The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population

被引:76
|
作者
Seibert, J. Anthony [1 ]
Morin, Richard L. [2 ]
机构
[1] Univ Calif Davis, Dept Radiol, Sacramento, CA 95817 USA
[2] Mayo Clin Jacksonville, Dept Radiol, Jacksonville, FL 32224 USA
关键词
Digital radiography; Digital radiography exposure index; Pediatric radiography radiation dose; Radiography exposure index standard; ACR dose index registry;
D O I
10.1007/s00247-010-1954-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The exposure index is currently a method by which digital radiography manufacturers provide feedback to the technologist regarding the estimated exposure on the detector, as a surrogate for image signal-to-noise ratio and an indirect indication of digital image quality. Unfortunately, there are as many exposure index values and methods as there are manufacturers, and in an environment with multiple vendors and a need to share data across institutions and dose registry databases, the situation is complicated. Fortunately, a new exposure index of digital X-ray imaging systems has been implemented. Developed concurrently by the International Electrotechnical Commission and the American Association of Physicists in Medicine in cooperation with digital radiography system manufacturers, the index has been implemented as an international standard. As explained, the exposure index does not indicate patient dose but rather a linearly proportional estimate of the incident radiation exposure to the detector. However, the use of the standardized exposure index and its associated target exposure index and deviation index values will likely lead to improved technologist performance in terms of uniformity and use of optimized radiographic techniques, leading to safer care of children needing radiographic examinations. Radiologists will benefit from standardized terminology, and institutions and clinics will be able to compare exposure index values with others through a national dose index registry database now under development. The Alliance for Radiation Safety in Pediatric Imaging, in its role as a benefactor of and advocate for the pediatric patient, is using the Image Gently campaign to disseminate information regarding the exposure index standard for digital radiography so that these benefits can be achieved in a rapid and effective manner.
引用
收藏
页码:573 / 581
页数:9
相关论文
共 50 条
  • [31] Evaluation of the effects of subject thickness on the exposure index in digital radiography
    Takaki T.
    Takeda K.
    Murakami S.
    Ogawa H.
    Ogawa M.
    Sakamoto M.
    Radiological Physics and Technology, 2016, 9 (1) : 116 - 120
  • [32] Evaluation of digital radiography practice using exposure index tracking
    Scott, Alexander W.
    Zhou, Yifang
    Allahverdian, Janet
    Nute, Jessica L.
    Lee, Christina
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 343 - 355
  • [33] Effects of dose reduction on the detectability of standardized radiolucent lesions in digital panoramic radiography
    Dula, K
    Sanderink, G
    van der Stelt, PF
    Mini, R
    Buser, D
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (02): : 227 - 233
  • [34] Management of pediatric radiation dose using Fuji computed radiography
    D.W. MacCutcheon
    Pediatric Radiology, 2004, 34 : S201 - S206
  • [35] Management of pediatric radiation dose using Fuji computed radiography
    MacCutcheon, DW
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S201 - S206
  • [36] Management of pediatric radiation dose using Agfa computed radiography
    R. Schaetzing
    Pediatric Radiology, 2004, 34 : S207 - S214
  • [37] Management of pediatric radiation dose using Agfa computed radiography
    Schaetzing, R
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S207 - S214
  • [38] Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index
    Sinead E. Peters
    Patrick C. Brennan
    European Radiology, 2002, 12 : 2381 - 2387
  • [39] Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index
    Peters, SE
    Brennan, PC
    EUROPEAN RADIOLOGY, 2002, 12 (09) : 2381 - 2387
  • [40] Evaluation of automatic exposure control system chamber for the dose optimization when examining pelvic in digital radiography
    Kim, Sung-Chul
    Lee, Hae-Kag
    Lee, Yang-Sub
    Cho, Jae-Hwan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (03) : 321 - 330