A neutron tomography facility at a low power research reactor

被引:26
|
作者
Koerner, S
Schillinger, B
Vontobel, P
Rauch, H
机构
[1] Atominst Osterreich Univ, A-1020 Vienna, Austria
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Tech Univ Munich, Fak Phys, D-85747 Garching, Germany
基金
欧盟地平线“2020”;
关键词
neutron radiography; neutron tomography; CCD-camera neutron radiography detector; digital image processing; white spot filter; position sensitive imaging device;
D O I
10.1016/S0168-9002(01)00917-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutron radiography (NR) provides a very efficient tool in the field of non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two-dimensional (2D) imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. Contrary to Xrays, neutrons can be attenuated by some light materials, as for example, hydrogen and boron, but penetrate many heavy materials. Therefore, NR can yield important information not obtainable by more traditional methods. Nevertheless, there are many aspects of structure, both quantitative and qualitative, that are not accessible from 2D transmission images. Hence, there is an interest in three-dimensional neutron imaging. At the 250 kW TRIGA Mark II reactor of the Atominstitut in Austria a neutron tomography facility has been installed. The neutron flux at this beam position is 1.3 x 10(5) neutrons/cm(2)s and the beam diameter is 8 cm. For a 3D tomographic reconstruction of the sample interior, transmission images of the object taken from different view angles are required. Therefore, a rotary table driven by a step motor connected to a computerized motion control system has been installed at the sample position. In parallel a suitable electronic imaging device based on a neutron sensitive scintillator screen and a CCD-camera has been designed. It can be controlled by a computer in order to synchronize the software of the detector and of the rotary table with the aim of an automation of measurements. Reasonable exposure times can get as low as 20 s per image. This means that a complete tomography of a sample can be performed within one working day. Calculation of the 3D voxel array is made by using the filtered backprojection algorithm. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [41] Quasielastic neutron scattering facility at Dhruva reactor
    Mukhopadhyay, R
    Mitra, S
    Paranjpe, SK
    Dasannacharya, BA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 474 (01): : 55 - 66
  • [42] The design and optimization of a radiation shield for the Tehran Research Reactor's neutron diffraction facility
    Menarebazari, Z. Aslani
    Jafari, H.
    Gholamzadeh, Z.
    Bavarnegin, E.
    Fakhr, F. Siavoshi
    PROGRESS IN NUCLEAR ENERGY, 2022, 148
  • [43] Characterization of the fast neutron irradiation facility of the Portuguese Research Reactor after core conversion
    Marques, J. G.
    Sousa, M.
    Santos, J. P.
    Fernandes, A. C.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (08) : 1128 - 1130
  • [44] Characterization and quantification of an in-core neutron irradiation facility at a TRIGA II research reactor
    Aghara, Sukesh
    Charlton, William
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 248 (01): : 181 - 190
  • [45] A computational- experimental model of reactor kinetic for investigating the linearity response of in-core neutron detectors of a low power research reactor
    Asgari, Afrouz
    Hosseini, Seyed Abolfazl
    Dastjerdi, Mohammad Hossein Choopan
    Mokhtari, Javad
    NUCLEAR ENGINEERING AND DESIGN, 2024, 424
  • [46] A novel reactor concept for boron neutron capture therapy: Annular low-low power reactor (ALLPR)
    Petrovic, B
    Levine, SH
    RRFM'98: 2ND INTERNATIONAL TOPICAL MEETING ON RESEARCH REACTOR FUEL MANAGEMENT: INVITED AND CONTRIBUTED PAPERS - ORAL AND POSTER PRESENTATIONS, 1998, : 21 - 25
  • [47] Neutron shielding calculations for neutron imaging facility at the Maamora Triga reactor
    Ouardi, Afaf
    APPLIED RADIATION AND ISOTOPES, 2021, 176
  • [48] Digitized neutron imaging with high spatial resolution at a low power research reactor: Applications to steel and rock samples
    Zawisky, M.
    Hameed, F.
    Dyrnjaja, E.
    Springer, J.
    Rohatsch, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (15): : 2446 - 2450
  • [49] Investigation of BeO as a reflector for the low power research reactor
    Dawahra, S.
    Khattab, K.
    Saba, G.
    PROGRESS IN NUCLEAR ENERGY, 2015, 81 : 1 - 5
  • [50] Research-reactor neutron fields for calibrating in-reactor detectors in nuclear power plants
    V. D. Sevast’yanov
    S. A. Nikolaev
    I. E. Somov
    V. F. Shikalov
    M. G. Mittel’man
    Atomic Energy, 2006, 100 : 96 - 103