The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population

被引:76
|
作者
Seibert, J. Anthony [1 ]
Morin, Richard L. [2 ]
机构
[1] Univ Calif Davis, Dept Radiol, Sacramento, CA 95817 USA
[2] Mayo Clin Jacksonville, Dept Radiol, Jacksonville, FL 32224 USA
关键词
Digital radiography; Digital radiography exposure index; Pediatric radiography radiation dose; Radiography exposure index standard; ACR dose index registry;
D O I
10.1007/s00247-010-1954-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The exposure index is currently a method by which digital radiography manufacturers provide feedback to the technologist regarding the estimated exposure on the detector, as a surrogate for image signal-to-noise ratio and an indirect indication of digital image quality. Unfortunately, there are as many exposure index values and methods as there are manufacturers, and in an environment with multiple vendors and a need to share data across institutions and dose registry databases, the situation is complicated. Fortunately, a new exposure index of digital X-ray imaging systems has been implemented. Developed concurrently by the International Electrotechnical Commission and the American Association of Physicists in Medicine in cooperation with digital radiography system manufacturers, the index has been implemented as an international standard. As explained, the exposure index does not indicate patient dose but rather a linearly proportional estimate of the incident radiation exposure to the detector. However, the use of the standardized exposure index and its associated target exposure index and deviation index values will likely lead to improved technologist performance in terms of uniformity and use of optimized radiographic techniques, leading to safer care of children needing radiographic examinations. Radiologists will benefit from standardized terminology, and institutions and clinics will be able to compare exposure index values with others through a national dose index registry database now under development. The Alliance for Radiation Safety in Pediatric Imaging, in its role as a benefactor of and advocate for the pediatric patient, is using the Image Gently campaign to disseminate information regarding the exposure index standard for digital radiography so that these benefits can be achieved in a rapid and effective manner.
引用
收藏
页码:573 / 581
页数:9
相关论文
共 50 条
  • [41] Protocol for reducing radiation exposure during pediatric thoracic radiography
    Souza, Carla Daruich De
    Freitas, Gustavo Rico
    Medeiros, Rogerio Fachel
    Ramalho, Ercilia
    Rodrigues, Sergio Chaves
    Rodrigues, Guilherme Oberto
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2022, 53 (03) : 437 - 443
  • [42] ASSESSMENT OF RADIATION-DOSE IN DIGITAL STORAGE PHOSPHOR RADIOGRAPHY
    BICK, U
    FIEBICH, M
    LENZEN, H
    WIESMANN, W
    PETERS, PE
    RADIOLOGE, 1991, 31 (01): : 8 - 10
  • [43] Assessment Of Radiation Dose In Digital Radiography System -A Review Article
    Pise, Kunal
    Tivaskar, Suhas
    Luharia, Anurag
    Dhande, Rajasbala
    Pathade, Aniket
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 69 - 75
  • [44] Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction
    Hufton, AP
    Doyle, SM
    Carty, HML
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842): : 186 - 199
  • [45] Optimization of dose and image quality in pediatrics chest digital radiography
    Deevband, Mohammad Reza
    Rahmani, Fereshteh
    Bardar, Meisam Ebrahimi
    Ghorbani, Mahdi
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 443 - 449
  • [46] Dose optimization and image quality measurement in digital abdominal radiography
    Karal, Omer
    Tokgoz, Nazime
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [47] Dose Optimization and Image Quality in Digital Radiography: A Review Article
    Barai, Juhi
    Tivaskar, Suhas
    Sable, Apeksha
    Luharia, Anurag
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 (03) : 1076 - 1080
  • [48] Radiation Exposure of Children in Pediatric Radiology Part 6: Conversion Factors for Reconstruction of Organ Dose in Abdominal Radiography
    Seidenbusch, M. C.
    Regulla, D.
    Schneider, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (10): : 945 - 961
  • [49] Radiation dose considerations in digital radiography with an anti-scatter grid: A study using adult and pediatric phantoms
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Kitao, Azusa
    Matsubara, Takashi
    Sugiura, Takumi
    Kobayashi, Tomohiro
    Kobayashi, Satoshi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):
  • [50] New image quality and dose reduction technique for pediatric digital radiography
    Feghali, Joelle A.
    Chambers, Greg
    Delepierre, Julie
    Chapeliere, Sophie
    Mannes, Ines
    Adamsbaum, Catherine
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (7-8) : 463 - 470