A review of the image segmentation and registration methods in liver motion correction in C-arm perfusion imaging

被引:0
|
作者
Haseljic, Hana [1 ]
Frysch, Robert [1 ]
Kulvait, Vojtech [1 ]
Rose, Georg [1 ]
机构
[1] Otto von Guericke Univ, Inst Med Engn & Res Campus STIMUIATE, Univ Pl 2, D-39106 Magdeburg, Germany
关键词
C-arm; perfusion imaging; motion correction; image registration;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The C-arm perfusion imaging is not yet the standard part for liver cancer diagnosis and intraoperative measurements. The number of multiple rotations of C-arm depends on the total angle range resulting in large number of projections. Usually most of the liver disease features can be visible on CT images. However, the breathing and other liver surrounding organs motion during the acquisition can cause artifacts or missing important data on reconstructed CT images. In C-arm systems this is the consequence of the slow rotation. This paper gives an overview of existing motion correction algorithms used in medical imaging. These algorithms are based on image segmentation and registration.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [11] Evaluating the Feasibility of C-arm CT for Brain Perfusion Imaging: An in vitro Study
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [12] C-Arm Perfusion Imaging with a Fast Penalized Maximum-Likelihood Approach
    Frysch, Robert
    Pfeiffer, Tim
    Bannasch, Sebastian
    Serowy, Steffen
    Gugel, Sebastian
    Skalej, Martin
    Rose, Georg
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [13] Correction of Patient Motion in C-Arm Cone-Beam CT Using 3D-2D Registration
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3792 - 3793
  • [14] Clinical Applications of Quantitative Perfusion Imaging with a C-Arm Flat-Panel Detector-A Systematic Review
    Al-Kaylani, Abdallah H. A. Zaid
    Schuurmann, Richte C. L.
    Maathuis, Wouter D.
    Slart, Riemer H. J. A.
    De Vries, Jean-Paul P. M.
    Bokkers, Reinoud P. H.
    DIAGNOSTICS, 2023, 13 (01)
  • [15] First pass cable artefact correction for cardiac C-arm CT imaging
    Haase, C.
    Schaefer, D.
    Kim, M.
    Chen, S. J.
    Carroll, J. D.
    Eshuis, P.
    Doessel, O.
    Grass, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3861 - 3875
  • [16] A morphological enhancement technique for fiducial marker segmentation from C-arm fluoroscopy image
    Wu, CC
    Tseng, CS
    Hou, SM
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1352 - 1352
  • [17] Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery
    Chang, Chih-Ju
    Lin, Geng-Li
    Tse, Alex
    Chu, Hong-Yu
    Tseng, Ching-Shiow
    APPLIED BIONICS AND BIOMECHANICS, 2015, 2015
  • [18] Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP
    Pruemmer, M.
    Wigstroem, L.
    Hornegger, J.
    Boese, J.
    Lauritsch, G.
    Strobel, N.
    Fahrig, R.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2620 - 2628
  • [19] Geometric correction and error analysis of C-arm X-ray image distortion
    Robotics Institute, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
    不详
    Gaojishu Tongxin, 2006, 6 (600-605):
  • [20] Improvement in C-arm acquired DSA image quality via combined effect of inverse consistent motion correction and nonlinear normalization
    Kumar, Dinesh
    Wei, Liyang
    Turlapati, Ram
    Suri, Jasjit S.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 876 - 879