Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance

被引:23
|
作者
Zhu, Xiaowei [1 ,2 ]
McCullough, William P. [3 ]
Mecca, Patricia [1 ]
Servaes, Sabah [1 ,2 ]
Darge, Kassa [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch ofMedicine, Philadelphia, PA 19104 USA
[3] Univ Virginia Hlth Syst, Dept Radiol & Med Imaging, POB 800170, Charlottesville, VA 22908 USA
关键词
Children; Computed tomography; Dual-energy computed tomography; Radiation dose; LUNG PERFUSION; CHILDREN; QUALITY;
D O I
10.1007/s00247-016-3668-x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Dual-energy CT technology is available on scanners from several vendors and offers significant advantages over classic single-energy CT technology in multiple clinical applications. Many studies have detailed dual-energy CT applications in adults and several have evaluated the relative radiation dose performance of dual-energy CT in adult imaging. However, little has been published on dual-energy CT imaging in the pediatric population, and the relative dose performance of dual-energy CT imaging in the pediatric population is not well described. When evaluating dual-energy CT technology for implementation into a routine clinical pediatric imaging practice, the radiation dose implications must be considered, and when comparing relative CT dose performance, image quality must also be evaluated. Therefore the purpose of this study is to develop dual-energy CT scan protocols based on our optimized single-energy scan protocols and compare the dose. We scanned the head, chest and abdomen regions of pediatric-size anthropomorphic phantoms with contrast inserts, using our optimized single-energy clinical imaging protocols on a Siemens FlashA (R) CT scanner. We then scanned the phantoms in dual-energy mode using matching image-quality reference settings. The effective CT dose index volume (CTDIvol) of the scans was used as a surrogate for relative dose in comparing the single- and dual-energy scans. Additionally, we evaluated image quality using visual assessment and contrast-to-noise ratio. Dual-energy CT scans of the head and abdomen were dose-neutral for all three phantoms. Dual-energy CT scans of the chest showed a relative dose increase over the single-energy scan for 1- and 5-year-old child-based age-equivalent phantoms, ranging 11-20%. Quantitative analysis of image quality showed no statistically significant difference in image quality between the single-energy and dual-energy scans. There was no clinically significant difference in image quality by visual assessment. Dual-energy CT is dose-neutral in imaging the head and abdomen in children. It is not dose-neutral in chest imaging of very small children. With a better understanding of the dose consequences of converting single-energy protocols to dual-energy protocols we can begin to implement clinical dual-energy CT and utilize its unique capabilities in pediatric imaging.
引用
收藏
页码:1671 / 1679
页数:9
相关论文
共 50 条
  • [1] Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance
    Xiaowei Zhu
    William P. McCullough
    Patricia Mecca
    Sabah Servaes
    Kassa Darge
    Pediatric Radiology, 2016, 46 : 1671 - 1679
  • [2] Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT)
    Shayan, Ramin Ghasemi
    Oladghaffari, Maryam
    Sajjadian, Fakhrosadat
    Ghaziyani, Mona Fazel
    RADIOLOGY RESEARCH AND PRACTICE, 2020, 2020
  • [3] Twin beam dual-energy vs single-energy on a novel PET-dual energy CT: Phantom study and clinical validation.
    De Cecco, Carlo
    Burchett, Philip
    De Santis, Domenico
    Ravenel, James
    Schoepf, U.
    Gordon, Leonie
    Jackson, Logan
    Rieter, William
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [4] A deep learning approach for dual-energy CT imaging using a single-energy CT data
    Zhao, Wei
    Lv, Tianling
    Gao, Peng
    Shen, Liyue
    Dai, Xianjin
    Cheng, Kai
    Jia, Mengyu
    Chen, Yang
    Xing, Lei
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [5] CT detection of myocardial blood volume deficits: Dual-energy CT compared with single-energy CT spectra
    Arnoldi, Elisabeth
    Lee, Yeong Shyan
    Ruzsics, Balazs
    Weininger, Markus
    Spears, J. Reid
    Rowley, Christopher P.
    Chiaramida, Salvatore A.
    Costello, Philip
    Reiser, Maximilian F.
    Schoepf, U. Joseph
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) : 421 - 429
  • [6] Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
    Lundin, Margareta
    Liden, Mats
    Magnuson, Anders
    Mohammed, Ahmed Abdulilah
    Geijer, Hakan
    Andersson, Torbjorn
    Persson, Anders
    ACTA RADIOLOGICA, 2012, 53 (06) : 689 - 694
  • [7] CT Detection of Myocardial Blood Volume Deficits: Dual-Energy CT Compared With Single-Energy CT Spectra
    Arnoldi, Elisabeth
    Ruzsics, Balazs
    Lee, Yeong Shyan
    Gebregziabher, Mulugeta
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Costello, Philip
    Schoepf, U. Joseph
    CIRCULATION, 2009, 120 (18) : S375 - S375
  • [8] Renal lesion characterization: clinical utility of single-phase dual-energy CT compared to MRI and dual-phase single-energy CT
    Ali Pourvaziri
    Amirkasra Mojtahed
    Peter F. Hahn
    Michael S. Gee
    Avinash Kambadakone
    Dushyant V. Sahani
    European Radiology, 2023, 33 : 1318 - 1328
  • [9] Renal lesion characterization: clinical utility of single-phase dual-energy CT compared to MRI and dual-phase single-energy CT
    Pourvaziri, Ali
    Mojtahed, Amirkasra
    Hahn, Peter F.
    Gee, Michael S.
    Kambadakone, Avinash
    Sahani, Dushyant, V
    EUROPEAN RADIOLOGY, 2023, 33 (02) : 1318 - 1328
  • [10] INFLUENCE OF CALIBRATION MATERIALS IN SINGLE-ENERGY AND DUAL-ENERGY QUANTITATIVE CT
    STEENBEEK, JCM
    VANKUIJK, C
    GRASHUIS, JL
    RADIOLOGY, 1992, 183 (03) : 849 - 855