摘要
EGS4 Monte Carlo calculations of the dose deposited by array of microbeams, used for the Microbeam Radiation Therapy technique, are presented. The sensitivity of the results to the experimental parameters (incident beam energy, beam array dimensions and spacing) has been assessed. The effects of the photon beam polarization and energy cutoff have also been investigated. The response of a Silicon MOSFET detector of micrometric dimensions, placed inside a phantom made of two homogeneous media (water and PMMA), has been simulated.
引用
收藏
页码:366 / 373
页数:8
相关论文
共 50 条
  • [31] Monte Carlo study of x-ray beams produced by an on-board imager for image-guided radiation therapy
    Ding, G.
    Duggan, D.
    Coffey, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2473 - 2473
  • [32] Dose calculation algorithm for a compact x-ray source in Microbeam Radiation Therapy
    Ahmed, M.
    Wilkens, J. J.
    Bartzsch, S.
    Combs, S. E.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S751 - S752
  • [33] MONTE-CARLO STUDY OF A HARD X-RAY CONCENTRATOR
    PASQUALINI, G
    DECHIARA, P
    FRONTERA, F
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-GEOPHYSICS AND SPACE PHYSICS, 1990, 13 (02): : 445 - 451
  • [34] Computed tomography x-ray characterization: A Monte Carlo study
    Campos, Luciana Tourinho
    de Jesus, Fillipe Machado
    de Souza Goncalves, Elicardo Alves
    Goncalves Magalhaes, Luis Alexandre
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167 (167)
  • [35] The X-ray Radiation Response of CdZnTe Crystal Nuclear Detector
    Dai, X. Y.
    Meng, H.
    Zhang, Y. L.
    Tao, J.
    Xu, R.
    Zhang, J. J.
    Huang, J.
    Wang, L.
    Tang, K.
    Min, J. H.
    Wang, L. J.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY AND MANAGEMENT SCIENCE (ITMS 2015), 2015, 34 : 1296 - 1299
  • [36] Monte Carlo simulations for XIDer, a novel digital integration X-ray detector for the next generation of synchrotron radiation sources
    Collonge, M.
    Busca, P.
    Fajardo, P.
    Williams, M.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (01)
  • [37] Characteristics of amorphous selenium detector for monoenergetic X-ray determined by Monte Carlo simulation
    Yun, EJ
    Lee, HW
    Lee, JS
    Nam, SH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 444 - 445
  • [38] Characterization of New Structure for Silicon Carbide X-Ray Detector by Method Monte Carlo
    Stankovic, S. J.
    Ilic, R. D.
    Jankovic, K. S.
    Vasic-Milovanovic, A.
    Loncar, B.
    ACTA PHYSICA POLONICA A, 2011, 120 (02) : 252 - 255
  • [39] Surface dose reduction from bone interface in kilovoltage X-ray radiation therapy: a Monte Carlo study of photon spectra
    Chow, James C. L.
    Owrangi, Amir M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 215 - 222
  • [40] Monte Carlo simulations in X-ray imaging
    Giersch, Juergen
    Durst, Juergen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 300 - 305