CCMod: a GATE module for Compton camera imaging simulation

被引:19
|
作者
Etxebeste, A. [1 ]
Dauvergne, D. [2 ]
Fontana, M. [3 ]
Letang, J. M. [1 ]
Llosa, G. [4 ]
Munoz, E. [4 ]
Oliver, J. F. [4 ]
Testa, E. [3 ]
Sarrut, D. [1 ]
机构
[1] Univ Lyon 1, Univ Lyon, CREATIS, CNRS UMR5220,Inserm U1044,INSA Lyon, Lyon, France
[2] Univ Grenoble Alpes, LPSC, CNRS IN2P3 UMR 5821, Grenoble, France
[3] Univ Claude Bernard Lyon 1, Univ Lyon, CNRS IN2P3 IP2I Lyon, F-69622 Villeurbanne, France
[4] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 05期
关键词
Monte Carlo; simulation; gamma imaging; Compton camera; ION-BEAM THERAPY; PERFORMANCE EVALUATION; RANGE VERIFICATION; PROTON-BEAMS; RESOLUTION; SYSTEM; MODEL; PET; OPTIMIZATION; SOFTWARE;
D O I
10.1088/1361-6560/ab6529
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compton cameras are gamma-ray imaging systems which have been proposed for a wide variety of applications such as medical imaging, nuclear decommissioning or homeland security. In the design and optimization of such a system Monte Carlo simulations play an essential role. In this work, we propose a generic module to perform Monte Carlo simulations and analyses of Compton Camera imaging which is included in the open-source GATE/Geant4 platform. Several digitization stages have been implemented within the module to mimic the performance of the most commonly employed detectors (e.g. monolithic blocks, pixelated scintillator crystals, strip detectors...). Time coincidence sorter and sequence coincidence reconstruction are also available in order to aim at providing modules to facilitate the comparison and reproduction of the data taken with different prototypes. All processing steps may be performed during the simulation (on-the-fly mode) or as a post-process of the output files (offline mode). The predictions of the module have been compared with experimental data in terms of energy spectra, angular resolution, efficiency and back-projection image reconstruction. Consistent results within a 3-sigma interval were obtained for the energy spectra except for low energies where small differences arise. The angular resolution measure for incident photons of 1275 keV was also in good agreement between both data sets with a value close to 13 degrees. Moreover, with the aim of demonstrating the versatility of such a tool the performance of two different Compton camera designs was evaluated and compared.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] CCMod: a GATE module for Compton camera imaging simulation (vol 65, 055004, 2020)
    Etxebeste, A.
    Dauvergne, D.
    Fontana, M.
    Letang, J. M.
    Llosa, G.
    Munoz, E.
    Oliver, J. F.
    Testa, E.
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12):
  • [2] The performance study of developed cost-effective Compton Camera based on Ce:GAGG scintillator using experimental measurements and CCMod of GATE simulation module
    Zarei, Hajar
    Nagao, Yuto
    Yamamoto, Kohei
    Itoh, Masatoshi
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Watabe, Hiroshi
    JOURNAL OF INSTRUMENTATION, 2022, 17 (10):
  • [3] Gate simulation of Compton Ar-Xe gamma-camera for radionuclide imaging in nuclear medicine
    Dubov, L. Yu
    Belyaev, V. N.
    Berdnikova, A. K.
    Bolozdynia, A. I.
    Akmalova, Yu A.
    Shtotsky, Yu V.
    1ST INTERNATIONAL SYMPOSIUM PHYSICS, ENGINEERING AND TECHNOLOGIES FOR BIO-MEDICINE, 2017, 784
  • [4] Compton Camera Imaging
    Ikeda, Shiro
    Odaka, Hirokazu
    Uemura, Makoto
    Takahashi, Tadayuki
    Watanabe, Shin
    Takeda, Shin'ichiro
    2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 674 - 677
  • [5] A Compton camera for multitracer imaging
    Yang, YF
    Gono, Y
    Motomura, S
    Enomoto, S
    Yano, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 656 - 661
  • [6] Simulation of Compton camera imaging with a specific purpose Monte Carlo code
    Earnhart, J
    Prettyman, T
    Lestone, J
    Gardner, R
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 673 - 680
  • [7] Monte Carlo simulation study on medical imaging of a multiply stacked Compton camera
    Kim, N. Y.
    Lee, C. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (02) : 1201 - 1204
  • [8] Simulation study of Compton camera imaging for human head phantom proton therapy
    Yao, Zhiyang
    Chen, Zhiqiang
    Xiao, Yongshun
    SECOND SYMPOSIUM ON NOVEL TECHNOLOGY OF X-RAY IMAGING, 2019, 11068
  • [9] Prospectus: Development of a Compton camera for medical imaging
    Harkness, L. J.
    Boston, A. J.
    Boston, H. C.
    Cresswell, J. R.
    Grint, A. N.
    Lazarus, I.
    Judson, D. S.
    Nolan, P. J.
    Oxley, D. C.
    Scraggs, D. P.
    Simpson, J.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 102 - 105
  • [10] A compton scatter camera design for in vivo medical imaging of radiopharmaceuticals: Results of simulation studies.
    Rohe, RC
    Valentine, JD
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 300 - 300