Dual-energy compared to single-energy CT in pediatric imaging: a phantom study for DECT clinical guidance

被引:23
|
作者
Zhu, Xiaowei [1 ,2 ]
McCullough, William P. [3 ]
Mecca, Patricia [1 ]
Servaes, Sabah [1 ,2 ]
Darge, Kassa [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch ofMedicine, Philadelphia, PA 19104 USA
[3] Univ Virginia Hlth Syst, Dept Radiol & Med Imaging, POB 800170, Charlottesville, VA 22908 USA
关键词
Children; Computed tomography; Dual-energy computed tomography; Radiation dose; LUNG PERFUSION; CHILDREN; QUALITY;
D O I
10.1007/s00247-016-3668-x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Dual-energy CT technology is available on scanners from several vendors and offers significant advantages over classic single-energy CT technology in multiple clinical applications. Many studies have detailed dual-energy CT applications in adults and several have evaluated the relative radiation dose performance of dual-energy CT in adult imaging. However, little has been published on dual-energy CT imaging in the pediatric population, and the relative dose performance of dual-energy CT imaging in the pediatric population is not well described. When evaluating dual-energy CT technology for implementation into a routine clinical pediatric imaging practice, the radiation dose implications must be considered, and when comparing relative CT dose performance, image quality must also be evaluated. Therefore the purpose of this study is to develop dual-energy CT scan protocols based on our optimized single-energy scan protocols and compare the dose. We scanned the head, chest and abdomen regions of pediatric-size anthropomorphic phantoms with contrast inserts, using our optimized single-energy clinical imaging protocols on a Siemens FlashA (R) CT scanner. We then scanned the phantoms in dual-energy mode using matching image-quality reference settings. The effective CT dose index volume (CTDIvol) of the scans was used as a surrogate for relative dose in comparing the single- and dual-energy scans. Additionally, we evaluated image quality using visual assessment and contrast-to-noise ratio. Dual-energy CT scans of the head and abdomen were dose-neutral for all three phantoms. Dual-energy CT scans of the chest showed a relative dose increase over the single-energy scan for 1- and 5-year-old child-based age-equivalent phantoms, ranging 11-20%. Quantitative analysis of image quality showed no statistically significant difference in image quality between the single-energy and dual-energy scans. There was no clinically significant difference in image quality by visual assessment. Dual-energy CT is dose-neutral in imaging the head and abdomen in children. It is not dose-neutral in chest imaging of very small children. With a better understanding of the dose consequences of converting single-energy protocols to dual-energy protocols we can begin to implement clinical dual-energy CT and utilize its unique capabilities in pediatric imaging.
引用
收藏
页码:1671 / 1679
页数:9
相关论文
共 50 条
  • [41] Accuracy of liver metastasis detection and characterization: Dual-energy CT versus single-energy CT with deep learning reconstruction
    Jensen, Corey T.
    Wong, Vincenzo K.
    Wagner-Bartak, Nicolaus A.
    Liu, Xinming
    Sobha, Renjith Padmanabhan Nair
    Sun, Jia
    Likhari, Gauruv S.
    Gupta, Shiva
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [42] Dual-energy CT for the detection of skull base invasion in nasopharyngeal carcinoma: comparison of simulated single-energy CT and MRI
    Zhan, Yang
    Wang, Peng
    Wang, Yuzhe
    Wang, Yin
    Tang, Zuohua
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [43] Dual-Energy Computed Tomography: Is There a Penalty in Image Quality and Radiation Dose Compared With Single-Energy Computed Tomography?
    Thomas, Christoph
    Ketelsen, Dominik
    Tsiflikas, Ilias
    Reimann, Anja
    Brodoefel, Harald
    Claussen, Claus D.
    Heuschmid, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 309 - 315
  • [44] Comparison of metal artifact reduction using single-energy CT and dual-energy CT with various metallic implants in cadavers
    Barreto, Izabella
    Pepin, Eric
    Davis, Ivan
    Dean, Cooper
    Massini, Tara
    Rees, John
    Olguin, Catherine
    Quails, Nathan
    Correa, Nathalie
    Rill, Lynn
    Arreola, Manuel
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [45] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [46] Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study
    Brinjikji, Waleed
    Michalak, Gregory
    Kadirvel, Ramanathan
    Dai, Daying
    Gilvarry, Michael
    Duffy, Sharon
    Kallmes, David F.
    McCollough, Cynthia
    Leng, Shuai
    INTERVENTIONAL NEURORADIOLOGY, 2017, 23 (03) : 279 - 284
  • [47] Deep learning from dual-energy information for whole-heart segmentation in dual-energy and single-energy non-contrast-enhanced cardiac CT
    Bruns, Steffen
    Wolterink, Jelmer M.
    Takx, Richard A. P.
    van Hamersvelt, Robbert W.
    Sucha, Dominika
    Viergever, Max A.
    Leiner, Tim
    Isgum, Ivana
    MEDICAL PHYSICS, 2020, 47 (10) : 5048 - 5060
  • [48] Quantification of Metal Artifact Reduction of Dual-Energy CT: A Phantom Study
    Li, K.
    Leung, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3036 - 3036
  • [49] Imaging the Spine with Dual-Energy CT
    Murray N.
    Le M.
    Ebrahimzadeh O.
    Alharthy A.
    Mohammed M.F.
    Ouellette H.A.
    Khosa F.
    Current Radiology Reports, 5 (9)
  • [50] Dual-energy CT and coronary imaging
    Kay, Fernando Uliana
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2020, 10 (04) : 1090 - 1107