Obtaining dual-energy computed tomography (CT) information from a single-energy CT image for quantitative imaging analysis of living subjects by using deep learning

被引:0
|
作者
Zhao, Wei [1 ]
Lv, Tianling [2 ]
Lee, Rena [3 ]
Chen, Yang [2 ]
Xing, Lei [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Palo Alto, CA 94306 USA
[2] Southeast Univ, Dept Comp Sci & Engn, Nanjing 210096, Jiangsu, Peoples R China
[3] Ehwa Womens Univ, Dept Bioengn, Seoul, South Korea
关键词
Dual-energy computed tomography; Single-energy computed tomography; Deep learning; Convolutional neural network; Material decomposition; Virtual non-contrast; Iodine quantification; PRINCIPLES;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Computed tomographic (CT) is a fundamental imaging modality to generate cross-sectional views of internal anatomy in a living subject or interrogate material composition of an object, and it has been routinely used in clinical applications and nondestructive testing. In a standard CT image, pixels having the same Hounsfield Units (HU) can correspond to different materials, and it is therefore challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable to differentiate multiple materials, but the costly DECT scanners are not widely available as single-energy CT (SECT) scanners. Recent advancement in deep learning provides an enabling tool to map images between different modalities with incorporated prior knowledge. I [ere we develop a deep learning approach to perform DECT imaging by using the standard SECT data. The end point of the approach is a model capable of providing the high-energy CT image for a given input low-energy CT image. The feasibility of the deep learning-based DECT imaging method using a SECT data is demonstrated using contrast-enhanced DECT images and evaluated using clinical relevant indexes. This work opens new opportunities for numerous DECT clinical applications with a standard SECT data and may enable significantly simplified hardware design, scanning dose and image cost reduction for future DECT systems.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 50 条
  • [41] Utility of single-energy and dual-energy computed tomography in clot characterization: An in-vitro study
    Brinjikji, Waleed
    Michalak, Gregory
    Kadirvel, Ramanathan
    Dai, Daying
    Gilvarry, Michael
    Duffy, Sharon
    Kallmes, David F.
    McCollough, Cynthia
    Leng, Shuai
    INTERVENTIONAL NEURORADIOLOGY, 2017, 23 (03) : 279 - 284
  • [42] New Applications of Cardiac Computed Tomography Dual-Energy, Spectral, and Molecular CT Imaging
    Danad, Ibrahim
    Fayad, Zahi A.
    Willemink, Martin J.
    Min, James K.
    JACC-CARDIOVASCULAR IMAGING, 2015, 8 (06) : 710 - 723
  • [43] Deep learning reconstruction CT for liver metastases: low-dose dual-energy vs standard-dose single-energy
    Peijie Lyu
    Zhen Li
    Yan Chen
    Huixia Wang
    Nana Liu
    Jie Liu
    Pengchao Zhan
    Xing Liu
    Bo Shang
    Luotong Wang
    Jianbo Gao
    European Radiology, 2024, 34 : 28 - 38
  • [44] Deep learning reconstruction CT for liver metastases: low-dose dual-energy vs standard-dose single-energy
    Lyu, Peijie
    Li, Zhen
    Chen, Yan
    Wang, Huixia
    Liu, Nana
    Liu, Jie
    Zhan, Pengchao
    Liu, Xing
    Shang, Bo
    Wang, Luotong
    Gao, Jianbo
    EUROPEAN RADIOLOGY, 2024, 34 (01) : 28 - 38
  • [45] Feasibility of Using Deep Learning to Generate Dual-Energy CT from 120-kV CT
    Tung, Chi-Hsiang
    Liu, Chi-Kuang
    Huang, Hsuan-Ming
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2023, 43 (01) : 93 - 101
  • [46] Feasibility of Using Deep Learning to Generate Dual-Energy CT from 120-kV CT
    Chi-Hsiang Tung
    Chi-Kuang Liu
    Hsuan-Ming Huang
    Journal of Medical and Biological Engineering, 2023, 43 : 93 - 101
  • [47] Synthetic Dual Energy CT Imaging from Single Energy CT Using Deep Attention Neural Network
    Wang, Tonghe
    Charyyev, Serdar
    Lei, Yang
    Ghavidel, Beth
    Beitler, Jonathan J.
    McDonald, Mark
    Curran, Walter J.
    Zhou, Jun
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [48] Pseudo dual-energy CT-derived iodine mapping using single-energy CT data based on a convolution neural network
    Yuasa, Yuki
    Shiinoki, Takehiro
    Fujimoto, Koya
    Tanaka, Hidekazu
    BJR OPEN, 2023, 5 (01):
  • [49] Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
    Li, Bin
    Ni, Jianming
    Chen, Fangming
    Lu, Fengqi
    Zhang, Lei
    Wu, Wenjuan
    Zhang, Zhuiyang
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 11
  • [50] Physics-informed Deep Learning for Dual-Energy Computed Tomography Image Processing
    Maarten G. Poirot
    Rick H. J. Bergmans
    Bart R. Thomson
    Florine C. Jolink
    Sarah J. Moum
    Ramon G. Gonzalez
    Michael H. Lev
    Can Ozan Tan
    Rajiv Gupta
    Scientific Reports, 9