A neutron tomography facility at a low power research reactor

被引:26
|
作者
Koerner, S
Schillinger, B
Vontobel, P
Rauch, H
机构
[1] Atominst Osterreich Univ, A-1020 Vienna, Austria
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Tech Univ Munich, Fak Phys, D-85747 Garching, Germany
基金
欧盟地平线“2020”;
关键词
neutron radiography; neutron tomography; CCD-camera neutron radiography detector; digital image processing; white spot filter; position sensitive imaging device;
D O I
10.1016/S0168-9002(01)00917-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutron radiography (NR) provides a very efficient tool in the field of non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two-dimensional (2D) imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. Contrary to Xrays, neutrons can be attenuated by some light materials, as for example, hydrogen and boron, but penetrate many heavy materials. Therefore, NR can yield important information not obtainable by more traditional methods. Nevertheless, there are many aspects of structure, both quantitative and qualitative, that are not accessible from 2D transmission images. Hence, there is an interest in three-dimensional neutron imaging. At the 250 kW TRIGA Mark II reactor of the Atominstitut in Austria a neutron tomography facility has been installed. The neutron flux at this beam position is 1.3 x 10(5) neutrons/cm(2)s and the beam diameter is 8 cm. For a 3D tomographic reconstruction of the sample interior, transmission images of the object taken from different view angles are required. Therefore, a rotary table driven by a step motor connected to a computerized motion control system has been installed at the sample position. In parallel a suitable electronic imaging device based on a neutron sensitive scintillator screen and a CCD-camera has been designed. It can be controlled by a computer in order to synchronize the software of the detector and of the rotary table with the aim of an automation of measurements. Reasonable exposure times can get as low as 20 s per image. This means that a complete tomography of a sample can be performed within one working day. Calculation of the 3D voxel array is made by using the filtered backprojection algorithm. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [21] The cold neutron PGAA-NIPS facility at the Budapest research reactor
    Belgya, T
    Révay, Z
    Ember, PP
    Weil, J
    Molnár, GL
    Qaim, SM
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2003, : 562 - 568
  • [22] The upgrading of the cyclic neutron activation analysis facility at the Dalat research reactor
    Van Doanh Ho
    Manh Dung Ho
    Thanh Viet Ha
    Quang Thien Tran
    Dong Vu Cao
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 315 (03) : 703 - 709
  • [23] Construction of the neutron beam facility at Australia's OPAL research reactor
    Kennedy, Shane J.
    PHYSICA B-CONDENSED MATTER, 2006, 385-86 : 949 - 954
  • [24] High-Resolution Powder Diffractometer Facility (HRPDF) for Low and Medium Power Research Reactor
    AbuSaleem, Khalifeh
    JORDAN JOURNAL OF PHYSICS, 2023, 16 (04): : 423 - 434
  • [25] A Simple Setup for Neutron Tomography at the Portuguese Nuclear Research Reactor
    Stanojev Pereira, M. A.
    Marques, J. G.
    Pugliesi, R.
    BRAZILIAN JOURNAL OF PHYSICS, 2012, 42 (5-6) : 360 - 364
  • [26] NEUTRON TOMOGRAPHY INVESTIGATIONS AT MISSOURI-UNIVERSITY RESEARCH REACTOR
    SCHLAPPER, GA
    BRUGGER, RM
    SEYDEL, JE
    LARSEN, GN
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 26 : 39 - 39
  • [27] A Simple Setup for Neutron Tomography at the Portuguese Nuclear Research Reactor
    M. A. Stanojev Pereira
    J. G. Marques
    R. Pugliesi
    Brazilian Journal of Physics, 2012, 42 : 360 - 364
  • [28] Development of a neutron tomography system using a low flux reactor
    Hungler, P. C.
    Bennett, L. G. I.
    Lewis, W. J.
    Bevan, G. A.
    Gabov, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 651 (01): : 81 - 85
  • [29] A Monte Carlo evaluation of neutron images quality in a research reactor based neutron radiography facility
    Jafari, H.
    Dastjerdi, M. H. Choopan
    Moghadam, S. Rajabi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 976
  • [30] A LOW-COST NEUTRON-CAPTURE PROMPT GAMMA-RAY ANALYSIS FACILITY AT A RESEARCH REACTOR
    JONES, JD
    LUDINGTON, MA
    RIGOT, WL
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1982, 72 (1-2): : 287 - 294