Refractive Error and Ocular Parameters: Comparison of Two SD-OCT Systems

被引:10
|
作者
Ostrin, Lisa A. [2 ]
Yuzuriha, Jill [1 ]
Wildsoet, Christine F. [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
SD-OCT; myopia; retina; choroid; refractive error; OPTICAL COHERENCE TOMOGRAPHY; HIGHLY MYOPIC EYES; MACULAR THICKNESS MEASUREMENTS; LAMINA-CRIBROSA THICKNESS; SPECTRAL-DOMAIN; CHOROIDAL THICKNESS; AXIAL LENGTH; DIABETIC-RETINOPATHY; STRATUS OCT; BEIJING EYE;
D O I
10.1097/OPX.0000000000000559
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Spectral domain optical coherence tomography (OCT) was used to examine the influence of refractive error (RE) on foveal retinal and choroidal thicknesses and scleral canal width (SCW). The performance of the Cirrus and Bioptigen spectral domain OCT instruments was compared in the same eyes. Methods. Both eyes of 40 healthy human subjects, aged 22 to 38 years, were dilated and imaged, with the Cirrus OCT, using 6-mm five-line rasters collapsed into one line, one centered on the fovea and one bisecting the optic nerve head. Seventy-two of the same eyes were imaged with the Bioptigen OCT, using 6-by 6-mm scans, one centered on the fovea and one on the optic nerve head. Subfoveal retinal and choroidal thicknesses and SCW were measured. Axial lengths (ALs) and REs were obtained using an IOLMaster and a Grand Seiko autorefractor, respectively. Results. Only right eyes were included in analyses. Spherical equivalent REs ranged from -12.18 to +8.12 diopters (mean [TSD], -3.44 [+/- 4.06] diopters), and ALs ranged from 20.56 to 29.17 mm (mean [+/- SD], 24.86 [+/- 1.91] mm). Myopia was associated with relatively thin choroids at the fovea (p < 0.05) but normal retinal thickness. Scleral canal width was significantly correlated with AL as measured with the Bioptigen OCT (p < 0.05). Retinal and choroidal thicknesses recorded with the Bioptigen OCT tended to be smaller than values obtained with the Cirrus OCT (mean difference, 5.63 and 24.76 Km, respectively), whereas the converse was true for the SCW (mean difference, 25.45 mu m). Conclusions. The finding that high myopes tend to have a thinner subfoveal choroid is consistent with previous studies. That high myopia was linked to enlarged scleral canals may help to explain the increased risk of glaucoma in myopia. Observed differences obtained with the Cirrus and Bioptigen instruments urge caution in comparing results collected with different instruments.
引用
收藏
页码:437 / 446
页数:10
相关论文
共 50 条
  • [1] ROLE OF SD-OCT IN OCULAR HYPERTENSION
    Anand, R.
    Solanki, Deepshikha
    Gupta, Sanchit
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (44): : 7604 - 7609
  • [2] Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT
    Akil, Handan
    Marion, Kenneth
    Dastiridou, Anna
    Jenkins, Dennis
    Kramer, Brendan
    Francis, Brian A.
    Chopra, Vikas
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (01) : 31 - 37
  • [3] Identification of anterior chamber angle parameters with a portable SD-OCT device compared to a non-portable SD-OCT
    Handan Akil
    Kenneth Marion
    Anna Dastiridou
    Dennis Jenkins
    Brendan Kramer
    Brian A. Francis
    Vikas Chopra
    International Ophthalmology, 2017, 37 : 31 - 37
  • [4] The comparison between subfoveal choroidal thickness measured with two different SD-OCT
    Maekawa, Yuki
    Suzuma, Kiyoshi
    Tsuiki, Eiko
    Kitaoka, Takashi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] The Normal Distribution of Disc Area on a Combined UWF-SLO plus SD-OCT device with Comparison to SD-OCT
    Speilburg, Ashley
    Salazar, Patricia
    Rozwat, Anne
    Turner, Lauren
    Chaglasian, Michael A.
    Sinai, Michael
    Speilburg, Ashley
    Salazar, Patricia
    Rozwat, Anne
    Turner, Lauren
    Chaglasian, Michael A.
    Sinai, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [6] Comparison of Ocular Ultrasound Versus SD-OCT for Imaging of the Posterior Vitreous Status in Patients With DME
    Pessoa, Bernardete
    Coelho, Joao
    Malheiro, Luisa
    Jos, Diana
    Pires, Saul
    Coelho, Constanca
    Figueira, Joao
    Meireles, Angelina
    Melo-Beirao, Joao
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2020, 51 (04): : S50 - S53
  • [7] Comparison of two SD-OCT models in determining the outer retina macula layers thickness
    Shahin, Alexander
    Khalil, Sabrina
    Richards, David
    Ayyala, Ramesh
    Tzekov, Radouil T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [8] Comparative Evaluation of Two SD-OCT Macular Parameters (GCC, GCL) and RNFL in Chiasmal Compression
    Santorini, Melissa
    De Moura, Thomas Ferreira
    Barraud, Sara
    Litre, Claude Fabien
    Brugniart, Catherine
    Denoyer, Alexandre
    Djerada, Zoubir
    Arndt, Carl
    EYE AND BRAIN, 2022, 14 : 35 - 48
  • [9] Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma
    Shoji, Takuhei
    Nagaoka, Yui
    Sato, Hiroki
    Chihara, Etsuo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (12) : 1843 - 1849
  • [10] Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma
    Takuhei Shoji
    Yui Nagaoka
    Hiroki Sato
    Etsuo Chihara
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1843 - 1849