Obtaining dual-energy computed tomography (CT) information from a single-energy CT image for quantitative imaging analysis of living subjects by using deep learning

被引:0
|
作者
Zhao, Wei [1 ]
Lv, Tianling [2 ]
Lee, Rena [3 ]
Chen, Yang [2 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Palo Alto, CA 94306 USA
[2] Southeast Univ, Dept Comp Sci & Engn, Nanjing 210096, Jiangsu, Peoples R China
[3] Ehwa Womens Univ, Dept Bioengn, Seoul, South Korea
关键词
Dual-energy computed tomography; Single-energy computed tomography; Deep learning; Convolutional neural network; Material decomposition; Virtual non-contrast; Iodine quantification; PRINCIPLES;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Computed tomographic (CT) is a fundamental imaging modality to generate cross-sectional views of internal anatomy in a living subject or interrogate material composition of an object, and it has been routinely used in clinical applications and nondestructive testing. In a standard CT image, pixels having the same Hounsfield Units (HU) can correspond to different materials, and it is therefore challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable to differentiate multiple materials, but the costly DECT scanners are not widely available as single-energy CT (SECT) scanners. Recent advancement in deep learning provides an enabling tool to map images between different modalities with incorporated prior knowledge. I [ere we develop a deep learning approach to perform DECT imaging by using the standard SECT data. The end point of the approach is a model capable of providing the high-energy CT image for a given input low-energy CT image. The feasibility of the deep learning-based DECT imaging method using a SECT data is demonstrated using contrast-enhanced DECT images and evaluated using clinical relevant indexes. This work opens new opportunities for numerous DECT clinical applications with a standard SECT data and may enable significantly simplified hardware design, scanning dose and image cost reduction for future DECT systems.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 50 条
  • [21] QUANTIFICATION OF CALCIUM IN SOLITARY PULMONARY NODULES USING SINGLE-ENERGY AND DUAL-ENERGY CT
    CANN, CE
    GAMSU, G
    BIRNBERG, FA
    WEBB, WR
    RADIOLOGY, 1982, 145 (02) : 493 - 496
  • [22] CT detection of myocardial blood volume deficits: Dual-energy CT compared with single-energy CT spectra
    Arnoldi, Elisabeth
    Lee, Yeong Shyan
    Ruzsics, Balazs
    Weininger, Markus
    Spears, J. Reid
    Rowley, Christopher P.
    Chiaramida, Salvatore A.
    Costello, Philip
    Reiser, Maximilian F.
    Schoepf, U. Joseph
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) : 421 - 429
  • [23] Real-time diagnosis of intracerebral hemorrhage by generating dual-energy CT from single-energy CT
    Jiang, Caiwen
    Wang, Tianyu
    Pan, Yongsheng
    Ding, Zhongxiang
    Shen, Dinggang
    MEDICAL IMAGE ANALYSIS, 2024, 95
  • [24] CT Detection of Myocardial Blood Volume Deficits: Dual-Energy CT Compared With Single-Energy CT Spectra
    Arnoldi, Elisabeth
    Ruzsics, Balazs
    Lee, Yeong Shyan
    Gebregziabher, Mulugeta
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Costello, Philip
    Schoepf, U. Joseph
    CIRCULATION, 2009, 120 (18) : S375 - S375
  • [25] Enabling Conventional Single-Energy CT Systems to Incorporate Dual -Energy CT Functionalities by Multimodality Deep Learning
    Li, B.
    Ye, S.
    Zhu, L.
    Chen, Y.
    Liu, L.
    Yu, L.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : S51 - S52
  • [26] Dual-Energy CT Imaging from Single Energy CT Sinograms By Exploiting the Cross-Energy Information with Transformer Networks
    Li, B.
    Ye, S.
    Zhu, L.
    Chen, Y.
    Liu, L.
    Yu, L.
    Xing, L.
    MEDICAL PHYSICS, 2024, 51 (09) : 6557 - 6557
  • [27] Single-energy CT predicts uric acid stones with accuracy comparable to dual-energy CT—prospective validation of a quantitative method
    Johan Jendeberg
    Per Thunberg
    Marcin Popiolek
    Mats Lidén
    European Radiology, 2021, 31 : 5980 - 5989
  • [28] Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance
    Zhu, Xiaowei
    McCullough, William P.
    Mecca, Patricia
    Servaes, Sabah
    Darge, Kassa
    PEDIATRIC RADIOLOGY, 2016, 46 (12) : 1671 - 1679
  • [29] Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance
    Xiaowei Zhu
    William P. McCullough
    Patricia Mecca
    Sabah Servaes
    Kassa Darge
    Pediatric Radiology, 2016, 46 : 1671 - 1679
  • [30] Comparison of metal artifact reduction using single-energy CT and dual-energy CT with various metallic implants in cadavers
    Barreto, Izabella
    Pepin, Eric
    Davis, Ivan
    Dean, Cooper
    Massini, Tara
    Rees, John
    Olguin, Catherine
    Quails, Nathan
    Correa, Nathalie
    Rill, Lynn
    Arreola, Manuel
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133