • [33] Kinect-Based Correction of Overexposure Artifacts in Knee Imaging with C-Arm CT Systems
    Rausch, Johannes
    Maier, Andreas
    Fahrig, Rebecca
    Choi, Jang-Hwan
    Hinshaw, Waldo
    Schebesch, Frank
    Haase, Sven
    Wasza, Jakob
    Hornegger, Joachim
    Riess, Christian
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2016, 2016
  • [34] Effectuality study of a 3D motion correction algorithm in C-arm CTs of severely impaired image quality during transarterial chemoembolization
    Becker, Lena S.
    Dewald, Cornelia L. A.
    von Falck, Christian
    Werncke, Thomas
    Maschke, Sabine K.
    Kloeckner, Roman
    Wacker, Frank K.
    Meyer, Bernhard C.
    Hinrichs, Jan B.
    CANCER IMAGING, 2022, 22 (01)
  • [35] Effectuality study of a 3D motion correction algorithm in C-arm CTs of severely impaired image quality during transarterial chemoembolization
    Lena S. Becker
    Cornelia L. A. Dewald
    Christian von Falck
    Thomas Werncke
    Sabine K. Maschke
    Roman Kloeckner
    Frank K. Wacker
    Bernhard C. Meyer
    Jan B. Hinrichs
    Cancer Imaging, 22
  • [36] Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities
    Fahrig, R
    Holdsworth, DW
    MEDICAL PHYSICS, 2000, 27 (01) : 30 - 38
  • [37] Motion Reduction for C-Arm Computed Tomography of the Pulmonary Arteries: Image Quality of a Motion Correction Algorithm in Patients with Chronic Thromboembolic Hypertension During Balloon Pulmonary Angioplasty
    Maschke, Sabine
    Werncke, Thomas
    Becker, Lena Sophie
    Renne, Julius
    Dewald, Cornelia Lieselotte Angelika
    Olsson, Karen M.
    Hoeper, Marius M.
    Wacker, Frank K.
    Meyer, Bernhard C.
    Hinrichs, Jan B.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (09): : 1074 - 1080
  • [38] 3D Segmentation and Rigid Registration for Minimizing Breathing Motion Effects in Liver CT Perfusion
    Jensen, N.
    Lock, M.
    Kozak, R.
    Chen, J.
    Lee, T.
    Wong, E.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [39] Super-global distortion correction for a rotational C-arm x-ray image intensifier
    Liu, RR
    Rudin, S
    Bednarek, DR
    MEDICAL PHYSICS, 1999, 26 (09) : 1802 - 1810
  • [40] Super-global distortion correction for a rotational C-arm x-ray image intensifier
    Toshiba Stroke Research Center, Departments of Physics and Radiology, State University of New York at Buffalo, Buffalo, NY 14214, United States
    不详
    Med. Phys., 9 (1802-1810):