A neutron tomography facility at a low power research reactor

被引:26
|
作者
Koerner, S
Schillinger, B
Vontobel, P
Rauch, H
机构
[1] Atominst Osterreich Univ, A-1020 Vienna, Austria
[2] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[3] Tech Univ Munich, Fak Phys, D-85747 Garching, Germany
基金
欧盟地平线“2020”;
关键词
neutron radiography; neutron tomography; CCD-camera neutron radiography detector; digital image processing; white spot filter; position sensitive imaging device;
D O I
10.1016/S0168-9002(01)00917-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutron radiography (NR) provides a very efficient tool in the field of non-destructive testing as well as for many applications in fundamental research. A neutron beam penetrating a specimen is attenuated by the sample material and detected by a two-dimensional (2D) imaging device. The image contains information about materials and structure inside the sample because neutrons are attenuated according to the basic law of radiation attenuation. Contrary to Xrays, neutrons can be attenuated by some light materials, as for example, hydrogen and boron, but penetrate many heavy materials. Therefore, NR can yield important information not obtainable by more traditional methods. Nevertheless, there are many aspects of structure, both quantitative and qualitative, that are not accessible from 2D transmission images. Hence, there is an interest in three-dimensional neutron imaging. At the 250 kW TRIGA Mark II reactor of the Atominstitut in Austria a neutron tomography facility has been installed. The neutron flux at this beam position is 1.3 x 10(5) neutrons/cm(2)s and the beam diameter is 8 cm. For a 3D tomographic reconstruction of the sample interior, transmission images of the object taken from different view angles are required. Therefore, a rotary table driven by a step motor connected to a computerized motion control system has been installed at the sample position. In parallel a suitable electronic imaging device based on a neutron sensitive scintillator screen and a CCD-camera has been designed. It can be controlled by a computer in order to synchronize the software of the detector and of the rotary table with the aim of an automation of measurements. Reasonable exposure times can get as low as 20 s per image. This means that a complete tomography of a sample can be performed within one working day. Calculation of the 3D voxel array is made by using the filtered backprojection algorithm. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [31] Monochromatic neutron tomography using 1-D PSD detector at low flux research reactor
    Ashari, N. Abidin
    Saleh, J. Mohamad
    Abdullah, M. Zaid
    Mohamed, A. Aziz
    Azman, A.
    Jamro, R.
    NEUTRON AND X-RAY SCATTERING IN MATERIALS SCIENCE AND BIOLOGY, 2008, 989 : 194 - +
  • [32] Neutron dosimetry at the reactor facility VENUS
    Deboodt, P
    Vermeersch, F
    Vanhavere, F
    Minsart, G
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 187 - 192
  • [33] A Neutron Flux Monitor for a Reactor Neutron Beam Facility
    Kandlakunta, Praneeth
    Mulligan, Padhraic
    Turkoglu, Danyal
    Cao, Lei
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1991 - 1995
  • [34] REACTOR-BASED PROMPT GAMMA-NEUTRON ACTIVATION SETUP USING A LOW-POWER RESEARCH REACTOR
    CHUNG, C
    YUAN, LJ
    NUCLEAR TECHNOLOGY, 1995, 109 (02) : 226 - 235
  • [35] Characterisation of the epithermal neutron irradiation facility at the Portuguese research reactor using MCNP
    Beasley, D. G.
    Fernandes, A. C.
    Santos, J. P.
    Ramos, A. R.
    Marques, J. G.
    King, A.
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 186 - 192
  • [36] RADIATION PROTECTION CONSIDERATIONS FOR INSERTION OF COLD NEUTRON FACILITY AT NBS RESEARCH REACTOR
    BROWN, DR
    WANG, JC
    HEALTH PHYSICS, 1987, 52 : S31 - S31
  • [37] Design study of neutron beam facility around TRIGA research reactor core
    Yasmeen, Rashida
    Mahmood, Mohammad Sayem
    ANNALS OF NUCLEAR ENERGY, 2016, 91 : 203 - 205
  • [38] Calculations and measurements of neutron fields in a facility for big sample neutron activation analysis at the research reactor at Delft
    Bos, AJJ
    Hoogenboom, JE
    PROCEEDINGS OF THE 1996 TOPICAL MEETING RADIATION PROTECTION & SHIELDING, VOLS 1 AND 2, 1996, 1-2 : 584 - 590
  • [39] Fast neutron radiography and tomography at a 10 MW research reactor beamline
    Zboray, R.
    Adams, R.
    Kis, Z.
    APPLIED RADIATION AND ISOTOPES, 2017, 119 : 43 - 50
  • [40] Medical irradiation facility based on a fluid fuel reactor with low power
    Litjaev, VM
    Pivovarov, VA
    Soloviev, NA
    Sysoev, AS
    Ulyanenko, SE
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A396 - A399