INFLUENCE OF CALIBRATION MATERIALS IN SINGLE-ENERGY AND DUAL-ENERGY QUANTITATIVE CT

被引:14
|
作者
STEENBEEK, JCM
VANKUIJK, C
GRASHUIS, JL
机构
[1] ERASMUS UNIV,DEPT RADIOL,3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV,DEPT MED INFORMAT,3000 DR ROTTERDAM,NETHERLANDS
[3] ACAD HOSP ROTTERDAM,ROTTERDAM,NETHERLANDS
关键词
COMPUTED TOMOGRAPHY (CT); DUAL-ENERGY; SPINE; ANATOMY;
D O I
10.1148/radiology.183.3.1584946
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With single-energy (SE) quantitative computed tomography (CT), the density of bone mineral in the vertebral body can be estimated. With dual-energy (DE) quantitative CT, both bone-mineral density and fat content can be measured. The calibration device normally used contains materials mimicking trabecular bone, fat, and hematopoietic tissue. To evaluate the influence of different calibration materials on these estimates, theoretical CT numbers were calculated for the trabecular part of the vertebral body and for different calibration devices. Calibration devices were simulated; they contained either identical materials or various accepted tissue-mimicking materials. For all combinations, quantitative CT data were generated for the SE quantitative CT method and for two DE quantitative CT methods. Only one method provided accurate results under ideal circumstances. The selection of tissue-mimicking materials in the calibration devices is important for the interpretation of results of SE and DE quantitative CT. Errors of more than a factor 2 were found when different types of materials were used.
引用
收藏
页码:849 / 855
页数:7
相关论文
共 50 条
  • [1] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [2] A deep learning approach for dual-energy CT imaging using a single-energy CT data
    Zhao, Wei
    Lv, Tianling
    Gao, Peng
    Shen, Liyue
    Dai, Xianjin
    Cheng, Kai
    Jia, Mengyu
    Chen, Yang
    Xing, Lei
    [J]. 15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [3] Generation of Brain Dual-Energy CT from Single-Energy CT Using Deep Learning
    Liu, Chi-Kuang
    Liu, Chih-Chieh
    Yang, Cheng-Hsun
    Huang, Hsuan-Ming
    [J]. JOURNAL OF DIGITAL IMAGING, 2021, 34 (01) : 149 - 161
  • [4] Generation of Brain Dual-Energy CT from Single-Energy CT Using Deep Learning
    Chi-Kuang Liu
    Chih-Chieh Liu
    Cheng-Hsun Yang
    Hsuan-Ming Huang
    [J]. Journal of Digital Imaging, 2021, 34 : 149 - 161
  • [5] Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT)
    Shayan, Ramin Ghasemi
    Oladghaffari, Maryam
    Sajjadian, Fakhrosadat
    Ghaziyani, Mona Fazel
    [J]. RADIOLOGY RESEARCH AND PRACTICE, 2020, 2020
  • [6] Synthetic dual-energy CT reconstruction from single-energy CT Using artificial intelligence
    Jiwoong Jeong
    Andrew Wentland
    Domenico Mastrodicasa
    Ghaneh Fananapazir
    Adam Wang
    Imon Banerjee
    Bhavik N. Patel
    [J]. Abdominal Radiology, 2023, 48 : 3537 - 3549
  • [7] Generation of Dual-Energy CT Image Dataset From Single-Energy CT Image Dataset
    Dong, Y.
    Huo, J.
    Wang, X.
    Wang, P.
    Zhu, X.
    Feng, Y.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Synthetic dual-energy CT reconstruction from single-energy CT Using artificial intelligence
    Jeong, Jiwoong
    Wentland, Andrew
    Mastrodicasa, Domenico
    Fananapazir, Ghaneh
    Wang, Adam
    Banerjee, Imon
    Patel, Bhavik N.
    [J]. ABDOMINAL RADIOLOGY, 2023, 48 (11) : 3537 - 3549
  • [9] Robustness of CT radiomics features: consistency within and between single-energy CT and dual-energy CT
    Chen, Yong
    Zhong, Jingyu
    Wang, Lan
    Shi, Xiaomeng
    Lu, Wei
    Li, Jianying
    Feng, Jianxing
    Xia, Yihan
    Chang, Rui
    Fan, Jing
    Chen, Liwei
    Zhu, Ying
    Yan, Fuhua
    Yao, Weiwu
    Zhang, Huan
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (08) : 5480 - 5490
  • [10] Robustness of CT radiomics features: consistency within and between single-energy CT and dual-energy CT
    Yong Chen
    Jingyu Zhong
    Lan Wang
    Xiaomeng Shi
    Wei Lu
    Jianying Li
    Jianxing Feng
    Yihan Xia
    Rui Chang
    Jing Fan
    Liwei Chen
    Ying Zhu
    Fuhua Yan
    Weiwu Yao
    Huan Zhang
    [J]. European Radiology, 2022, 32 : 5480 - 5490