Frailty, Physical Activity, and Mobility in Patients With Cardiac Implantable Electrical Devices

被引:29
|
作者
Kramer, Daniel B. [1 ,2 ,3 ]
Tsai, Timothy [1 ]
Natarajan, Poorna [2 ,3 ]
Tewksbury, Elise [2 ,3 ]
Mitchell, Susan L. [1 ,2 ]
Travison, Thomas G. [1 ,2 ]
机构
[1] Hebrew SeniorLife Inst Aging Res, Boston, MA USA
[2] Harvard Med Sch, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Div Cardiol, Dept Med, Richard & Susan Smith Ctr Outcomes Res Cardiol, Boston, MA 02215 USA
来源
基金
美国国家卫生研究院;
关键词
aging; defibrillation; pacemaker; physical exercise; LOWER-EXTREMITY FUNCTION; GAIT SPEED; OLDER-ADULTS; DEFIBRILLATOR IMPLANTATION; ELDERLY-PATIENTS; GO TEST; DISABILITY; MORTALITY; OUTCOMES; PREDICTION;
D O I
10.1161/JAHA.116.004659
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aimed to demonstrate the feasibility of measuring frailty in patients with cardiac implantable electrical devices while validating the physiologic significance of device-detected physical activity by evaluating its association with frailty and mobility. Methods and Results: Outpatients with cardiac implantable electrical devices compatible with physical activity analysis with at least 7 days of data were eligible. Office testing included frailty status (Study of Osteoporotic Fractures instrument), gait speed (m/s), mobility according to the Timed Up and Go (TUG) test (seconds), and daily physical activity (h/d) as measured by cardiac implantable electrical device. Among 219 patients, Study of Osteoporotic Fractures testing found 39.7% to be robust, 47.5% prefrail, and 12.8% frail. The mean gait speed for the cohort was 0.8 +/- 0.3 m/s, mean TUG time was 10.9 +/- 4.4 seconds, and mean activity was 2.8 +/- 1.9 h/d. Frail patients were markedly more likely to have gait speeds < 0.8 m/s (OR 6.25, 95% CI 1.79-33.3). In unadjusted analyses each 1-hour increase in mean daily activity was associated with a 46% reduction of frail phenotype (OR 0.54, 95% CI 0.40-0.74) versus robust and with a 27% reduction in the odds of having the prefrail phenotype (OR 0.73, 95% CI 0.62-0.86). After adjustment this association per hour of activity persisted, with an adjusted OR for frailty of 0.71 (95% CI 0.51-0.99) and adjusted OR for prefrailty of 0.81 (95% CI 0.67-0.99). Conclusions: Frailty and mobility limitation are common among cardiac implantable electrical device patients and are correlated to device-detected physical activity.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] MRI for Patients with Cardiac Implantable Electrical Devices
    Chow, Grant V.
    Nazarian, Saman
    CARDIOLOGY CLINICS, 2014, 32 (02) : 299 - +
  • [2] Risk of cardioversion for patients with cardiac implantable electrical devices
    Yoneda, Zachary T.
    Crossley, George H.
    HEART RHYTHM, 2023, 20 (09) : 1236 - 1237
  • [3] Reproducibility of CMR in Patients With Cardiac Implantable Electrical Devices
    Ostovaneh, Mohammad R.
    Ward, Caroline
    Ambale-Venkatesh, Bharath
    Chamera, Elzbieta
    Kato, Yoko
    Bolli, Roberto
    Mitrani, Raul
    Perin, Emerson C.
    Henry, Timothy D.
    Hare, Joshua M.
    Moye, Lem
    Nazarian, Saman
    Lima, Joao A. C.
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (05) : 952 - 954
  • [5] Cardiac implantable electrical devices in women
    Elango, Kalaimani
    Curtis, Anne B.
    CLINICAL CARDIOLOGY, 2018, 41 (02) : 232 - 238
  • [6] The Role of Implantable Cardiac Electrical Devices in Patients with Myotonic Dystrophy
    Curtis, Anne B.
    Dalal, Kinan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (12) : 1376 - 1377
  • [7] Reproducibility of CMR in Patients With Cardiac Implantable Electrical Devices REPLY
    Ghonim, Sarah
    Babu-Narayan, Sonya V.
    JACC-CARDIOVASCULAR IMAGING, 2022, 15 (05) : 955 - 956
  • [8] Infections of cardiac implantable electrical devices
    Billick, Maxime J.
    Bogler, Orly
    Gold, Wayne L.
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2024, 196 (12) : E415 - E415
  • [9] The Use of Electrocardiogram Smartwatches in Patients with Cardiac Implantable Electrical Devices
    Strik, Marc
    Ploux, Sylvain
    van der Zande, Joske
    Velraeds, Anouk
    Fontagne, Leslie
    Haissaguerre, Michel
    Bordachar, Pierre
    SENSORS, 2024, 24 (02)
  • [10] Future of implantable electrical cardiac devices
    Daubert, Jean-Claude
    Behaghel, Albin
    Leclercq, Christophe
    Mabo, Philippe
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2014, 198 (03): : 473 - 487