Monte Carlo study of a mosfet detector response applied to x-ray Microbeam Radiation Therapy

被引:0
|
作者
De Felici, M [1 ]
Felici, R [1 ]
Del Rio, MS [1 ]
Dilmanian, A [1 ]
Ferreo, C [1 ]
机构
[1] European Synchrotron Radiat Facil, INFM, OGG, F-38043 Grenoble, France
关键词
D O I
10.1142/9789812702708_0055
中图分类号
O59 [应用物理学];
学科分类号
摘要
EGS4 Monte Carlo calculations of the dose deposited by array of microbeams, used for the Microbeam Radiation Therapy technique, are presented. The sensitivity of the results to the experimental parameters (incident beam energy, beam array dimensions and spacing) has been assessed. The effects of the photon beam polarization and energy cutoff have also been investigated. The response of a Silicon MOSFET detector of micrometric dimensions, placed inside a phantom made of two homogeneous media (water and PMMA), has been simulated.
引用
收藏
页码:366 / 373
页数:8
相关论文
共 50 条
  • [21] Brain motion induced artefacts in microbeam radiation therapy: a Monte Carlo study
    Donzelli, M.
    Braeuer-Krisch, E.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S425 - S425
  • [22] A theoretical study to focus a polychromatic synchrotron X-ray beam for microbeam radiation therapy
    Iskandar, Kyrollos
    Crosbie, Jeffrey C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 997
  • [23] MONTE CARLO DOSIMETRY FOR THE CLINICAL TRIALS IN MICROBEAM RADIATION THERAPY
    Martinez-Rovira, I.
    Alonso, Y. Prezado
    Sempau, J.
    Fernandez-Varea, J. M.
    Bravin, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S71 - S72
  • [24] Monte Carlo dose enhancement studies in microbeam radiation therapy
    Martinez-Rovira, I.
    Prezado, Y.
    MEDICAL PHYSICS, 2011, 38 (07) : 4430 - 4439
  • [25] Surface Dose Reduction from Bone Interface in Superficial X-Ray Radiation Therapy: A Monte Carlo Study
    Chow, J.
    Owrangi, A.
    Grigorov, G.
    MEDICAL PHYSICS, 2011, 38 (06) : 3649 - +
  • [26] Optimization of a compact x-ray source for clinical microbeam radiation therapy
    Winter, J.
    Wilkens, J. J.
    Combs, S. E.
    Bartzsch, S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S264 - S265
  • [27] Improved spatial resolution by MOSFET dosimetry of an x-ray microbeam
    Kaplan, GI
    Rosenfeld, AB
    Allen, BJ
    Booth, JT
    Carolan, MG
    Holmes-Siedle, A
    MEDICAL PHYSICS, 2000, 27 (01) : 239 - 244
  • [28] Energy discrimination with an X-ray pixel detector - a Monte-Carlo simulation
    Pedersen, F
    Ronnqvist, C
    Fransson, K
    Gustafsson, L
    Kullander, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03): : 443 - 447
  • [29] X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy
    Fournier, Pauline
    Cornelius, Iwan
    Donzelli, Mattia
    Requardt, Herwig
    Nemoz, Christian
    Petasecca, Marco
    Brauer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1180 - 1190
  • [30] Dosimetric studies of microbeam radiation therapy (MRT) with Monte Carlo simulations
    Siegbahn, EA
    Bräuer-Krisch, E
    Stepanek, J
    Blattmann, H
    Laissue, JA
    Bravin, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 54 - 58