Monte Carlo study of a mosfet detector response applied to x-ray Microbeam Radiation Therapy

被引:0
|
作者
De Felici, M [1 ]
Felici, R [1 ]
Del Rio, MS [1 ]
Dilmanian, A [1 ]
Ferreo, C [1 ]
机构
[1] European Synchrotron Radiat Facil, INFM, OGG, F-38043 Grenoble, France
关键词
D O I
10.1142/9789812702708_0055
中图分类号
O59 [应用物理学];
学科分类号
摘要
EGS4 Monte Carlo calculations of the dose deposited by array of microbeams, used for the Microbeam Radiation Therapy technique, are presented. The sensitivity of the results to the experimental parameters (incident beam energy, beam array dimensions and spacing) has been assessed. The effects of the photon beam polarization and energy cutoff have also been investigated. The response of a Silicon MOSFET detector of micrometric dimensions, placed inside a phantom made of two homogeneous media (water and PMMA), has been simulated.
引用
收藏
页码:366 / 373
页数:8
相关论文
共 50 条
  • [1] Dose distribution from x-ray microbeam arrays applied to radiation therapy: An EGS4 Monte Carlo study
    De Felici, M
    Felici, R
    del Rio, MS
    Ferrero, C
    Bacarian, T
    Dilmanian, FA
    MEDICAL PHYSICS, 2005, 32 (08) : 2455 - 2463
  • [2] Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Fernandez-Varea, J. M.
    Bravin, A.
    Prezado, Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15): : 4375 - 4388
  • [3] Monte Carlo Study of a Compact Distributed X-Ray Source Microbeam Radiation Therapy Research Irradiator
    Schreiber, E.
    Chang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3899 - 3899
  • [4] Monte Carlo modelling of a silicon strip detector for microbeam radiation therapy
    Cullen, Ashley
    Lerch, Michael
    Petasecca, Marco
    Rosenfeld, Anatoly
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1646 - 1649
  • [5] Monte Carlo simulation of stereotactic microbeam radiation therapy: evaluation of the usage of a linear accelerator as the x-ray source
    Gokeri, Gurdal
    Kocar, Cemil
    Tombakoglu, Mehmet
    Cecen, Yigit
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13): : 4621 - 4642
  • [6] Monte Carlo simulation for x-ray detector
    Cai, Houzhi
    Liu, Jinyuan
    Peng, Xiang
    Niu, Lihong
    Peng, Wenda
    Long, Jinghua
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN IMAGING DETECTORS AND APPLICATIONS, 2011, 8194
  • [7] MOSFET dosimetry of an X-ray microbeam
    Rosenfeld, A.B.
    Kaplan, G.I.
    Kron, T.
    Allen, B.J.
    Dilmanian, A.
    Orion, I.
    Ren, B.
    Lerch, M.L.F.
    Holmes-Siedle, A.
    IEEE Transactions on Nuclear Science, 1999, 46 (6 I): : 1774 - 1780
  • [8] X-ray microbeam radiation therapy calculations, including polarisation effects, with the Monte Carlo code EGS5
    Hugtenburg, Richard P.
    Adegunloye, A. S.
    Bradley, David A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 221 - 224
  • [9] Monte Carlo study of x-ray cross-talk in a variable resolution x-ray detector
    Melnyk, R
    DiBianca, FA
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 694 - 701
  • [10] Technical advances in x-ray microbeam radiation therapy
    Bartzsch, Stefan
    Corde, Stephanie
    Crosbie, Jeffrey C.
    Day, Liam
    Donzelli, Mattia
    Krisch, Michael
    Lerch, Michael
    Pellicioli, Paolo
    Smyth, Lloyd M. L.
    Tehei, Moeava
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (02):